Reference Standards
•
Basin Authority guidelines
•
Municipal/Regional Building Regulations
•
Regional Decrees
COLLECTION GRID
inspection cap
COLLECTION GRID
inspection cap
VENT
VENT
inspection cap
BALANCING TANK
BALANCING TANK
BALANCING TANK
WHITE WATER SEWER
inspection cap
SUBMERSIBLE ELECTRIC PUMP
OVERFLOW PIPING
WHITE WATER SEWER
Laminated tanks consist of corrugated containers for underground use of the modular type with high-density recyclable polyethylene
(LLDPE) 100% with rotational moulding technology; they are supplied with inlet and outlet pipes in PVC that guarantee perfect tightness.
On request, the tanks can be equipped with electric pumps and electric panel for the management of the same.
O
V
E
R
A
L
L
H
E
I
G
H
T
,
H
T
O
T
L
E
N
G
T
H
D
I
A
M
E
T
E
R
Ø
M
A
X
I
M
U
M
P
I
P
E
C
O
U
P
L
I
N
G
I
N
/
O
U
T
T
O
T
A
L
V
O
L
U
M
E
MODEL
LAM 40000 M
LAM 80000 M
LAM 120000 M
LAM 160000 M
LAM 200000 M
LAM 240000 M
cm
m
cm
mm
litre
216
13,46
210
400
40.000
216
26,42
210
400
80.000
216
39,38
210
400
120.000
216
52,34
210
400
160.000
216
65,30
210
400
200.000
216
78,26
210
400
240.000
Use of lamination
The waterproofing of the territory, following the
construction of new settlements or industrial businesses,
has highlighted several issues related to the disposal of
rainwater from these areas. In particular, the inadequacy
of existing drainage systems and stream receptors can
have serious hydraulic-quantitative consequences.
Urbanization essentially produces two types of alterations:
1.
it produces a change in the water balance of surface
water due to less infiltration of rainwater into the
ground;
2. during rainfalls, increased hydraulic flow is delivered
to receptors due to increased waterproofing and the
increased speed of surface runoff, worsening the
problems associated with the control of flooding.
These consequences can be controlled by inserting
laminated artefacts into the drainage networks with the
function of provisionally accumulating water volumes
resulting from meteorological events, to send them
subsequently to the network downstream or the final
receptor with reduced flow that is compatible with them.
N.B. For volumes other than those indicated in the table and all
project quotes, contact the Technical Office aquapura@elbi.it
72