Vent Valve
TECHNICAL DATA
Max. working pressure
Working temperature
Thread standard
Media
Material valve body
Material external cover
Material sealing
6 Bar
0-95 oC
G - male thread
Water - Glycol mixture max. 50%
Ethanol mixture max. 30%
Stainless Steel EN 10088 1.4301
PPE + PS Composite
EPDM
LK 770 AeroSafe
• Low pressure drop
• Lead-free
• Side discharge prevents ice formation
• If cleaning is required, the inner part can be easily
dismantled using the quick-release connection
• Compact design
• High flow capacity
LK 770 AeroSafe is used to continuously remove gases / air from
hydraulic circuits.
With an integrated stainless-steel mesh and large area of the
chamber, the air / gas can be efficiently collected and automat-
ically released. The venting outlet is located on the side of the
top, which minimizes the risk of ice formation and blockage
when installed in places where freezing temperatures can occur.
However, the product should always be insulated if there is a
risk of freezing temperatures.
If cleaning is required, the inner part can be easily dismantled
using the quick-release connection.
If LK 770 AeroSafe is installed in connection with, for example,
an air/water heat pump that uses flammable refrigerant gases
(such as R290), it is important that LK 770 is installed outdoors
or in well-ventilated areas where there is no risk for ignition (in
case of leakage between the heat exchanger and the circuit with
refrigerant gases).
In addition to the top cover and float mechanism, the LK 770
is made of stainless steel to maintain a high quality and avoid
hazardous substances such as lead.
27