592

www.aermec.com

TBA-CO_I_UN50_06

TBA - (U)

Taglia

1300

Prestazioni in raffreddamento 12 °C / 7 °C (1)

(1) Dati EN 14511:2022; Acqua scambiatore lato utenza 12 °C / 7 °C; Aria esterna 35 °C

TBA - (N)

Taglia

1300

Prestazioni in raffreddamento 12 °C / 7 °C (1)

(1) Dati EN 14511:2022; Acqua scambiatore lato utenza 12 °C / 7 °C; Aria esterna 35 °C

INDICI ENERGETICI (REG. 2016/2281 UE)

Taglia

1300

1350

1350

1350

5,23

5,41

206,0%

213,5%

6,65

6,61

1350

249,0

249,0

45,0

45,0

1350

2300

2300

2300

5,48

5,60

216,0%

221,0%

6,11

6,52

2300

319,0

329,0

200,0

210,0

2300

2325

2325

2325

5,25

5,48

206,8%

216,1%

6,32

6,80

2325

404,0

413,0

210,0

305,0

2325

2350

3300

2350

3300

2350

3300

5,54

5,54

5,76

5,80

218,4%

218,4%

227,3%

229,1%

6,41

6,13

6,49

6,62

2350

3300

488,0

483,0

498,0

493,0

305,0

374,0

315,0

384,0

2350

3300

Centrifugo

Inverter

3320

3340

3320

3340

3320

3340

5,51

5,49

5,62

5,71

217,5%

216,5%

221,9%

225,4%

6,26

6,33

6,57

6,50

3320

3340

568,0

727,0

577,0

737,0

470,0

565,0

479,0

575,0

3320

3340

3350

4325

3350

4325

3350

4325

5,57

5,35

5,73

5,62

219,8%

211,0%

226,3%

221,6%

6,28

6,12

6,47

6,40

3350

4325

727,0

797,0

737,0

797,0

565,0

720,0

575,0

720,0

3350

4325

SEER - 12/7 (EN14825: 2018) con ventilatori inverter (1)

SEER

Efficienza stagionale

A,E

W/W

N,U

W/W

A,E

%

N,U

%

5,15

5,35

203,1%

211,0%

SEPR - (EN 14825: 2018) Alta temperatura con ventilatori inverter (2)

SEPR

A,E

W/W

6,31

N,U

W/W

6,47

(1) Calcolo eseguito con portata d’acqua FISSA e temperatura d’uscita VARIABILE.

(2) Calcolo eseguito con portata d’acqua FISSA.

DATI ELETTRICI

Taglia

Dati elettrici

Corrente massima (FLA)

Corrente di spunto (LRA)

DATI TECNICI GENERALI

Taglia

Compressore

Tipo

Regolazione compressore

Numero

Circuiti

Refrigerante

Carica refrigerante (1)

Scambiatore lato utenza

Tipo

Numero

Attacchi idraulici

Attacchi (in/out)

Diametro (in/out)

Ventilatore

Tipo

Motore ventilatore

Numero

Portata aria

A,E

A

N,U

A

A,E

A

N,U

A

A,E,N,U

tipo

A,E,N,U

Tipo

1300

165,0

165,0

36,0

36,0

1300

A,E,N,U

A,E,N,U

A,E,N,U

A,E

N,U

A,E,N,U

A,E,N,U

1

1

2

2

2

3

3

3

3

4

1

1

1

2

1

1

2

1

1

2

tipo

kg

81,0

kg

81,0

tipo

166,0

166,0

152,0

163,0

243,0

254,0

R134a

285,0

264,0

296,0

275,0

Fascio tubiero

306,0

317,0

317,0

328,0

387,0

398,0

398,0

398,0

1

1

1

1

1

1

1

1

1

1

A,E,N,U

Tipo

Giunti scanalati

A,E

Ø

3”

4”

6”

6”

6”

6”

6”

6”

8”

8”

N,U

Ø

6”

6”

6”

6”

6”

6”

6”

6”

8”

8”

A,E,N,U

tipo

Assiali

A,E,N,U

tipo

Inverter

A,E

6

8

10

12

14

16

18

20

20

22

N,U

6

8

12

14

16

18

20

22

22

22

A,E

m3/h

112920

150560

188200

225840

263480

301120

338760

376400

376400

414040

N,U

m3/h

112920

150560

225840

263480

301120

338760

376400

414040

414040

414040

(1) La carica riportata in tabella è un valore stimato e preliminare. Il valore finale della carica di refrigerante è riportato nella targhetta tecnica dell’unità. Per maggiori informazioni contattare sede.

Potenza frigorifera

kW

328,1

443,8

633,5

758,5

876,4

985,0

1088,0

1154,9

1256,9

1342,4

Potenza assorbita

kW

92,3

124,4

178,8

213,2

245,5

275,4

306,8

326,3

358,1

386,6

Corrente assorbita totale a freddo

A

145,7

200,9

281,4

341,6

401,9

437,1

487,3

522,6

582,6

627,6

EER

W/W

3,56

3,57

3,54

3,56

3,57

3,58

3,55

3,54

3,51

3,47

Portata acqua utenza

l/h

56452

76308

108940

130424

150669

169356

187070

198556

216075

230760

Perdita di carico lato utenza

kPa

51

25

49

50

30

53

56

53

36

38

Potenza frigorifera

kW

328,1

443,8

633,5

758,5

876,4

985,0

1088,0

1154,9

1256,9

1342,4

Potenza assorbita

kW

92,3

124,4

178,8

213,2

245,5

275,4

306,8

326,3

358,1

386,6

Corrente assorbita totale a freddo

A

145,7

200,9

281,4

341,6

401,9

437,1

487,3

522,6

582,6

627,6

EER

W/W

3,56

3,57

3,54

3,56

3,57

3,58

3,55

3,54

3,51

3,47

Portata acqua utenza

l/h

56452

76308

108940

130424

150669

169356

187070

198556

216075

230760

Perdita di carico lato utenza

kPa

51

25

49

50

30

53

56

53

36

38

A

R

I

A

-

A

C

Q

U

A