DATI TECNICI GENERALI
HM
I
Dati elettric
i
Corrente nominale assorbita (1)
Numero
Circuiti
Refrigerante
Carica refrigerante totale (2)
GWP
CO2 equivalente
Scambiatore lato utenza
Tipo
Numero
Attacchi (in/out)
Diametro (in)
HMI080
HMI100
HMI100T
HMI120
HMI120T
HMI140
HMI140T
HMI160
HMI160T
A
10,4
23,0
12,0
25,0
12,0
29,0
12,0
29,0
12,
0
Compressor
e
Tipo
tipo
Rotary D
C
Rotary DC
Rotary D
C
Rotary DC
Rotary D
C
Rotary DC
Rotary DC
Rotary DC
Rotary D
C
Inverte
r
Inverte
r
Inverte
r
Inverte
r
Inverte
r
Inverte
r
Inverte
r
Inverte
r
Inverte
r
n°
1
1
1
1
1
1
1
1
1
n°
1
1
1
1
1
1
1
1
1
tipo
R32
R32
R32
R32
R32
R32
R32
R32
R32
kg
0,90
2,20
2,20
2,20
2,20
2,20
2,20
2,20
2,20
675,0
675,0
675,0
675,0
675,0
675,0
675,0
675,0
675,0
tCO2eq
0,61
1,49
1,49
1,49
1,49
1,49
1,49
1,49
1,49
tipo
Piastre
Piastre
Piastre
Piastre
Piastre
Piastre
Piastre
Piastre
Piastre
n°
1
1
1
1
1
1
1
1
1
Tipo
Gas femmina Gas femmina Gas femmina Gas femmina Gas femmina Gas femmina Gas femmina Gas femmina Gas femmina
Ø
1”
1”
1”
1”
1”
1”
1”
1”
1
”
Ø
1”
1”
1”
1”
1”
1”
1”
1”
1”
tipo
Assiale
Assiale
Assiale
Assiale
Assiale
Assiale
Assiale
Assiale
Assiale
tipo
Inverter
Inverter
Inverter
Inverter
Inverter
Inverter
Inverter
Inverter
Inverte
r
n°
1
1
1
1
1
1
1
1
1
m³/h
2.600
4.500
4.500
4.500
4.500
4.500
4.500
4.500
4.500
dB(A)
53,0
56,0
56,0
56,0
56,0
57,0
57,0
59,0
59,0
dB(A)
65,0
69,0
69,0
69,0
69,0
70,0
70,0
72,0
72,0
dB(A)
51,0
54,0
54,0
54,0
54,0
55,0
55,0
57,0
57,0
Alimentazione
V/Ph/Hz 220-240V
~
50H
z
220-240V ~
50H
z
380-415V 3N
~
50H
z
220-240V ~
50Hz
380-415V 3N
~
50Hz
220-240V
~
50H
z
380-415V 3N
~
50H
z
220-240V ~
50Hz
380-415V 3N
~
50H
z
(1)
(2)
La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.
La carica riportata in tabella è un valore stimato e preliminare. Il valore finale della carica di refrigerante è riportato nella targhetta tecnica dell'unità. Per maggiori informazioni contattare sede
.
HMI_1
Diametro (out)
Ventilatore
Tipo
A
R
I
A
-
A
C
Q
U
A
Motore ventilatore
Numero
Portata aria
Dati sonori misurati in funzionamento a fredd
o
Pressione sonora (1 m)
Dati sonori misurati in funzionamento a cald
o
Potenza sonora
Pressione sonora (1 m)
Alimentazion
e
Dati elettric
i
Corrente nominale assorbita (1)
Numero
Circuiti
Refrigerante
Carica refrigerante totale (2)
GWP
CO2 equivalente
Scambiatore lato utenza
Tipo
Numero
Alimentazion
e
(1)
(2)
HMI041 HMI061 HMI081 HMI081T HMI101 HMI101T HMI121 HMI121T HMI141 HMI141T HMI161 HMI161
T
A
11,0
11,0
23,0
8,0
25,0
9,0
29,0
11,5
30,0
12,0
30,0
12,
5
Compressor
e
Tipo
tipo
Rotativ
o
Rotativo
Rotativo
Rotativ
o
Rotativo
Rotativo
Rotativo
Rotativ
o
Rotativ
o
Rotativ
o
Rotativo
inverter
inverte
r
inverte
r
inverte
r
inverter
inverte
r
inverte
r
inverter
inverter
inverte
r
inverte
r
Rotativ
o
inverter
n°
1
1
1
1
1
1
1
1
1
1
1
1
n°
1
1
1
1
1
1
1
1
1
1
1
1
tipo
R32
R32
R32
R32
R32
R32
R32
R32
R32
R32
R32
R32
kg
0,95
0,95
1,60
1,60
1,60
1,60
2,20
2,20
2,20
2,20
2,20
2,20
675,0
675,0
675,0
675,0
675,0
675,0
675,0
675,0
675,0
675,0
675,0
675,
0
tCO2eq
0,64
0,64
1,08
1,08
1,08
1,08
1,49
1,49
1,49
1,49
1,49
1,49
tipo
Piastre
Piastre
Piastre
Piastre
Piastre
Piastre
Piastre
Piastre
Piastre
Piastre
Piastre
Piastr
e
n°
1
1
1
1
1
1
1
1
1
1
1
1
Attacchi (in/out)
Tipo
Ga
s
Gas
femmin
a
femmina
Ga
s
femmin
a
Ga
s
Ga
s
Ga
s
Ga
s
Ga
s
Ga
s
Ga
s
Ga
s
femmin
a
femmina
femmin
a
femmin
a
femmin
a
femmin
a
femmin
a
femmina
Ga
s
femmina
Ø
1”
1”
1”
1”
1”
1”
1”
1”
1”
1”
1”
1”
Ø
1”
1”
1”
1”
1”
1”
1”
1”
1”
1”
1”
1”
tipo
Assiale
Assiale
Assiale
Assiale
Assiale
Assiale
Assiale
Assiale
Assiale
Assiale
Assiale
Assiale
tipo
Inverter
Inverter
Inverter
Inverter
Inverter
Inverter
Inverter
Inverter
Inverter
Inverter
Inverter
Inverter
n°
1
1
1
1
1
1
1
1
1
1
1
1
m³/h
3.200
3.200
5.800
5.800
5.800
5.800
5.051
5.051
5.051
5.051
5.051
5.051
dB(A)
58,0
58,0
68,0
68,0
68,0
68,0
68,0
68,0
68,0
68,0
68,0
68,
0
dB(A)
52,0
53,0
56,0
56,0
56,0
56,0
58,0
58,0
59,0
59,0
59,0
59,0
Alimentazione
V/Ph/Hz 230V ~
50Hz
230V ~
50H
z
230V
~
50Hz
400V 3N ~
50H
z
230V ~
50Hz
400V 3N
~
50Hz
230V
~
50H
z
400V 3N ~
50H
z
230V
~
50H
z
400V 3N
~
50Hz
230V
~
50H
z
400V 3N
~
50Hz
La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.
La carica riportata in tabella è un valore stimato e preliminare. Il valore
finale della carica di refrigerante è riportato nella targhetta tecnica dell'unità. Per maggiori informazioni contattare sede
.
Diametro (in)
Diametro (out)
Ventilatore
Tipo
Motore ventilatore
Numero
Portata aria
Dati sonori misurati in funzionamento a caldo
Potenza sonora
Pressione sonora (1 m)
352
www.aermec.com
HMI-HMI1-HP_I_UN50_00