DETRAZIONI

FISCALI

65%

CONTO

TERMICO

2.0

IOZ-R32 + ICZ-R32

GARANZIA

CODICE PRODOTTO

U.E.

IOZ-70M-R32

IOZ-88M-R32

IOZ-105M-R32

IOZ-105T-R32

IOZ-140T-R32

U.I.

ICZ-70-R32

ICZ-88-R32

ICZ-105-R32

ICZ-105-R32

ICZ-140-R32

INCENTIVI E DETRAZIONI

65%

-

C.T.

-

Alimentazione elettrica U.E.

Alimentazione elettrica U.I.

V/Ph/Hz

V/Ph/Hz

Btu/h

kW

W

A

W/W

Btu/h

kW

W

A

220-240V/1Ph/50Hz

220-240V/1Ph/50Hz

24000 (11263~27000)

7.03 (3.30~7.91)

2143 (780~2748)

9.3 (4.2~12)

3.28

26000 (9577~30500)

7.62 (2.81~8.94)

1900 (610~2700)

8.3 (3.6~12.1)

4.01

7.00

6.20

A++

395

6.00

4.00

A+

2100

-7

-15

830x830x205

910x910x250

950x950x55

1035x1035x90

21.6/25.4

6/9

1300/1140/1000

45.5/42.5/39.5/27

220-240V/1Ph/50Hz

220-240V/1Ph/50Hz

30000 (7600~32000)

8.79 (2.23~9.38)

2721 (890~3000)

11.8 (2.0~13.0)

3.23

32000 (9200~33200)

9.38 (2.70~9.73)

2450 (430~2550)

10.6 (3.0~11.5)

3.83

8.80

6.60

A++

467

7.40

4.20

A+

2467

-7

-15

830x830x245

910x910x290

950x950x55

1035x1035x90

24.6/28.6

6/9

1720/1550/1400

49.5/47/44/38.5

220-240V/1Ph/50Hz

220-240V/1Ph/50Hz

36000 (9200~39000)

10.55 (2.70~11.43)

3270 (900~4200)

14.2 (4.2~18.5)

3.23

38000 (9500~42000)

11.14 (2.78~12.30)

3000 (800~3950)

13.0 (3.5~17.5)

3.71

10.50

6.70

A++

549

8.50

4.00

380-415V/3Ph/50Hz

220-240V/1Ph/50Hz

36000 (9200~39000)

10.55 (2.70~11.43)

3270 (890~4150)

6.5 (1.4~6.5)

3.23

38000 (9500~43200)

11.14 (2.78~12.66)

3000 (780~4000)

5.0 (1.3~6.4)

3.71

10.50

6.40

A++

574

8.20

4.00

380-415V/3Ph/50Hz

220-240V/1Ph/50Hz

48000 (12000~54000)

14.07 (3.52~15.83)

4650 (800~5900)

8.1 (1.8~10.2)

3.03

55000 (14000~59000)

16.12 (4.10~17.29)

4580 (900~5500)

8.0 (1.9~9.5)

3.52

14.00

6.10

A++

803

11.00

4.00

Raffreddamento

(Min~Max)

Capacità

Potenza assorbita nominale

Corrente assorbita nominale

EER

Capacità

Potenza assorbita nominale

Corrente assorbita nominale

Riscaldamento

(Min~Max)

Indice di

efficienza

energetica

stagionale in

raffreddamento

Indice di

efficienza

energetica

stagionale in

riscaldamento

(clima

temperato)

Temperatura limite

Unità interna

COP

W/W

Carico termico (Pdesignc)

kW

SEER

W/W

Classe di efficienza energetica

Consumo energetico annuo

Carico termico (Pdesignh)

kWh/a

kW

SCOP

W/W

Classe di efficienza energetica

Consumo energetico annuo

Temperatura bivalente Tbiv

di esercizio (Tol)

Dimensioni (LxPxA)

Imballo (LxPxA)

Dimensioni pannello (LxPxA)

Imballo pannello (LxPxA)

Peso netto/Peso lordo

Peso netto/Peso lordo pannello

A+

A+

A+

Portata aria unità interna (Max/Med/Min)

Livello pressione sonora unità interna (Max/Med/Min)

Livello potenza sonora unità interna (Max)

Dimensioni (LxPxA)

Unità esterna

Imballo (LxPxA)

Peso netto/Peso lordo

Portata aria unità esterna

Livello pressione sonora unità esterna

Livello potenza sonora unità esterna

Tipo

GWP (effetto serra)

Quantità caricata

Valore CO

2

Lato liquido

Lato gas

Lunghezza delle tubazioni (Max)

Lunghezza delle tubazioni (Min)

Dislivello massimo U.I. e U.E.

Precarica di gas refrigerante

Incremento di refrigerante

kWh/a

°C

°C

mm

mm

mm

mm

Kg

Kg

m

3

/h

dB(A)

dB(A)

mm

mm

Kg

m

3

/h

dB(A)

dB(A)

Kg

tCO

2

mm (inch)

mm (inch)

m

m

m

m

g/m

mm

°C

°C

°C

2975

-7

-15

830x830x245

910x910x290

950x950x55

1035x1035x90

27.2/31.2

6/9

1700/1550/1380

50/47.5/44.5/39

2870

-7

-15

830x830x245

910x910x290

950x950x55

1035x1035x90

27.2/31.2

6/9

1800/1600/1400

50/47.5/44.5/39

3850

-7

-15

830x830x287

910x910x330

950x950x55

1035x1035x90

29.3/33.5

6/9

1970/1780/1580

51/48.5/46.5/37.5

57

63

63

63

65

890x342x673

946x410x810

946x410x810

946x410x810

952x415x1333

995x398x740

1090x500x865

1090x500x885

1090x500x885

1095x495x1480

43.9/46.9

52.8/57.3

66.9/71.5

80.5/85

103.7/118.3

3500

3800

4000

4000

7500

60

62

63

63

63.5

67

70

70

70

73

Refrigerante

Tubazione

frigorifera

R32

675

1.50

1.013

Ø9.52 (3/8")

Ø15.9 (5/8")

50

3

25

5

24

OD Ø25

4 fili+terra

Telecomando

+16~+30

-15~+50

-15~+24

R32

675

2.00

1.350

Ø9.52 (3/8")

Ø15.9 (5/8")

50

3

25

5

24

OD Ø25

4 fili+terra

Telecomando

+16~+30

-15~+50

-15~+24

R32

675

2.40

1.620

Ø9.52 (3/8")

Ø15.9 (5/8")

75

3

30

5

24

OD Ø25

4 fili+terra

Telecomando

+16~+30

-15~+50

-15~+24

R32

675

2.40

1.620

Ø9.52 (3/8")

Ø15.9 (5/8")

75

3

30

5

24

OD Ø25

4 fili+terra

Telecomando

+16~+30

-15~+50

-15~+24

R32

675

2.80

1.890

Ø9.52 (3/8")

Ø15.9 (5/8")

75

3

30

5

24

OD Ø25

4 fili+terra

Telecomando

+16~+30

-15~+50

-15~+24

Diametro tubazioni drenaggio acqua

Cavo di comunicazione fra U.I. e U.E.

Tipo di controllo

Unità interna

Temperature di

Unità esterna (Raffred.)

esercizio

Unità esterna (Riscald.)

Valore di EER e COP misurato secondo la norma armonizzata EN14511. Valore di SEER misurato secondo la norma armonizzata EN14825. Regolamento UE N.206/2012. La perdita di refrigerante contribuisce al cambiamento climatico. In caso di rilascio nell’atmosfera. i

refrigeranti con un potenziale di riscaldamento globale (GWP) più basso contribuiscono in misura minore al riscaldamento globale rispetto a quelli con un GWP pi

ù elevato. Questo apparecchio contiene un fluido refrigerante con un GWP di 675. Se 1 Kg di questo fluido refrigerante

fosse rilasciato nell’atmosfera. quindi. l’impatto sul riscaldamento globale sarebbe 675 volte più elevato rispetto a 1 Kg di CO2. per un periodo di 100 anni. In nessun caso l’utente deve cercare di intervenire sul circuito refrigerante o di disassemblare il prodotto. In caso di necessità

occorre sempre rivolgersi a personale qualificato. Consumo di energia (kWh/anno) in base ai risultati di prove standard. Il consumo effettivo dipende dalle modalit

à di utilizzo dell’apparecchio e dal luogo in cui è installato. EER/COP dichiarati solo al fine delle detrazioni fiscali in

vigore all’atto della realizzazione di questa pubblicazione. Condizioni di test: PdesignC = Carico termico teorico in raffreddamento con temperatura esterna di 35°C (BS)/24°C (BU) e temperatura interna di 27°C (BS)/19°C (BU). PdesignH = Carico termico teorico in riscaldamento

con temperatura esterna di -10°C (BS)/-11°C (BU) e temperatura interna di 20°C (BS)/15°C (BU). Raffreddamento = Temperatura aria interna di 27°C (BS)/19°C (BU) e temperatura aria esterna di 35°C (BS)/24°C (BU). Riscaldamento = Temperatura aria interna di 20°C (BS)/15°C

(BU) e temperatura aria esterna di 7°C (BS)/6°C (BU). I livelli sonori sono misurati in una camera semi-anecoica. in una posizione di 1 m davanti all’unità e 1.3 m dal pavimento.

Le immagini dei prodotti sono da considerarsi come puramente indicative. Per maggiori informazioni far riferimento alle schede tecniche. Per la politica di continuo

miglioramento dei prodotti perseguita da IDEMA®. le caratteristiche sopra riportate sono soggette a modifiche senza alcun obbligo di preavviso.

45