CURVE E DATI DI PRESTAZIONE
–
n= 1450 min-1
50 Hz
US g.p.m.
Imp g.p.m.
feet
70
60
50
40
30
20
10
270 300
0
24
0
22
20
18
16
14
12
10
8
6
4
2
0
0
TIPO
Trifase
Q = Portata
250
250
500
750
1000
1250
VXC4-200/80
VXC4-150/80
VXC4-125/80
VXC4-100/80
P
r
e
v
a
l
e
n
z
a
H
(
m
e
t
r
i
)
4
VXC4-100/80
7.5
10
H
metri
15
14.7
14.5
13.5
12.2
10.6
8.7
6.7
4.5
VXC4-125/80
9.2
12.5
17
16.7
16.5
15.5
14.3
12.7
10.8
8.6
6.3
5
VXC4-150/80
11
15
19
18.8
18.6
17.7
16.4
15
13
10.7
8.2
7
5.5
VXC4-200/80
15
20
22.5
22.1
22
21
20
18.5
16.7
14.7
12.3
11
9.8
7
ASSORBIMENTI
TIPO
Trifase
VXC4-100/80
VXC4-125/80
VXC4-150/80
VXC4-200/80
TENSIONE
500
50
1000
1500
2000
100
Q
m3/h
0
l/min
0
2500
150
3000
3500
200
4000
180
4500
5000
300
240 255
l/min
m3/h
H = Prevalenza manometrica totale
Tolleranza delle curve di prestazione secondo EN ISO 9906 Grado 3B.
POTENZA(P2)
kW
HP
48
60
90 120
150
210
230 V - t
400 V - s
400 V - t
690 V - s
32.9 A
36.3 A
40.7 A
49.3 A
19.0 A
21.0 A
23.5 A
28.5 A
19.0 A
21.0 A
23.5 A
28.5 A
11.0 A
12.1 A
13.6 A
16.5 A
500
750
1000
Portata Q4
800 1000 1500 2000 2500 3000 3500 4000 4250 4500 5000
250
445