502
www.aermec.com
NRB-0800-3600-CO_I_CE50_13
Taglia
0800
0900
1000
1100
1200
1400
1600
1805
2006
2206
2406
SEPR - (EN 14825: 2018) (3)
SEPR
°
W/W
5,39
A
W/W
5,64
E
W/W
5,56
L
W/W
5,32
N
W/W
5,69
U
W/W
5,67
5,22
5,29
5,22
5,05
5,55
5,54
0900
180,7
193,4
206,1
218,8
408,1
420,8
433,5
446,2
1000
5,17
5,03
5,58
5,30
5,47
5,25
5,31
5,04
5,67
5,60
5,66
5,54
1000
1100
197,0
226,4
222,5
251,8
222,5
264,5
235,2
277,3
424,4
477,1
449,9
502,5
449,9
515,3
462,6
528,0
1100
1200
5,36
5,51
5,52
5,55
5,52
5,56
5,52
5,56
5,58
5,18
5,05
5,53
5,64
5,62
5,66
5,68
5,59
5,69
1200
1400
1600
262,1
291,1
320,1
281,2
310,2
351,9
293,9
322,9
364,6
306,6
335,6
383,2
512,8
625,3
654,3
531,9
644,4
686,1
544,6
657,1
698,8
557,3
669,8
717,4
1400
1600
Scroll
Asincrono
5,58
5,52
5,51
5,51
5,56
5,57
5,55
5,55
5,54
5,53
5,55
5,55
5,53
5,53
5,52
5,54
5,57
5,63
5,60
5,64
5,55
5,55
5,58
5,72
(1) Calcolo eseguito con portata d’acqua FISSA e temperatura d’uscita VARIABILE.
(2) Non conformi al regolamento 2016/2281 UE per applicazioni di comfort 12°C / 7°C
(3) Calcolo eseguito con portata d’acqua FISSA.
DATI ELETTRICI
Taglia
Dati elettrici
Corrente massima (FLA)
Corrente di spunto (LRA)
DATI TECNICI GENERALI
°
A
A,L
A
E,U
A
N
A
°
A
A,L
A
E,U
A
N
A
0800
0800
164,3
177,1
189,8
202,5
352,9
365,6
378,3
391,1
0900
1805
371,3
396,7
428,0
440,7
705,5
730,9
762,2
774,9
2006
2206
2406
416,0
445,0
480,4
454,2
483,2
530,8
472,8
514,5
543,5
485,5
527,2
556,2
750,3
779,3
814,6
788,4
817,4
865,0
807,0
848,7
877,7
819,7
861,4
890,4
2006
2206
2406
Taglia
Compressore
Tipo
Regolazione
compressore
Numero
Circuiti
Refrigerante
Carica refrigerante
circuito 1 (1)
Carica refrigerante
circuito 2 (1)
Potenziale riscalda-
mento globale
1805
Scambiatore lato utenza
Tipo
°,A,E,L,N,U
tipo
°,A,E,L,N,U
tipo
°,A,E,L,N,U
Tipo
°,A,E,L,N,U
n°
4
4
4
4
4
4
4
5
6
6
6
°,A,E,L,N,
U
n
°
2
2
2
2
2
2
2
2
2
2
2
°,A,E,L,N,U
tipo
°
kg
14,0
14,5
15,0
16,0
A,L
kg
15,0
16,0
20,0
22,0
E,U
kg
20,5
20,0
21,5
26,0
N
kg
25,0
26,5
26,5
29,0
°
kg
14,0
14,5
15,0
16,0
A,L
kg
15,0
16,0
20,0
22,0
E,U
kg
20,5
20,0
21,5
27,0
N
kg
25,0
26,5
26,5
30,0
°,A,E,L,N,U
GWP
R410A
20,5
21,0
21,0
21,0
22,5
23,5
25,0
26,0
30,0
28,0
35,0
42,0
20,5
21,0
21,0
21,0
22,5
25,5
28,0
27,0
32,0
31,0
35,0
42,0
2088kgCO
2
eq
Piastre
26,0
26,0
26,0
31,0
25,0
30,0
31,0
32,5
32,0
36,0
44,5
56,0
38,0
43,0
62,0
42,0
29,0
29,0
29,0
34,0
30,0
34,0
34,0
37,5
37,0
39,0
45,5
56,0
42,0
47,0
62,0
49,0
Numero
°,A,E,L,N,U
n°
1
1
1
1
1
1
1
1
1
1
1
Attacchi idraulici
Attacchi (in/out)
°,A,E,L,N,U
Tipo
Attacchi idraulici senza kit idronico
Diametro (in/out)
°,A,E,L,N,U
Ø
3”
Attacchi idraulici con kit idronico
Diametro (in/out)
°,A,E,L,N,U
Ø
3”
3”
3”
3”
3”
3”
3”
3”
3”
Giunti scanalati
3”
4”
3”
4”
4”
4”
4”
4”
4”
4”
4”
4”
(1) La carica riportata in tabella è un valore stimato e preliminare. Il valore finale della carica di refrigerante
è riportato nella targhetta tecnica dell’unità. Per maggiori informazioni contattare sede.
Nelle versioni senza kit idronico il filtro acqua viene fornito a corredo con
un tronchetto per il collegamento, viene fornito montato nelle versioni
con il kit idronico.
A
R
I
A
-
A
C
Q
U
A