INDICE GENERALE

UNITÀ INTERNE IDRCOHNILICLHERE

Caratteristiche tecniche

Unità Comfort con ventilatore

EC

P-FC10

2V / 5V / 10V

1)

P-FC20

2V / 5V / 10V

1)

P-FC30

2V / 6V / 10V

1)

P-FC40

2V / 5V / 10V

1)

P-FC50

2V / 7V / 10V

1)

P-FC60

2V / 7V / 10V

1)

P-FC70

4V / 8V / 10V

1)

P-FC80

3V /4,1V / 6,4V

1)

A 2 tubi

A 4 tubi

Livelli sonori

Potenza sonora

Pressione sonora

6)

NR

6)

Ventilazione

Numero di ventilatori

A

A

dB(A)

34/47/60

dB(A)

34/47/60

dB(A)

25/38/51

dB(A)

25/38/51

20/33/46

20/33/46

34/47/60

34/47/60

25/38/51

25/38/51

20/33/46

20/33/46

31/50/59

31/50/59

22/41/50

22/41/50

17/36/45

17/36/45

29/44/52

29/44/56

20/35/43

20/35/43

15/30/38

15/30/38

30/51/57

30/51/57

21/42/48

21/42/48

16/37/43

16/37/43

32/54/58

32/54/58

23/45/49

23/45/49

18/40/44

18/40/44

40/54/59

40/54/59

31/45/50

31/45/50

26/40/45

26/40/45

51/56/64

51/56/64

42/47/55

42/47/55

37/42/50

37/42/50

3

685/927/1398

660/884/1548

Capacità di raffrescamento

totale

2)

kW

0,59 / 1,16 / 1,96

0,61 / 1,31 / 2,12

0,67 / 1,41 / 1,83

1,34 / 2,93 / 4,19

1,34 / 3,57 / 4,98

1,98 / 4,45 / 5,24

2,55 / 5,56 / 6,55

4,59 / 6,13 / 8,36

Capacità sensibile

2)

kW

0,48 / 1,00 / 1,76

0,47 / 1,06 / 1,72

0,47 / 1,04 / 1,34

0,95 / 2,10 / 3,00

1,05 / 2,70 / 3,70

1,35 / 3,51 / 4,02

1,91 / 4,10 / 4,96

3,32 / 4,51 / 6,28

Portata acqua

2)

l/h

102/200/338

105/226/365

141/336/505

231/505/722

231/615/858

341/767/903

439/958/1128

791 / 1056 / 1440

Perdita di carico acqua

2) 3)

kPa

7,5 / 25,7 / 69,5

1,4/4,3/9,3

5,9 / 21,8 / 42,9

6,4 / 24,3 / 46,3

4,9 / 28,7 / 53,9

7,8 / 35,8 / 49,0

2,7 / 12,6 / 17,5

11,8 / 19,5 / 34,2

Capacità di riscaldamento

4)

kW

0,67 / 1,30 / 2,31

0,68 / 1,53 / 2,52

0,80 / 1,72 / 2,66

1,11 / 2,48 / 4,46

1,38 / 3,89 / 5,19

1,95 / 4,93 / 5,82

3,05 / 5,81 / 7,17

4,63 / 6,39 / 9,28

Portata acqua

4)

l/h

115/224/398

117/264/434

138/296/458

191/427/768

238/670/894

336/849/1002

525 / 1001 / 1235

798 / 1101 / 1598

Perdita di carico acqua

3) 4)

kPa

6,5 / 20,6 / 59,1

1,7/5,5/12,4

4,1 / 14,2 / 30,4

4,8 / 18,1 / 51,9

3,8 / 25,7 / 44,6

12,2 / 70,7 / 97,5

3,9 / 13,8 / 20,9

11,9 / 21,0 / 41,5

Capacità di raffrescamento

totale

2)

kW

0,51 / 1,02 / 1,80

0,57 / 1,20 / 2,18

0,75 / 1,84 / 2,93

1,03 / 2,20 / 3,52

1,17 / 3,45 / 4,39

1,69 / 3,90 / 4,69

2,44 / 4,88 / 6,06

4,44 / 5,86 / 9,07

Capacità sensibile

2)

kW

0,41 / 0,87 / 1,60

0,43 / 0,96 / 1,76

0,55 / 1,44 / 2,28

0,73 / 1,57 / 2,58

0,92 / 2,61 / 3,28

1,12 / 3,05 / 3,63

1,83 / 3,61 / 4,53

3,20 / 4,31 / 6,84

Portata acqua

2)

l/h

87,8/176/310

98,2/207/376

129/317/505

177/379/606

202/594/756

291/672/808

420/841/1044

765 / 1009 / 1562

Perdita di carico acqua

2) 3)

kPa

5,2 / 18,3 / 53,4

1,3/3,8/9,7

4,0 / 13,7 / 28,0

9,3 / 27,8 / 58,9

2,3 / 16,2 / 25,6

4,6 / 22,0 / 31,4

3,2 / 12,3 / 18,8

18,8 / 30,6 / 67,2

Capacità di riscaldamento

5)

kW

0,61 / 1,13 / 1,87

0,79 / 1,33 / 2,09

1,41 / 2,01 / 2,77

1,57 / 2,49 / 3,62

2,18 / 3,34 / 4,10

1,81 / 4,05 / 4,81

3,45 / 4,67 / 5,53

5,74 / 7,99 / 12,90

Portata acqua

5)

l/h

52,5 / 97,3 / 161

68/115/180

121/173/239

135/214/312

188/288/353

156/349/414

297/402/476

494/688/1111

Perdita di carico acqua

3) 5)

kPa

1,1/2,4/4,8

<1/2,0/4,8

7,9 / 12,3 / 18,6

10,9 / 22,2 / 41,1

6,5 / 13,6 / 19,6

16,1 / 45,3 / 57,5

32,2 / 53,9 / 72,4

19,2 / 34,5 / 83,1

A

A

A

A

A

A

2 tubi

4 tubi

2 tubi

4 tubi

2 tubi

4 tubi

2 tubi

4 tubi

Portata d'aria

Filtro

Dati elettrici

Alimentazione

Consumo

1

1

1

2

2

2

2

m3/h

108/228/417

98/234/413

119/257/345 170/412/678 203/577/816 245/737/912 350/850/1050

m3/h

91/199/379

84/200/380

123/297/540 148/298/524 185/587/755 205/668/845

329/798/989

G2

G2

G2

G2

G2

G2

G2

G2

Tensione

Fase

Frequenza

A 2 tubi

A 4 tubi

V

Hz

230

Monofase

50 / 60

230

Monofase

50 / 60

230

Monofase

50 / 60

230

Monofase

50 / 60

230

Monofase

50 / 60

230

Monofase

50 / 60

230

Monofase

50 / 60

230

Monofase

50 / 60

23/42/108

22/41/116

1250 / 2500

Filettatura gas

femmina

3⁄4

1⁄2

1506 x 225 x 575

1316x220x530

W

7/12/41

7/13/41

6/16/42

2/13/43

4/23/46

4/30/54

11/44/77

W

7/12/39

7/13/40

6/14/40

2/11/39

4/23/44

4/28/52

11/43/75

Resistenza elettrica

Connessioni acqua

Tipo di connessione

W

500

Filettatura gas

femmina

500

Filettatura gas

femmina

500 / 1000

Filettatura gas

femmina

1250

Filettatura gas

femmina

1250 / 2500

Filettatura gas

femmina

1250 / 2500

Filettatura gas

femmina

1250 / 2500

Filettatura gas

femmina

A 2 o 4 tubi

A 4 tubi

Dimensioni

Con pannellatura

- senza piedini

Senza pannellatura

Peso

Con pannellatura

Senza

pannellatura

Raffrescamento

Riscaldamento

L x Px A

L x Px A

A 2 tubi

A 4 tubi

A 2 tubi

A 4 tubi

Pollici

1⁄2

1⁄2

1⁄2

1⁄2

1⁄2

1⁄2

3⁄4

Pollici

1⁄2

1⁄2

1⁄2

1⁄2

1⁄2

1⁄2

1⁄2

mm

766x225x477 766x225x477 951x225x477

1136 x 225 x

1321 x 225 x

1506 x 225 x

1319x225x575

477

477

477

mm

570x220x430 570x220x430 753x220x430 938x220x430 1122x220x430 1307x220x430 1121x220x530

k

g

1

9

1

9

2

2

2

7

3

0

3

5

3

5

47

kg

20

20

23

29

32

37

37

49

k

g

1

3

1

3

1

5

2

0

2

2

2

6

2

7

38

k

g

1

4

1

4

1

6

2

2

2

4

2

8

2

9

40

Classe di efficienza energetica

7)

1) Velocità standard del ventilatore impostate in fabbrica (tensione). 2) Secondo lo standard Eurovent. Aria: 27 °C B.S./19 °C B.U., acqua fredda: 7 °C/12 °C. 3) Perdita di carico a portata nominale

corrispondente. 4) Secondo lo standard Eurovent. Aria: 20 °C, acqua calda: 45 °C/40 °C. 5) Secondo lo standard Eurovent. Aria: 20 °C, acqua calda: 65 °C/55 °C. 6) Dati informativi, considerando un'ipotetica

attenuazione acustica dell'ambiente e dell'installazione di 9 dB(A). 7) Secondo Eurovent.

ErP

Unità Comfort con ventilatore EC

A 2 tubi

FCEER

C

C

B

A

A

A

B

B

FCCOP

D

C

C

B

A

B

B

B

A 4 tubi

FCEER

C

C

B

A

B

B

B

A

FCCOP

C

C

B

A

B

B

B

A

VENTILAZIONE

PRESTAZIONI DI

GREEN MOTORE EC

SUPER QUIET

ALTISSIMO LIVELLO

Conforme alla direttiva ErP secondo il REGOLAMENTO DELLA COMMISSIONE (UE) n. 2016/2281.

Le specifiche sono soggette a modifiche senza preavviso. Per informazioni dettagliate su ErP / Etichette energetiche, visitate i nostri siti web www.aircon.panasonic.eu o www.ptc.panasonic.eu.

81