592
www.aermec.com
TBA-CO_I_UN50_06
TBA - (U)
Taglia
1300
Prestazioni in raffreddamento 12 °C / 7 °C (1)
(1) Dati EN 14511:2022; Acqua scambiatore lato utenza 12 °C / 7 °C; Aria esterna 35 °C
TBA - (N)
Taglia
1300
Prestazioni in raffreddamento 12 °C / 7 °C (1)
(1) Dati EN 14511:2022; Acqua scambiatore lato utenza 12 °C / 7 °C; Aria esterna 35 °C
INDICI ENERGETICI (REG. 2016/2281 UE)
Taglia
1300
1350
1350
1350
5,23
5,41
206,0%
213,5%
6,65
6,61
1350
249,0
249,0
45,0
45,0
1350
2300
2300
2300
5,48
5,60
216,0%
221,0%
6,11
6,52
2300
319,0
329,0
200,0
210,0
2300
2325
2325
2325
5,25
5,48
206,8%
216,1%
6,32
6,80
2325
404,0
413,0
210,0
305,0
2325
2350
3300
2350
3300
2350
3300
5,54
5,54
5,76
5,80
218,4%
218,4%
227,3%
229,1%
6,41
6,13
6,49
6,62
2350
3300
488,0
483,0
498,0
493,0
305,0
374,0
315,0
384,0
2350
3300
Centrifugo
Inverter
3320
3340
3320
3340
3320
3340
5,51
5,49
5,62
5,71
217,5%
216,5%
221,9%
225,4%
6,26
6,33
6,57
6,50
3320
3340
568,0
727,0
577,0
737,0
470,0
565,0
479,0
575,0
3320
3340
3350
4325
3350
4325
3350
4325
5,57
5,35
5,73
5,62
219,8%
211,0%
226,3%
221,6%
6,28
6,12
6,47
6,40
3350
4325
727,0
797,0
737,0
797,0
565,0
720,0
575,0
720,0
3350
4325
SEER - 12/7 (EN14825: 2018) con ventilatori inverter (1)
SEER
Efficienza stagionale
A,E
W/W
N,U
W/W
A,E
%
N,U
%
5,15
5,35
203,1%
211,0%
SEPR - (EN 14825: 2018) Alta temperatura con ventilatori inverter (2)
SEPR
A,E
W/W
6,31
N,U
W/W
6,47
(1) Calcolo eseguito con portata d’acqua FISSA e temperatura d’uscita VARIABILE.
(2) Calcolo eseguito con portata d’acqua FISSA.
DATI ELETTRICI
Taglia
Dati elettrici
Corrente massima (FLA)
Corrente di spunto (LRA)
DATI TECNICI GENERALI
Taglia
Compressore
Tipo
Regolazione compressore
Numero
Circuiti
Refrigerante
Carica refrigerante (1)
Scambiatore lato utenza
Tipo
Numero
Attacchi idraulici
Attacchi (in/out)
Diametro (in/out)
Ventilatore
Tipo
Motore ventilatore
Numero
Portata aria
A,E
A
N,U
A
A,E
A
N,U
A
A,E,N,U
tipo
A,E,N,U
Tipo
1300
165,0
165,0
36,0
36,0
1300
A,E,N,U
A,E,N,U
A,E,N,U
A,E
N,U
A,E,N,U
A,E,N,U
n°
1
1
2
2
2
3
3
3
3
4
n°
1
1
1
2
1
1
2
1
1
2
tipo
kg
81,0
kg
81,0
tipo
166,0
166,0
152,0
163,0
243,0
254,0
R134a
285,0
264,0
296,0
275,0
Fascio tubiero
306,0
317,0
317,0
328,0
387,0
398,0
398,0
398,0
n°
1
1
1
1
1
1
1
1
1
1
A,E,N,U
Tipo
Giunti scanalati
A,E
Ø
3”
4”
6”
6”
6”
6”
6”
6”
8”
8”
N,U
Ø
6”
6”
6”
6”
6”
6”
6”
6”
8”
8”
A,E,N,U
tipo
Assiali
A,E,N,U
tipo
Inverter
A,E
n°
6
8
10
12
14
16
18
20
20
22
N,U
n°
6
8
12
14
16
18
20
22
22
22
A,E
m3/h
112920
150560
188200
225840
263480
301120
338760
376400
376400
414040
N,U
m3/h
112920
150560
225840
263480
301120
338760
376400
414040
414040
414040
(1) La carica riportata in tabella è un valore stimato e preliminare. Il valore finale della carica di refrigerante è riportato nella targhetta tecnica dell’unità. Per maggiori informazioni contattare sede.
Potenza frigorifera
kW
328,1
443,8
633,5
758,5
876,4
985,0
1088,0
1154,9
1256,9
1342,4
Potenza assorbita
kW
92,3
124,4
178,8
213,2
245,5
275,4
306,8
326,3
358,1
386,6
Corrente assorbita totale a freddo
A
145,7
200,9
281,4
341,6
401,9
437,1
487,3
522,6
582,6
627,6
EER
W/W
3,56
3,57
3,54
3,56
3,57
3,58
3,55
3,54
3,51
3,47
Portata acqua utenza
l/h
56452
76308
108940
130424
150669
169356
187070
198556
216075
230760
Perdita di carico lato utenza
kPa
51
25
49
50
30
53
56
53
36
38
Potenza frigorifera
kW
328,1
443,8
633,5
758,5
876,4
985,0
1088,0
1154,9
1256,9
1342,4
Potenza assorbita
kW
92,3
124,4
178,8
213,2
245,5
275,4
306,8
326,3
358,1
386,6
Corrente assorbita totale a freddo
A
145,7
200,9
281,4
341,6
401,9
437,1
487,3
522,6
582,6
627,6
EER
W/W
3,56
3,57
3,54
3,56
3,57
3,58
3,55
3,54
3,51
3,47
Portata acqua utenza
l/h
56452
76308
108940
130424
150669
169356
187070
198556
216075
230760
Perdita di carico lato utenza
kPa
51
25
49
50
30
53
56
53
36
38
A
R
I
A
-
A
C
Q
U
A