394

www.aermec.com

ANL-021-202-CO_I_CE50_04

INDICI ENERGETICI (REG. 2016/2281 UE)

Taglia

SEER - 12/7 (EN14825: 2018) con ventilatori standard (1)

021

- (2)

4,18

026

- (2)

4,20

031

- (2)

4,17

041

050

- (2)

- (2)

4,10

4,16

070

- (2)

4,34

080

- (2)

4,19

090

- (2)

4,31

102

- (2)

4,11

- (2)

- (2)

- (2)

152

- (2)

4,11

- (2)

- (2)

- (2)

202

- (2)

4,10

- (2)

- (2)

- (2)

SEER

Efficienza stagionale

°

W/W

A,P

W/W

N

W/W

Q

W/W

°

%

-

-

-

-

-

-

-

-

-

-

-

-

- (2)

- (2)

- (2)

- (2)

- (2)

- (2)

- (2)

- (2)

- (2)

- (2)

- (2)

- (2)

SEER - 23/18 (EN14825: 2018) con ventilatori standard (3)

SEER

Efficienza stagionale

°

W/W

A,P

W/W

N

W/W

Q

W/W

4,34

4,35

4,31

4,21

4,55

4,68

4,49

4,61

4,83

4,73

4,69

4,49

4,51

4,48

4,47

4,55

4,64

4,57

4,66

4,49

4,25

4,28

-

-

-

-

-

-

-

-

4,15

4,18

4,23

-

-

-

-

4,18

4,44

4,35

4,49

4,15

4,18

4,23

SEPR - (EN 14825: 2018) Alta temperatura con ventilatori standard (3)

SEPR

°

W/W

5,92

5,92

5,85

5,69

6,36

6,50

6,21

6,43

6,79

6,58

6,49

A,P

W/W

6,56

6,57

6,45

6,21

6,74

6,90

6,55

6,78

6,68

6,18

6,17

N

W/W

-

-

-

-

-

-

-

-

5,91

6,09

6,10

Q

W/W

-

-

-

-

6,03

6,28

6,08

6,30

5,91

6,09

6,10

(1) Calcolo eseguito con portata d’acqua FISSA e temperatura d’uscita VARIABILE.

(2) Non conformi al regolamento 2016/2281 UE per applicazioni di comfort 12°C / 7°C

(3) Calcolo eseguito con portata d’acqua FISSA.

DATI ELETTRICI

Taglia

Alimentazione: °

Dati elettrici

Corrente massima (FLA)

Corrente di spunto (LRA)

Taglia

Alimentazione: M

Dati elettrici

Corrente massima (FLA)

Corrente di spunto (LRA)

DATI TECNICI GENERALI

Compressore

Tipo

tipo

021

026

031

041

050

070

080

14,0

16,0

15,0

18,0

090

102

152

202

17,0

22,0

26,0

32,0

19,0

23,0

28,0

34,0

Regolazione compressore

Numero

Circuiti

Tipo

Refrigerante

tipo

Carica refrigerante (1)

kg

Scambiatore lato utenza

Tipo

tipo

1,2

1,2

1,2

1,3

2,8

R410A

2,8

3,0

3,9

5,9

5,9

5,9

Piastre

A,P

%

164,00

164,80

163,60

161,00

163,40

170,70

164,60

169,40

161,30

161,20

161,10

N

%

-

-

-

-

-

-

-

-

- (2)

- (2)

- (2)

Q

%

-

-

-

-

- (2)

- (2)

- (2)

- (2)

- (2)

- (2)

- (2)

°

%

170,40

170,90

169,20

165,20

179,10

184,30

176,60

181,50

190,30

186,00

184,70

A,P

%

176,70

177,50

176,00

175,60

179,00

182,40

179,80

183,50

176,60

167,00

168,00

N

%

-

-

-

-

-

-

-

-

163,10

164,20

166,00

Q

%

-

-

-

-

164,30

174,50

171,10

176,70

163,10

164,20

166,00

°

A,P

N

Q

°

A,P

N

Q

°

A,P

N,Q

°

A,P

N,Q

A

A

A

A

A

A

A

A

A

A

A

A

A

A

5,0

6,0

6,0

9,0

11,0

6,0

7,0

7,0

10,0

13,0

-

-

-

-

-

-

-

-

24,0

28,0

34,0

24,0

28,0

34,0

76,0

87,0

117,0

77,0

89,0

119,0

78,0

89,0

119,0

78,0

89,0

119,0

102

152

202

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

12,0

28,0

38,0

39,0

44,0

65,0

29,0

39,0

40,0

45,0

67,0

14,0

17,0

18,0

75,0

102,0

96,0

77,0

104,0

98,0

-

-

-

-

-

-

-

-

-

-

-

-

66,0

76,0

103,0

97,0

021

026

031

13,0

16,0

18,0

14,0

17,0

19,0

041

050

070

080

090

-

-

-

-

64,0

68,0

69,0

100,0

62,0

69,0

70,0

101,0

-

-

-

-

ANL021

ANL026

ANL031

ANL041

ANL102 ANL152

ANL202

Numero

1

1

1

1

1

1

1

1

1

1

1

Attacchi idraulici lato utenza

Diametro (in/out)

Ø

Ventilatore

Tipo

tipo

1”1/4

Assiale

Asincrono con taglio di fase

Motore ventilatore

Numero

Portata aria

Dati sonori calcolati in funzionamento a freddo (2)

tipo

22,0

23,0

-

-

-

-

-

-

ANL050

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

ANL070 ANL080 ANL090

Scroll

On-Off

1

1

1

1

1

1

1

1

2

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

2

m3/h

2500

2500

3500

3500

7200

7200

7300

7200

14000

13500

13500

A

R

I

A

-

A

C

Q

U

A