Linea On/Off
Applicazioni tipiche
– Apparecchidipost
trattamento d’aria
– Accumulobollitore
– Regolazioneperzona
PN 16
Scheda tecnica
Servocomandi
SFA..
SUA21/3 *
STA..
SSA31.04 1)
Tensione di
funzionam.
AC230V
AC24V
AC/DC 24 V
1...110 °C
N4842
VVI46.15
VVI46.20
VVI46.25
VXI46.154)
VXI46.204)
VXI46.254)
VXI46.25T5)
Foglio tecnico
N4863
N4830
N4884
N4860
Segnale di
posizione
2-punti
2-punti
2-punti/SPST 2)
3-punti/SPDT 2)
2-punti
0...10V
2703)
2-punti/PDM
270
2.5 mm
4.5 mm
2.5 mm
200N
150N
100N
160N
*
Tempo di
pos. [s]
10
210
10
Ritorno a
molla [s]
43
10
30-50
SFA21/18
–
–
–
–
–
–
STA2
3
–
–
–
SUA21/
3
–
–
–
–
–
–
SSA31.04
30-50
SFA71/18
–
–
–
–
–
–
STA63
–
–
–
–
STA7
3
–
DN
15
20
25
15
20
25
25
Rp
[pollici]
Rp1⁄2
Rp3⁄4
Rp1
Rp1⁄2
Rp3⁄4
Rp1
Rp1
k
vs
[m3/h]
2
3.5
5
∆p
s
[kPa]
300
300
300
∆p
max
[kPa]
300
300
300
300
300
300
200
∆p
s
[kPa]
300
300
250
–
–
–
–
LED
∆p
max
∆p
s
[kPa]
[kPa]
300
200
300
200
250
200
300
–
300
–
300
–
200
–
∆p
max
[kPa]
200
200
200
200
200
200
200
2
–
3.5
–
5
–
5
–
Attuatore termico e cavo di collegamento per la gamma combinabile, STx..3..
Colore
Dotato
Segnale di pos.
1m
2m
3m
5m
ASY23L50
7m
ASY23L70
10m
ASY23L100
15m
ASY23L150
Modulo di funzione
0...10 V DC
Bianco
Contatti
ausiliari per STA
2-punti
(On/Off)
[STA.., NC]
–
ASA23U10
Contatti
ausiliari per STP
2-punti
(On/Off)
–
[STP.., NO]
ASP23U10
Nero
–
–
2-punti
(On/Off)
[STA.., NC]
[STP.., NO]
ASY23L20
DC 0...10 V
[STA.., NC]
–
ASY6AL20
ASY6AL20HF
n
n
DC 0...10 V
–
[STP.., NO]
ASY6PL20
ASY6PL20HF
2-punti
2-punti
(On/Off)
(On/Off)
[STA.., NC]
[STA.., NC]
[STP.., NO]
[STP.., NO]
ASY23L20LD
n
n
n
n
n
ASY23L30B
ASY23L50B
2m
ASY23L20HF
5m
ASY23L50HF
10m
ASY23L100HF
H
C
a
v
o
p
r
i
v
o
C
a
v
o
P
V
C
s
t
a
n
d
a
r
d
d
i
a
l
o
g
e
n
i
Servocomandi
STA73/00
STA23/00
STP73/00
STP23/00
STA73PR/00 6)
STP73PR/00 6)
STA73MP/00 7)
STA23MP/00 7)
STA73B/00
STA23B/00
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
*) non disponibili in Italia
1) Non adatto a valvole con corpo riscaldante
2) SPST = single-pole single-throw, SPDT = single-pole double-throw
3) In control mode (warm-up time) min. running time approx. 30 s/mm
4) 70% k
vs
in bypass‚ leakage rate in bypass 2...5% of k
vs
value
5) 100% kvs in bypass‚ leakage rate in bypass 0.05% of kvs value. For noiseless operation, the value of 100 kPa should not be exceeded.
6) Servocomandi adatti per il funzionamento in parallelo. Modulazione della durata degli impulsi (PDM) in rapporto ai regolatori per l‘ambiente
Siemens della serie Desigo e dei termostati per l‘ambiente.
7) Multipack con 50 attuatori (OEM) NC: normally closed/chiuso senza corrente, NO: normally open/aperto senza corrente
VI
Siemens S.p.A.
Soggetto a modifiche
2018
Building Technologies Division