394
www.aermec.com
ANL-021-202-CO_I_CE50_04
INDICI ENERGETICI (REG. 2016/2281 UE)
Taglia
SEER - 12/7 (EN14825: 2018) con ventilatori standard (1)
021
- (2)
4,18
026
- (2)
4,20
031
- (2)
4,17
041
050
- (2)
- (2)
4,10
4,16
070
- (2)
4,34
080
- (2)
4,19
090
- (2)
4,31
102
- (2)
4,11
- (2)
- (2)
- (2)
152
- (2)
4,11
- (2)
- (2)
- (2)
202
- (2)
4,10
- (2)
- (2)
- (2)
SEER
Efficienza stagionale
°
W/W
A,P
W/W
N
W/W
Q
W/W
°
%
-
-
-
-
-
-
-
-
-
-
-
-
- (2)
- (2)
- (2)
- (2)
- (2)
- (2)
- (2)
- (2)
- (2)
- (2)
- (2)
- (2)
SEER - 23/18 (EN14825: 2018) con ventilatori standard (3)
SEER
Efficienza stagionale
°
W/W
A,P
W/W
N
W/W
Q
W/W
4,34
4,35
4,31
4,21
4,55
4,68
4,49
4,61
4,83
4,73
4,69
4,49
4,51
4,48
4,47
4,55
4,64
4,57
4,66
4,49
4,25
4,28
-
-
-
-
-
-
-
-
4,15
4,18
4,23
-
-
-
-
4,18
4,44
4,35
4,49
4,15
4,18
4,23
SEPR - (EN 14825: 2018) Alta temperatura con ventilatori standard (3)
SEPR
°
W/W
5,92
5,92
5,85
5,69
6,36
6,50
6,21
6,43
6,79
6,58
6,49
A,P
W/W
6,56
6,57
6,45
6,21
6,74
6,90
6,55
6,78
6,68
6,18
6,17
N
W/W
-
-
-
-
-
-
-
-
5,91
6,09
6,10
Q
W/W
-
-
-
-
6,03
6,28
6,08
6,30
5,91
6,09
6,10
(1) Calcolo eseguito con portata d’acqua FISSA e temperatura d’uscita VARIABILE.
(2) Non conformi al regolamento 2016/2281 UE per applicazioni di comfort 12°C / 7°C
(3) Calcolo eseguito con portata d’acqua FISSA.
DATI ELETTRICI
Taglia
Alimentazione: °
Dati elettrici
Corrente massima (FLA)
Corrente di spunto (LRA)
Taglia
Alimentazione: M
Dati elettrici
Corrente massima (FLA)
Corrente di spunto (LRA)
DATI TECNICI GENERALI
Compressore
Tipo
tipo
021
026
031
041
050
070
080
14,0
16,0
15,0
18,0
090
102
152
202
17,0
22,0
26,0
32,0
19,0
23,0
28,0
34,0
Regolazione compressore
Numero
Circuiti
Tipo
Refrigerante
tipo
Carica refrigerante (1)
kg
Scambiatore lato utenza
Tipo
tipo
1,2
1,2
1,2
1,3
2,8
R410A
2,8
3,0
3,9
5,9
5,9
5,9
Piastre
A,P
%
164,00
164,80
163,60
161,00
163,40
170,70
164,60
169,40
161,30
161,20
161,10
N
%
-
-
-
-
-
-
-
-
- (2)
- (2)
- (2)
Q
%
-
-
-
-
- (2)
- (2)
- (2)
- (2)
- (2)
- (2)
- (2)
°
%
170,40
170,90
169,20
165,20
179,10
184,30
176,60
181,50
190,30
186,00
184,70
A,P
%
176,70
177,50
176,00
175,60
179,00
182,40
179,80
183,50
176,60
167,00
168,00
N
%
-
-
-
-
-
-
-
-
163,10
164,20
166,00
Q
%
-
-
-
-
164,30
174,50
171,10
176,70
163,10
164,20
166,00
°
A,P
N
Q
°
A,P
N
Q
°
A,P
N,Q
°
A,P
N,Q
A
A
A
A
A
A
A
A
A
A
A
A
A
A
5,0
6,0
6,0
9,0
11,0
6,0
7,0
7,0
10,0
13,0
-
-
-
-
-
-
-
-
24,0
28,0
34,0
24,0
28,0
34,0
76,0
87,0
117,0
77,0
89,0
119,0
78,0
89,0
119,0
78,0
89,0
119,0
102
152
202
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
12,0
28,0
38,0
39,0
44,0
65,0
29,0
39,0
40,0
45,0
67,0
14,0
17,0
18,0
75,0
102,0
96,0
77,0
104,0
98,0
-
-
-
-
-
-
-
-
-
-
-
-
66,0
76,0
103,0
97,0
021
026
031
13,0
16,0
18,0
14,0
17,0
19,0
041
050
070
080
090
-
-
-
-
64,0
68,0
69,0
100,0
62,0
69,0
70,0
101,0
-
-
-
-
ANL021
ANL026
ANL031
ANL041
ANL102 ANL152
ANL202
Numero
n°
1
1
1
1
1
1
1
1
1
1
1
Attacchi idraulici lato utenza
Diametro (in/out)
Ø
Ventilatore
Tipo
tipo
1”1/4
Assiale
Asincrono con taglio di fase
Motore ventilatore
Numero
Portata aria
Dati sonori calcolati in funzionamento a freddo (2)
tipo
22,0
23,0
-
-
-
-
-
-
ANL050
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ANL070 ANL080 ANL090
Scroll
On-Off
n°
1
1
1
1
1
1
1
1
2
2
2
n°
1
1
1
1
1
1
1
1
1
1
1
n°
1
1
1
1
1
1
1
1
2
2
2
m3/h
2500
2500
3500
3500
7200
7200
7300
7200
14000
13500
13500
A
R
I
A
-
A
C
Q
U
A