Climatizzazione Gli Invisibili - Air conditioning The Invisibles

IDRA ECO MULTISPLIT

CLIMATIZZATORE INVISIBILE ACQUA-ARIA

INVISIBLE WATER COOLED CONDENSING UNIT

41

dB

ULTRA

SILENT

FULL DC

INVERTER

IDRA3-E24C

IDRA3-E24H

230-50-1

25

2,5

7000/23884

2300/7800

1440

650/2100

4,85

A+++

7000/23884

2300/7800

1540

650/2100

4,55

A++

42

52

EEV

2.0

I

L

I

S

E

L

B

I

S

B

I

S

IDRA ECO Multisplit DC inverter

SOLO CONDIZIONAMENTO - Only Cooling

POMPA DI CALORE - Heat Pump

Alimentazione - Power Supply

Protezione da sovracorrente - Max Overcurrent Protection

Sezione cavi alimentazione - Power cable cross-sectional area

Cod.

IDRA2-E18C

Cod.

IDRA2-E18H

V-Hz-Ph

230-50-1

A

25

mm

2

2,5

W/BTU

5200/17742

W

2100/5900

W

1040

W

360/1790

W/W

4,98

-

A+++

W/BTU

5200/17742

W

2550/5950

W

1100

W

350/1820

W/W

4,73

-

A++

dB(A)

42

dB(A)

52

-

EEV

IDRA4-E28C

IDRA4-E28H

230-50-1

25

4,0

8200/28000

2300/9100

1700

650/2900

4,81

A+++

8200/28000

2300/8900

1810

650/2700

4,53

A++

42

52

EEV

IDRA4-E36C

IDRA4-E36H

230-50-1

25

4,0

10500/35826

3100/12100

1970

750/4100

5,32

A+++

10500/35826

3100/12100

2070

750/3900

5,07

A++

44

54

EEV

WI-FI

CLASSE

ENERGETICA

A+++

R32

CONTO

TERMICO 2.0

REFRIGERANTE

DETRAZIONE

R32

FISCALE

I

V

I

V

N

I

N

I

E

L

G

H

T

Raffreddamento

Cooling

Potenza

Capacity

Nominale - Nominal

Min/Max

Assorbimento elettrico

Nominale - Nominal

Max power absorbtion

Min/Max

EER

Classe energetica - Energy class

Riscaldamento

Heating

Potenza

Capacity

Nominale - Nominal

Min/Max

Assorbimento elettrico

Nominale - Nominal

Max power absorbtion

Min/Max

COP

Classe energetica - Energy class

Pressione sonora - Sound level

Potenza sonora - Sound power

Metodo di regolazione - Throttling method

Dimensioni - Dimensions (LxPxH)

Peso - Weight

Compressore - Compressor

mm

500 x 300 x 530

500 x 300 x 670

500 x 300 x 750

500 x 300 x 750

Refrigerante

Refrigerant

Tubazioni frigorifere

Refrigeration pipes

Tipo - Type

Precarica - Precharge

Carica agg. - Add. Charge

Dimensioni - Dimensions

Max distanza con precarica

Max distance with pre-charge

Max distanza ammissibile “tra UI e UE”/”TOT”

Max allowable distance “between UI and

UE”/”TOT”

Max dislivello ammissibile tra UI e UE

Max elevation difference between IU and OU

Kg

35

-

Panasonic

-

R32

Kg

1,10

gr/m

22

Inch

1/4’’ - 3/8’’ | x2

38

Panasonic

R32

1,30

22

1/4’’ - 3/8’’ | x3

40

Panasonic

R32

1,50

22

1/4’’ - 3/8’’ | x4

42

Mitsubishi

R32

1,90

22

1/4’’ - 3/8’’ | x2

1/4’’ - 1/2’’ | x2

m

10

10

20

20

m

10 / 20

10 / 30

10 / 40

10 / 40

m

5

5

5

5

Attacchi acqua - Water connections

Pressione ottimale acqua in ingresso - Optimal inlet water pressure

Inch

1/2”

bar

1,5 - 2,0

m

3

/h

0,07 / 0,28

m

3

/h

0,09 / 0,95

°C

+16~+31

°C

+12 / +25

1/2”

1,5 - 2,0

0,07 / 0,42

0,09 / 1,37

+16~+31

+12 / +25

1/2”

1,5 - 2,0

0,07 / 0,47

0,09 / 1,58

+16~+31

+12 / +25

1/2”

1,5 - 2,0

0,12 / 0,72

0,15 / 1,69

+16~+31

+12 / +25

Utilizzo d’acqua - Use

of water

Capacit

à - Capacity

15% / 100%

Temperatura impostabile

Set temperature range

Limiti di funzionamento

Operating limits

Raffreddamento - Cooling

Riscaldamento - Heating

Unit

à Interna - Indoor Unit

Acqua ingresso (raffr/risc) - Inlet Water (heat/cool)

N.B.: la normativa non prevede SEER e SCOP per le unità acqua-aria | The regulations do not require SEER and SCOP for water-to-air units.

Condizioni di prova IDRA Raffreddamento: acqua ingresso/uscita 15/30°C

Riscaldamento: acqua ingresso/uscita 10/7°C.

Testing conditions for IDRA Cooling: water inlet/outlet 15/30°C

Heating: water inlet/outlet 10/7°C.

Condizioni di prova unità interna: Raffreddamento: unit

à interna 27°C B.S.

Testing conditions for indoor unit: Cooling: indoor unit at 27°C D.B.

Riscaldamento: unità interna 20°C B.S.

Heating: indoor unit at 20°C D.B.

In riferimento al Decreto Ministeriale 16 febbraio 2016, allegato I e successive modi

fiche, le pompe di calore acqua-aria, risultano detraibili se il COP è superiore o pari al

valore di 4,7. Nel caso di pompe di calore dotate di variatore di velocit

à (inverter o altre tipologie), i valori pertinenti sono ridotti del 5%. Per cui i modelli IDRA ECO, che

sono dotati di tecnologia inverter, rientrano nei criteri di ammissibilità delle detrazioni, quindi sono tutte detraibili avendo COP uguale o superiore a 4,47 (4,7-5%=4,47).

27