LINEA COMMERCIALE

SISTEMI TWIN

COMMERCIALI

LE COMBINAZIONI DEI SISTEMI TWIN COMMERCIALI PREVEDONO: UNA UNITÀ ESTERNA. DUE UNITÀ INTERNE

DELLA STESSA TIPOLOGIA E DELLA STESSA CAPACITÀ. UN GIUNTO A Y PER LINEA GAS E LINEA LIQUIDO E UN

COMANDO REMOTO A PARETE.

QUANDO UN SISTEMA FUNZIONA IN MODALITÀ

TWIN. IL COMANDO REMOTO A PARETE AGISCE SOLO

SULL’UNITÀ MAIN (UNITÀ INTERNA PRINCIPALE).

L’UNITÀ SLAVE (UNITÀ INTERNA SECONDARIA)

FUNZIONA CON LE STESSE MODALITÀ DELL’UNITÀ

INTERNA PRINCIPALE. LE DUE UNITÀ INTERNE

FUNZIONANO CON LA STESSA MODALITÀ. CON LA

STESSA TEMPERATURA E LA STESSA VELOCITÀ DI

VENTILAZIONE. LA CAPACITÀ DI RESA DELL’UNITÀ

ESTERNA È LA SOMMA DELLA CAPACITÀ DELLE

DUE UNITÀ INTERNE INSTALLATE. QUANDO L’UNITÀ

MAIN (UNITÀ INTERNA PRINCIPALE) SMETTE DI

FUNZIONARE. L’UNITÀ SLAVE (UNITÀ INTERNA

SECONDARIA) SI FERMERÀ.

COMBINAZIONI TWIN

FOR MAIN-SLAVE SETTING

SW5

ON

12

ON

12

ON

12

ON

12

MODE

MAIN

NO SLAVE

MAIN

MAIN

SLAVE

FACTORY

SETTING

Configurare le unità interne

Il microinterruttore SW5 serve per impostare l'unità MAIN o SLAVE quando l'unità interna è in

modalità Twin. (1) Unità interna MAIN: posizione alternata di 1 e 2 (uno in ON e l’altro in OFF); (2)

Unità interna SLAVE: 1 e 2 entrambi in ON.

COMBINAZIONE

GIUNTO FRIGORIFERO

UNITÀ ESTERNA

CODICE PRODOTTO

UNITÀ INTERNA E PANNELLO

COMANDO

REMOTO A PARETE

2x

1x IOZ-160T-R32

2x ICZ-88-R32

1x FQZHN01D

1x KJR-120C/TF-E

SISTEMA TWIN

(2x 8.8 kW) TRIFASE

2x

SISTEMA TWIN

(2 x 7.0 kW) TRIFASE

SISTEMA TWIN

(2 x 7.0 kW) TRIFASE

SISTEMA TWIN

(2 x 7.0 kW) TRIFASE

2x IUZ-70-R32

1x IOZ-140T-R32

1x IOZ-140T-R32

1x IOZ-140T-R32

2x ICZ-70-R32

1x FQZHN01D

1x FQZHN01D

1x FQZHN01D

1x KJR-120C/TF-E

1x KJR-120C/TF-E

1x KJR-120C1/BTF-E(AU)

COMBINAZIONE

GIUNTO FRIGORIFERO

UNITÀ ESTERNA

CODICE PRODOTTO

UNITÀ INTERNA

COMANDO

REMOTO A PARETE

2x

1x IOZ-160T-R32

2x IUZ-88-R32

1x FQZHN01D

1x KJR-120C/TF-E

SISTEMA TWIN

(2x 8.8 kW) TRIFASE

2x

COMBINAZIONE

CODICE PRODOTTO

GIUNTO FRIGORIFERO

COMANDO

REMOTO A PARETE

UNITÀ ESTERNA

UNITÀ INTERNA

2x

1x IOZ-160T-R32

2x ITZ-88-R32

1x FQZHN01D

1x KJR-120C1/BTF-E(AU)

SISTEMA TWIN

(2x 8.8 kW) TRIFASE

2x

2x ITZ-70-R32

54

Le immagini dei prodotti sono da considerarsi come puramente indicative. Per maggiori informazioni far riferimento alle schede tecniche. Per la politica di continuo

miglioramento dei prodotti perseguita da IDEMA®. le caratteristiche sopra riportate sono soggette a modifiche senza alcun obbligo di preavviso.