DETRAZIONI
FISCALI
CONTO
TERMICO
2.0
GARANZIA
CODICE PRODOTTO
U.E.
IOZ-70M-R32
IOZ-88M-R32
IOZ-105M-R32
IOZ-105T-R32
IOZ-140T-R32
U.I.
ICZ-70-R32
ICZ-88-R32
ICZ-105-R32
ICZ-105-R32
ICZ-140-R32
INCENTIVI E DETRAZIONI
65%
√
√
√
√
-
C.T.
√
√
√
√
-
Alimentazione elettrica U.E.
Alimentazione elettrica U.I.
V/Ph/Hz
V/Ph/Hz
Btu/h
kW
W
A
W/W
Btu/h
kW
W
A
220-240V/1Ph/50Hz
220-240V/1Ph/50Hz
24000 (11263~27000)
7.03 (3.30~7.91)
2143 (780~2748)
9.3 (4.2~12)
3.28
26000 (9577~30500)
7.62 (2.81~8.94)
1900 (610~2700)
8.3 (3.6~12.1)
4.01
7.00
6.20
A++
395
6.00
4.00
A+
2100
-7
-15
830x830x205
910x910x250
950x950x55
1035x1035x90
21.6/25.4
6/9
1300/1140/1000
45.5/42.5/39.5/27
220-240V/1Ph/50Hz
220-240V/1Ph/50Hz
30000 (7600~32000)
8.79 (2.23~9.38)
2721 (890~3000)
11.8 (2.0~13.0)
3.23
32000 (9200~33200)
9.38 (2.70~9.73)
2450 (430~2550)
10.6 (3.0~11.5)
3.83
8.80
6.60
A++
467
7.40
4.20
A+
2467
-7
-15
830x830x245
910x910x290
950x950x55
1035x1035x90
24.6/28.6
6/9
1720/1550/1400
49.5/47/44/38.5
220-240V/1Ph/50Hz
220-240V/1Ph/50Hz
36000 (9200~39000)
10.55 (2.70~11.43)
3270 (900~4200)
14.2 (4.2~18.5)
3.23
38000 (9500~42000)
11.14 (2.78~12.30)
3000 (800~3950)
13.0 (3.5~17.5)
3.71
10.50
6.70
A++
549
8.50
4.00
380-415V/3Ph/50Hz
220-240V/1Ph/50Hz
36000 (9200~39000)
10.55 (2.70~11.43)
3270 (890~4150)
6.5 (1.4~6.5)
3.23
38000 (9500~43200)
11.14 (2.78~12.66)
3000 (780~4000)
5.0 (1.3~6.4)
3.71
10.50
6.40
A++
574
8.20
4.00
380-415V/3Ph/50Hz
220-240V/1Ph/50Hz
48000 (12000~54000)
14.07 (3.52~15.83)
4650 (800~5900)
8.1 (1.8~10.2)
3.03
55000 (14000~59000)
16.12 (4.10~17.29)
4580 (900~5500)
8.0 (1.9~9.5)
3.52
14.00
6.10
A++
803
11.00
4.00
Raffreddamento
(Min~Max)
Capacità
Potenza assorbita nominale
Corrente assorbita nominale
EER
Capacità
Potenza assorbita nominale
Corrente assorbita nominale
Riscaldamento
(Min~Max)
Indice di
efficienza
energetica
stagionale in
raffreddamento
Indice di
efficienza
energetica
stagionale in
riscaldamento
(clima
temperato)
Temperatura limite
Unità interna
COP
W/W
Carico termico (Pdesignc)
kW
SEER
W/W
Classe di efficienza energetica
Consumo energetico annuo
Carico termico (Pdesignh)
kWh/a
kW
SCOP
W/W
Classe di efficienza energetica
Consumo energetico annuo
Temperatura bivalente Tbiv
di esercizio (Tol)
Dimensioni (LxPxA)
Imballo (LxPxA)
Dimensioni pannello (LxPxA)
Imballo pannello (LxPxA)
Peso netto/Peso lordo
Peso netto/Peso lordo pannello
A+
A+
A+
Portata aria unità interna (Max/Med/Min)
Livello pressione sonora unità interna (Max/Med/Min)
Livello potenza sonora unità interna (Max)
Dimensioni (LxPxA)
Unità esterna
Imballo (LxPxA)
Peso netto/Peso lordo
Portata aria unità esterna
Livello pressione sonora unità esterna
Livello potenza sonora unità esterna
Tipo
GWP (effetto serra)
Quantità caricata
Valore CO
2
Lato liquido
Lato gas
Lunghezza delle tubazioni (Max)
Lunghezza delle tubazioni (Min)
Dislivello massimo U.I. e U.E.
Precarica di gas refrigerante
Incremento di refrigerante
kWh/a
°C
°C
mm
mm
mm
mm
Kg
Kg
m
3
/h
dB(A)
dB(A)
mm
mm
Kg
m
3
/h
dB(A)
dB(A)
Kg
tCO
2
mm (inch)
mm (inch)
m
m
m
m
g/m
mm
n°
°C
°C
°C
2975
-7
-15
830x830x245
910x910x290
950x950x55
1035x1035x90
27.2/31.2
6/9
1700/1550/1380
50/47.5/44.5/39
2870
-7
-15
830x830x245
910x910x290
950x950x55
1035x1035x90
27.2/31.2
6/9
1800/1600/1400
50/47.5/44.5/39
3850
-7
-15
830x830x287
910x910x330
950x950x55
1035x1035x90
29.3/33.5
6/9
1970/1780/1580
51/48.5/46.5/37.5
57
63
63
63
65
890x342x673
946x410x810
946x410x810
946x410x810
952x415x1333
995x398x740
1090x500x865
1090x500x885
1090x500x885
1095x495x1480
43.9/46.9
52.8/57.3
66.9/71.5
80.5/85
103.7/118.3
3500
3800
4000
4000
7500
60
62
63
63
63.5
67
70
70
70
73
Refrigerante
Tubazione
frigorifera
R32
675
1.50
1.013
Ø9.52 (3/8")
Ø15.9 (5/8")
50
3
25
5
24
OD Ø25
4 fili+terra
Telecomando
+16~+30
-15~+50
-15~+24
R32
675
2.00
1.350
Ø9.52 (3/8")
Ø15.9 (5/8")
50
3
25
5
24
OD Ø25
4 fili+terra
Telecomando
+16~+30
-15~+50
-15~+24
R32
675
2.40
1.620
Ø9.52 (3/8")
Ø15.9 (5/8")
75
3
30
5
24
OD Ø25
4 fili+terra
Telecomando
+16~+30
-15~+50
-15~+24
R32
675
2.40
1.620
Ø9.52 (3/8")
Ø15.9 (5/8")
75
3
30
5
24
OD Ø25
4 fili+terra
Telecomando
+16~+30
-15~+50
-15~+24
R32
675
2.80
1.890
Ø9.52 (3/8")
Ø15.9 (5/8")
75
3
30
5
24
OD Ø25
4 fili+terra
Telecomando
+16~+30
-15~+50
-15~+24
Diametro tubazioni drenaggio acqua
Cavo di comunicazione fra U.I. e U.E.
Tipo di controllo
Unità interna
Temperature di
Unità esterna (Raffred.)
esercizio
Unità esterna (Riscald.)
Valore di EER e COP misurato secondo la norma armonizzata EN14511. Valore di SEER misurato secondo la norma armonizzata EN14825. Regolamento UE N.206/2012. La perdita di refrigerante contribuisce al cambiamento climatico. In caso di rilascio nell’atmosfera. i
refrigeranti con un potenziale di riscaldamento globale (GWP) più basso contribuiscono in misura minore al riscaldamento globale rispetto a quelli con un GWP pi
ù elevato. Questo apparecchio contiene un fluido refrigerante con un GWP di 675. Se 1 Kg di questo fluido refrigerante
fosse rilasciato nell’atmosfera. quindi. l’impatto sul riscaldamento globale sarebbe 675 volte più elevato rispetto a 1 Kg di CO2. per un periodo di 100 anni. In nessun caso l’utente deve cercare di intervenire sul circuito refrigerante o di disassemblare il prodotto. In caso di necessità
occorre sempre rivolgersi a personale qualificato. Consumo di energia (kWh/anno) in base ai risultati di prove standard. Il consumo effettivo dipende dalle modalit
à di utilizzo dell’apparecchio e dal luogo in cui è installato. EER/COP dichiarati solo al fine delle detrazioni fiscali in
vigore all’atto della realizzazione di questa pubblicazione. Condizioni di test: PdesignC = Carico termico teorico in raffreddamento con temperatura esterna di 35°C (BS)/24°C (BU) e temperatura interna di 27°C (BS)/19°C (BU). PdesignH = Carico termico teorico in riscaldamento
con temperatura esterna di -10°C (BS)/-11°C (BU) e temperatura interna di 20°C (BS)/15°C (BU). Raffreddamento = Temperatura aria interna di 27°C (BS)/19°C (BU) e temperatura aria esterna di 35°C (BS)/24°C (BU). Riscaldamento = Temperatura aria interna di 20°C (BS)/15°C
(BU) e temperatura aria esterna di 7°C (BS)/6°C (BU). I livelli sonori sono misurati in una camera semi-anecoica. in una posizione di 1 m davanti all’unità e 1.3 m dal pavimento.
Le immagini dei prodotti sono da considerarsi come puramente indicative. Per maggiori informazioni far riferimento alle schede tecniche. Per la politica di continuo
miglioramento dei prodotti perseguita da IDEMA®. le caratteristiche sopra riportate sono soggette a modifiche senza alcun obbligo di preavviso.