Valvole magnetiche
Applicazioni tipiche
TIpo
Segnale
0...10 V,
0...10 V,
0...10 V,
0...10 V,
0...10 V,
0...10 V,
0...10 V,
Suffisso
2...10 V, 4...20 mA
P1)
4...20 mA
P1)
2...10 V, 0...20 mA, 4...20 mA
–
– Teleriscaldamento
– Circuiti di caldaia
– Circuiti frigoriferi
– Acqua calda sanitaria
– Macchine HVAC
MXF461..
M3P..FY..
MVF461H..
MXG461..
MXG461B..
MXG461S..
MXG462S..
Tensione di funzionamento
AC/DC 24V
AC 24 V
AC/DC 24V
AC/DC 24V
AC/DC 24V
AC/DC 24V
AC/DC 24V
DN
k
vs
[m3/h]
15
0.6/1.5/3
20
5
25
8
32
12
40
20
50
30
65
50
80
80
100
130
P 1)
2...10 V, 0...20 mA, 4...20 mA
–
2...10 V, 4...20 mA
–
2...10 V, 0...20 mA, 4...20 mA
–
2...10 V, 4...20 mA
– Air handling
PN 16
Foglio tecnico
PN 16
Foglio tecnico
PN 16
Foglio tecnico
PN 16
Foglio tecnico
PN 16
Foglio tecnico
units
1...130 °C
N4455
MXF461.15-.. 2)
MXF461.20-5.0
MXF461.25-8.0
MXF461.32-12
MXF461.40-20
MXF461.50-30
MXF461.65-50
1...120 °C
N4454
M3P80FY
M3P100FY
1...180 °C
N4361
MVF461H15-.. 2)
MVF461H20-5
MVF461H25-8
MVF461H32-12
MVF461H40-20
MVF461H50-30
1...130 °C
N4455
MXG461.15-.. 2)
MXG461.20-5.0
MXG461.25-8.0
MXG461.32-12
MXG461.40-20
MXG461.50-30
-20...130 °C
N4461
MXG461B15-.. 2)
MXG461B20-5
MXG461B25-8
MXG461B32-12
MXG461B40-20
MXG461B50-30
1...130 °C
N4465
MXG461S15-1.5
MXG461S20-5.0
MXG461S25-8.0
MXG461S32-12
–
∆p
s
∆p
max
[kPa] [kPa]
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
200
200
∆p
s
∆p
max
Note
Impiego come valvola a 2 vie o di
miscela, non in deviazione. Curva
caratteristica della valvola equiper-
centuale o lineare
DN
k
vs
[m3/h]
[kPa] [kPa]
15
0.6/1.5/3
20
5
25
8
32
12
40
20
50
30
DN
G
k
vs
[pollici] [m3/h]
15 G1B
0.6/1.5/3
20 G 11⁄4B
5
25 G 11⁄2B
8
32 G2B
12
40 G 21⁄4B
20
50 G 23⁄4B
30
DN
G
k
vs
[pollici] [m3/h]
15 G1B
0.6/1.5/3
20 G 11⁄4B
5
25 G 11⁄2B
8
32 G2B
12
40 G 21⁄4B
20
50 G 23⁄4B
30
DN
G
k
vs
[pollici] [m3/h]
15 G1B
1.5
20 G 11⁄4B
5
25 G 11⁄2B
8
32 G2B
12
50 G 23⁄4B
30
1000 1000
1000 1000
1000 1000
1000 1000
1000 1000
1000 1000
∆p
s
∆p
max
[kPa] [kPa]
300
300
300
300
300
300
300
300
300
300
300
300
∆p
s
∆p
max
[kPa] [kPa]
1000 1000
800
800
700
700
600
600
600
600
600
600
∆p
s
∆p
max
[kPa] [kPa]
300
300
300
300
300
300
300
300
600
600
-20...130 °C
N4466
–
–
–
–
MXG462S50-30
Note
Impiego come valvola a 2 vie o di
miscela, non in deviazione. Curva
caratteristica della valvola equiper-
centuale o lineare
1) P = fluido contenente olii minerali
2) .. = insert k
vs
value
3) Parts that are in contact with medium in stainless steel
Siemens S.p.A.
Building Technologies Division
Soggetto a modifiche
XV
2018