TBG - (U)
Taglia
1230
1310
Prestazioni in raffreddamento 12 °C / 7 °C (1)
(1) Dati EN 14511:2022; Acqua scambiatore lato utenza 12 °C / 7 °C; Aria esterna 35 °C
TBG - (N)
Taglia
1230
1310
Prestazioni in raffreddamento 12 °C / 7 °C (1)
(1) Dati EN 14511:2022; Acqua scambiatore lato utenza 12 °C / 7 °C; Aria esterna 35 °C
2230
2230
2230
5,76
5,97
227,5%
235,9%
5,99
6,18
2230
229,0
239,0
151,0
161,0
2230
2270
2270
2270
5,44
5,71
214,6%
225,2%
6,54
6,78
2270
294,0
304,0
220,0
230,0
2270
2310
3270
2310
3270
2310
3270
5,85
5,70
6,04
5,80
231,1%
225,1%
238,7%
229,0%
6,35
6,60
6,56
6,73
2310
3270
359,0
408,0
368,0
418,0
230,0
180,0
239,0
190,0
2310
3270
Centrifugo
Inverter
3280
3310
3280
3310
3280
3310
5,77
5,78
5,89
5,93
227,6%
228,3%
232,5%
234,0%
6,05
6,07
6,20
6,23
3280
3310
528,0
538,0
538,0
547,0
249,0
424,0
259,0
433,0
3280
3310
4270
4310
4270
4310
4270
4310
5,61
5,60
5,81
5,71
221,5%
220,8%
229,2%
225,5%
5,98
5,97
6,17
6,09
4270
4310
587,0
707,0
597,0
707,0
209,0
608,0
219,0
608,0
4270
4310
Potenza frigorifera
kW
230,7
324,2
439,6
511,1
604,5
709,0
807,9
906,9
1011,3
1112,5
Potenza assorbita
kW
65,3
91,2
124,4
143,9
170,1
201,3
230,6
257,3
290,2
323,2
Corrente assorbita totale a freddo
A
105,7
150,9
206,2
236,4
276,6
331,9
392,1
427,3
477,6
537,6
EER
W/W
3,53
3,55
3,53
3,55
3,55
3,52
3,50
3,52
3,49
3,44
Portata acqua utenza
l/h
39688
55753
75597
87882
103946
121900
138909
155919
173873
191260
Perdita di carico lato utenza
kPa
37
32
32
33
38
39
39
41
39
42
Potenza frigorifera
kW
230,7
324,2
439,6
511,1
604,5
709,0
807,9
906,9
1011,3
1112,5
Potenza assorbita
kW
65,3
91,2
124,4
143,9
170,1
201,3
230,6
257,3
290,2
323,2
Corrente assorbita totale a freddo
A
105,7
150,9
206,2
236,4
276,6
331,9
392,1
427,3
477,6
537,6
EER
W/W
3,53
3,55
3,53
3,55
3,55
3,52
3,50
3,52
3,49
3,44
Portata acqua utenza
l/h
39688
55753
75597
87882
103946
121900
138909
155919
173873
191260
Perdita di carico lato utenza
kPa
37
32
32
33
38
39
39
41
39
42
INDICI ENERGETICI (REG. 2016/2281 UE)
Taglia
SEER - 12/7 (EN14825: 2018) con ventilatori inverter (1)
1230
1310
SEER
Efficienza stagionale
A,E
W/W
N,U
W/W
A,E
%
N,U
%
5,44
5,63
214,6%
222,3%
6,34
6,47
1230
115,0
125,0
26,0
36,0
1230
5,52
6,03
217,6%
238,0%
5,98
6,21
1310
180,0
189,0
36,0
45,0
1310
SEPR - (EN 14825: 2018) Alta temperatura con ventilatori inverter (2)
SEPR
A,E
W/W
N,U
W/W
(1) Calcolo eseguito con portata d’acqua FISSA e temperatura d’uscita VARIABILE.
(2) Calcolo eseguito con portata d’acqua FISSA.
DATI ELETTRICI
Taglia
Dati elettrici
Corrente massima (FLA)
Corrente di spunto (LRA)
DATI TECNICI GENERALI
Taglia
Compressore
Tipo
Regolazione compressore
Numero
Circuiti
Refrigerante
Carica refrigerante (1)
Scambiatore lato utenza
Tipo
Numero
Attacchi idraulici
Attacchi (in/out)
Diametro (in/out)
Ventilatore
Tipo
Motore ventilatore
Numero
Portata aria
A,E
A
N,U
A
A,E
A
N,U
A
A,E,N,U
A,E,N,U
A,E,N,U
A,E,N,U
A,E,N,U
A,E
N,U
A,E,N,U
A,E,N,U
A,E,N,U
A,E,N,U
A,E,N,U
A,E,N,U
tipo
Tipo
n°
1
1
2
2
2
3
3
3
3
4
n°
1
1
1
2
1
2
1
1
2
2
tipo
kg
kg
tipo
71,0
82,0
110,0
121,0
142,0
153,0
177,0
188,0
R1234ze
188,0
254,0
198,0
265,0
Fascio tubiero
265,0
307,0
318,0
276,0
286,0
328,0
328,0
328,0
n°
1
1
1
1
1
1
1
1
1
1
Tipo
Ø
3”
tipo
tipo
Giunti scanalati
4”
5”
6”
6”
6”
6”
6”
6”
6”
Assiali
Inverter
A,E
n°
4
6
8
10
12
14
16
18
20
22
N,U
n°
6
8
10
12
14
16
18
20
22
22
A,E
m3/h
75280
112920
150560
188200
225840
263480
301120
338760
376400
414040
N,U
m3/h
112920
150560
188200
225840
263480
301120
338760
376400
414040
414040
(1) La carica riportata in tabella è un valore stimato e preliminare. Il valore finale della carica di refrigerante è riportato nella targhetta tecnica dell’unità. Per maggiori informazioni contattare sede.
TBG-CO_I_UN50_06
www.aermec.com
597
A
R
I
A
-
A
C
Q
U
A