EI: Pumps with frequency converter

The NR(D) EI, NR4 EI, pumps are available with power from 0,25 kW up to 22 kW, the pumps are equipped with I-MAT installed on board

.

This design enables the creation of a highly compact and e

fficient variable-speed system, making them ideal for water supply applications and the distribution o

f

hot and cold water

.

The pump is

fitted with transducers optimized for operation and is pre-programmed at the factory for seamless performance.

Feature

s

•

•

•

•

•

Energy saving

Compact design

Easy to use

Programmable to suit the system requirements

Reliability

Standard executio

n

• The system consists of:

• Pump

• Induction motor (2 for NRD, NRD4)

• I-MAT Frequency converter (2 for NRD, NRD4)

• Motor adapter for the motor mounting of the frequency converter (2 for NRD, NRD4)

• Connection cable between frequency converter and induction motor

• Single pressure transducer for 2 poles and differential transducer for 4 poles

• - Communication cable for cascade mode for NRD, NRD4

• - 2 Cascade mode expansion board for NRD, NRD4

Main feature

s

Rated motor power output from 0,25 kW to 22 kW.

Control range from 1750 to 3450 rpm (2-pole)

Control range 870÷1750 1/rpm (4-pole

)

Protection against dry running

Protection against operations with closed valve ports

Protection against system leakages

Protection against overcurrent in the motor

Protection agains overvoltage and undervoltage of the power suppl

y

Protection against current unbalances between phases

Operating mode

s

Constant pressure mode

with pressure transduce

r

In this mode, the system maintains the preset pressure regardless of changes in the

flow demand of the installation

.

Proportional pressure mode

with pressure transducer

In this mode the system changes the working pressure according to the required

flow rate.

Constant flow mode

with

flow meter

pressure

.

In this mode, the system maintains a constant flow rate at a specific point in the installation, adjusted according to the require

d

Fixed speed mode

with setting of the speed preferential rotation.

In this mode, by changing the working frequency, you may choose any operational curve included within the working range

.

H

H

H

H

+

-

+

-

Q

+

-

Q

ma

x

+

-

min

Q

Constant temperature mod

e

with temperature transduce

r

In this mode the system keeps the temperature constant inside a system by changing the speed of the pump

.