IN POMPA DI CALORE - UNIT

À ESTERNE MODULARI

KXZ2

COLLEGA FINO A 80 UNIT

À INTERNE/130% DELLA CAPACIT

FDC 1200 KXZE2 (FDC 400+FDC 400+FDC 400) 120,0 kW

FDC 1250 KXZE2 (FDC 400+FDC 400+FDC 450) 125,0 kW

FDC 1300 KXZE2 (FDC 400+FDC 450+FDC 450) 130,0 kW

FDC 1350 KXZE2 (FDC 450+FDC 450+FDC 450) 135,0 kW

FDC 1425 KXZE2 (FDC 475+FDC 475+FDC 475) 142,5 kW

CARATTERISTICHE

Massima ef

ficienza energetica: COP 4,40 e EER 3,64 [42 HP]

Solo compressori DC Inverter

Splittaggio elevato: fino a 1000 m totali e con una distanza

massima tra U.E. e la U.I. più lontana di 160 m

FDC 1450 KXZE2 (FDC 475+FDC 475+FDC 500) 145,0 kW

FDC 1500 KXZE2 (FDC 500+FDC 500+FDC 500) 150,0 kW

FDC 1560 KXZE2 (FDC 500+FDC 500+FDC 560) 156,0 kW

FDC 1620 KXZE2 (FDC 500+FDC 560+FDC 560) 162,0 kW

FDC 1680 KXZE2 (FDC 560+FDC 560+FDC 560) 168,0 kW

RANGE DI FUNZIONAMENTO

Fino a 85 Pa di prevalenza sui ventilatori

COMBINAZIONI

Modello unità esterna

Combinazioni

Classe di potenza

Capacità nominale

Potenza assorbita nominale

Coefficiente di efficienza energetica nominale

Capacità nominale

Potenza assorbita nominale

Coefficiente di prestazione energetica nominale

Dati elettrici

Alimentazione

Corrente nominale

Corrente massima

Dati circuito frigorifero

42~60HP

(120,0~168,0 kW)

FDC1200KXZE2 FDC1250KXZE2 FDC1300KXZE2 FDC1350KXZE2 FDC1425KXZE2 FDC1450KXZE2 FDC1500KXZE2 FDC1560KXZE2 FDC1620KXZE2 FDC1680KXZE2

FDC400KXZE2 FDC400KXZE2 FDC400KXZE2 FDC450KXZE2 FDC475KXZE2 FDC475KXZE2 FDC500KXZE2 FDC500KXZE2 FDC500KXZE2 FDC560KXZE2

Refrigerante2

Quantit

à pre-carica refrigerante3 (tonnellate di CO2 equivalenti)

R410A (2088)

34,5 (72,036) 34,5 (72,036)

3/4” (19,05) 3/4” (19,05)

1-1/2” (38,1) 1-1/2” (38,1)

3/8” (9,52) 3/8” (9,52)

2052x4050x720

Diametro tubazioni4

Specifiche Prodotto

Dimensioni

Peso netto

Unit

à interne collegabili5

Liquido

Gas

Bilanciamento olio

Raffrescamento

Riscaldamento

Raffrescamento

Riscaldamento

42

120,00

32,94

3,64

135,00

30,68

4,40

52,80

50,10

96,00

34,5 (72,036)

3/4” (19,05)

1-1/2” (38,1)

3/8” (9,52)

996

3 ~ 80

50 ~ 130

44

125,00

35,94

3,48

140,00

32,95

4,25

57,60

53,80

96,00

34,5 (72,036)

3/4” (19,05)

1-1/2” (38,1)

3/8” (9,52)

996

3 ~ 80

50 ~ 130

46

130,00

38,93

3,34

145,00

35,23

4,12

62,40

57,50

96,00

34,5 (72,036)

3/4” (19,05)

1-1/2” (38,1)

3/8” (9,52)

996

3 ~ 80

50 ~ 130

135,00

41,93

3,22

150,00

37,50

4,00

67,20

61,20

96,00

34,5 (72,036)

3/4” (19,05)

1-1/2” (38,1)

3/8” (9,52)

996

3 ~ 80

50 ~ 130

142,50

41,91

3,40

159,00

38,97

4,08

145,00

41,95

3,46

162,00

39,54

4,10

56

156,00

45,52

3,43

175,00

43,27

4,04

72,10

69,90

120,60

34,5 (72,036)

3/4” (19,05)

1-1/2” (38,1)

3/8” (9,52)

1134

3 ~ 80

50 ~ 130

58

162,00

49,01

3,31

182,00

45,87

3,97

76,40

74,10

120,60

34,5 (72,036)

3/4” (19,05)

1-1/2” (38,1)

3/8” (9,52)

1134

3 ~ 80

50 ~ 130

HxLxP

mm

Min ~ Max

Capacità

kg

%

1134

3 ~ 80

50 ~ 130

1134

3 ~ 80

50 ~ 130

HP

kW

kW

EER1

kW

kW

COP1

Ph-V-Hz

A

A

A

tipo (GWP)

kg

inch (mm)

FDC400KXZE2 FDC400KXZE2 FDC450KXZE2

FDC400KXZE2 FDC450KXZE2 FDC450KXZE2

FDC450 KXZE2 FDC 475 KXZE2 FDC 475 KXZE2

FDC450KXZE2 FDC475KXZE2 FDC500KXZE2

48

50

52

FDC 500 KXZE2

FDC500KXZE2

54

150,00

42,03

3,57

168,00

40,68

4,13

67,80

65,70

120,60

34,5 (72,036)

3/4” (19,05)

1-1/2” (38,1)

3/8” (9,52)

1134

3 ~ 80

50 ~ 130

FDC 500 KXZE2 FDC 560 KXZE2

FDC560KXZE2 FDC560KXZE2

FDC 560 KXZE2

FDC560KXZE2

60

168,00

52,50

3,20

189,00

48,46

3,90

80,70

78,30

120,60

34,5 (72,036)

3/4” (19,05)

1-1/2” (38,1)

3/8” (9,52)

1134

3 ~ 80

50 ~ 130

1. Valore misurato secondo la norma armonizzata EN14511. 2. La perdita di refrigerante contribuisce al cambiamento climatico. In caso di rilascio nell’atmosfera, i refrigeranti con un potenziale di riscaldamento globale (GWP) più basso contribuiscono in misura minore al riscaldamento globale rispetto

a quelli con un GWP pi

ù elevato. Questo apparecchio contiene un fluido refrigerante con un GWP di 2088. Se 1 kg di questo fluido refrigerante fosse rilasciato nell’atmosfera, quindi, l’impatto sul riscaldamento globale sarebbe 2088 volte più elevato rispetto a 1 kg di CO2 , per un periodo di 100 anni.

In nessun caso l’utente deve cercare di intervenire sul circuito refrigerante o di disassemblare il prodotto. In caso di necessit

à occorre sempre rivolgersi a personale qualificato. 3. Per il calcolo della carica addizionale di refrigerante fare riferimento alle etichette posizionate all'interno e all'esterno

dell'unità. 4. I diametri indicati sono riferiti al tratto fino alla prima derivazione, con una lunghezza equivalente inferiore ai 90 m. 5. Quando si collegano unit

à interne di tipo FDK, FDFL, FDFU o FDFW il limite massimo scende al 130%.

126

3Ph-380~415V-50Hz

67,80

63,00

120,60

67,80

63,90

120,60

S

I

S

T

E

M

I

V

R

F