Taglia
5602
71,0 (2)
106,0 (2)
113,0 (2)
106,0 (2)
128,0 (2)
113,0 (2)
-
-
-
-
-
6002
73,0
99,0
98,0
99,0
138,0 (2)
98,0
-
-
-
-
-
1
1
2
2
6402
80,0 (2)
99,0 (2)
97,0 (2)
99,0 (2)
138,0 (2)
97,0
-
-
-
-
-
1
1
2
2
6503
74,0 (2)
81,0 (2)
85,0 (2)
81,0 (2)
92,0 (2)
85,0 (2)
74,0 (2)
81,0 (2)
85,0 (2)
81,0 (2)
92,0 (2)
6703
6903
61,0
85,0 (2)
81,0 (2)
92,0 (2)
89,0 (2)
96,0 (2)
81,0 (2)
92,0 (2)
-
-
89,0 (2)
96,0 (2)
65,0
85,0 (2)
81,0 (2)
92,0 (2)
89,0 (2)
96,0 (2)
81,0 (2)
92,0 (2)
-
-
Fascio tubiero
7203
70,0 (2)
75,0
100,0 (2)
75,0 (2)
8403
99,0 (2)
106,0 (2)
-
106,0 (2)
9603
112,0 (2)
95,0
-
95,0
Carica refrigerante circuito 2 (1)
Carica refrigerante circuito 3 (1)
Scambiatore lato utenza
Tipo
Numero
°
kg
A
kg
E
kg
L
kg
N
kg
U
kg
°
kg
A
kg
E,U
kg
L
kg
N
kg
°,A,E,L,N,U
tipo
-
-
-
100,0 (2)
80,0 (2)
75,0
100,0 (2)
75,0 (2)
-
99,0 (2)
106,0 (2)
-
106,0 (2)
-
112,0 (2)
85,0
-
85,0
°
n°
1
A,L
n°
1
E,U
n°
2
N
n°
2
1
1
1
2
2
2
2
2
2
2
-
-
-
-
-
1
1
1
2
2
2
2
-
-
-
-
-
(1) La carica riportata in tabella è un valore stimato e preliminare. Il valore finale della carica di refrigerante è riportato nella targhetta tecnica dell’unità. Per maggiori informazioni contattare sede.
(2) La carica di gas refrigerante è indicativa, per maggiori informazioni contattare sede.
DATI VENTILATORI
Maggiorati
Taglia
Ventilatori: M
Ventilatore maggiorato
Tipo
Motore ventilatore
Ventilatore
Numero
Con prevalenza
Portata aria
Pressione statica utile
Senza prevalenza
Portata aria
Pressione statica utile
Con prevalenza
Livello di potenza sonora
Senza prevalenza
Livello di potenza sonora
Taglia
Ventilatori: M
Ventilatore maggiorato
Tipo
Motore ventilatore
1402
1602
1802
2002
2202
2352
2502
2652
2802
Assiali
Asincrono
Asincrono con taglio di fase
°,A,E,L,N,U
tipo
°,A,U
tipo
E,L,N
tipo
°
n°
6
6
6
8
8
8
8
8
8
A,L
n°
8
8
8
8
10
10
10
12
12
E,U
n°
8
8
10
10
10
12
12
14
14
N
°
A
E
L
N
U
°
n°
10
10
12
12
12
14
14
16
16
m3/h
96000
m3/h
128000
m3/h
92000
m3/h
92000
m3/h
115000
m3/h
128000
96000
128000
92000
92000
115000
128000
96000
128000
128000
128000
115000
115000
92000
92000
138000
138000
160000
160000
128000
128000
160000
160000
115000
138000
115000
115000
138000
161000
160000
192000
128000
144000
160000
192000
138000
161000
115000
138000
161000
184000
192000
224000
144000
192000
161000
138000
184000
224000
A,E,L,N,U
Pa
°
m3/h
A
m3/h
E
m3/h
L
m3/h
N
m3/h
U
m3/h
50
50
108000
108000
144000
144000
92000
92000
92000
92000
115000
115000
144000
144000
50
108000
144000
115000
92000
138000
180000
50
50
144000
144000
144000
180000
115000
115000
92000
115000
138000
138000
180000
180000
50
50
50
144000
144000
144000
180000
180000
216000
138000
138000
161000
115000
115000
138000
161000
161000
184000
216000
216000
252000
50
144000
216000
161000
138000
184000
252000
Pa
50
50
50
50
50
50
50
-
-
°,A,E,L,N,U
Pa
0
0
0
0
0
0
0
0
0
°
dB(A)
96,8
A
dB(A)
97,3
E
dB(A)
89,3
L
dB(A)
88,9
N
dB(A)
90,0
U
dB(A)
97,0
°
dB(A)
97,5
A
dB(A)
98,2
E
dB(A)
89,3
L
dB(A)
88,9
N
dB(A)
90,0
U
dB(A)
97,9
97,0
97,2
97,6
97,8
98,0
98,2
98,4
97,4
97,8
97,9
98,2
98,3
98,4
98,8
89,4
90,2
90,3
90,4
90,8
91,2
91,8
89,0
89,1
89,2
90,3
90,5
90,6
90,8
90,4
90,9
91,0
91,1
91,4
91,4
92,1
97,4
98,0
98,2
98,4
98,8
98,8
99,0
97,6
97,6
97,9
98,1
98,2
98,4
98,4
98,2
98,6
98,7
99,1
99,2
99,2
99,7
89,4
90,2
90,3
90,4
90,8
91,2
91,8
89,0
89,1
89,2
90,3
90,5
90,6
90,8
90,4
90,9
91,0
91,1
91,4
91,4
92,1
98,2
98,9
99,1
99,2
99,7
99,7
100,0
98,4
98,9
92,0
90,9
92,2
99,1
98,4
99,8
92,0
90,9
92,2
100,1
5202
3002
3202
3402
3602
3902
4202
4502
4802
Assiali
Asincrono
°,A,E,L,N,U
tipo
°,A,U
tipo
E,L,N
tipo
Asincrono con taglio di fase
NSM-1402-9603-CO_I_CE50_14
www.aermec.com
563
A
R
I
A
-
A
C
Q
U
A