760
www.aermec.com
WFGI-HP-W_I_UN50_08
WFGI 6703 - 9603 - modello (H) versione ° - gas R1234ze
Taglia
Modello: H
Prestazioni in raffreddamento 12 °C / 7 °C (1)
Prestazioni in riscaldamento 40 °C / 45 °C (2)
(1) Dati 14511:2022; Acqua lato utenza 12 °C / 7 °C; Acqua lato sorgente 30 °C / 35 °C
(2) Dati 14511:2022; Acqua lato utenza 40 °C / 45 °C; Acqua lato sorgente 10 °C / 7 °C
Indici energetici (Reg. 2016/2281 UE)
Taglia
1101
Modello: H
SEER - 12/7 (EN14825: 2018) (1)
Efficienza stagionale
%
314,30
SEER
W/W
7,93
SEPR - (EN 14825: 2018) Alta temperatura (2)
SEPR
W/W
9,10
(1) Calcolo eseguito con portata d’acqua VARIABILE e temperatura d’uscita VARIABILE.
(2) Calcolo eseguito con portata d’acqua VARIABILE.
6703
7203
8403
9603
Taglia
Modello: H
SEER - 12/7 (EN14825: 2018) (1)
Efficienza stagionale
SEER
SEPR - (EN 14825: 2018) Alta temperatura (2)
SEPR
°
A
°
A
°
A
%
2502
-
2802
-
4802
-
-
-
287.7% 286.9% 287.6% 281.6%
1251
316,20
7,98
9,00
3202
-
1401
1601
304,40
314,40
7,69
7,94
8,70
8,90
3602
4202
-
-
1801
2101
2401
296,40
301,70
310,30
7,49
7,62
7,83
8,40
8,40
8,80
5602
6402
6703
7203
2801
3201
314,20
317,80
%
294.9% 295.7% 300.5% 291.4% 301.0% 304.5% 309.3% 298.9% 302.4% 297.7% 302.9% 295.0%
W/W
-
-
-
-
-
-
-
-
7,27
7,25
7,27
7,12
W/W
7,45
7,47
7,59
7,36
7,60
7,69
7,81
7,55
7,64
7,52
7,65
7,45
W/W
-
-
-
-
-
-
-
-
8,20
8,20
8,30
8,30
W/W
8,60
8,60
8,50
8,60
8,50
8,60
8,50
8,60
8,60
8,50
8,70
8,70
(1) Calcolo eseguito con portata d’acqua VARIABILE e temperatura d’uscita VARIABILE.
(2) Calcolo eseguito con portata d’acqua VARIABILE.
Taglia
1101
1251
1401
Modello: H
UE 813/2013 prestazioni in condizioni climatiche medie (average) - 55 °C - Pdesignh ≤ 400 kW (1)
Pdesignh
SCOP
ηsh
°
kW
-
-
-
A
kW
296,00
348,00
395,00
°
W/W
-
-
-
A
W/W
5,45
5,43
5,23
°
%
-
-
-
A
%
210
209
201
(1) Efficienze in applicazioni per media temperatura (55°C)
Dati elettrici
Taglia
Modello: H
Dati elettrici
Corrente massima (FLA)
Corrente di spunto (LRA)
°
A
°
A
1101 1251 1401 1601 1801 2101 2401 2502 2801 2802 3201 3202 3602 4202 4802 5602 6402 6703 7203 8403 9603
A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-853,0939,01047,01178,0
A 155,0 177,0 201,0 222,0 262,0 296,0 349,0 343,0 390,0 389,0 415,0 422,0 488,0 559,0 644,0 719,0 797,0 853,0 939,0 1047,0 1178,0
A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-1179,01297,01527,01737,0
A 23,0 23,0 23,0 23,0 23,0 23,0 23,0 494,0 23,0 545,0 23,0 661,0 730,0 885,0 1002,0 1198,0 1357,0 1179,0 1297,0 1527,0 1737,0
7,93
8,60
8,02
8,90
8403
9603
Potenza frigorifera
kW
1298,6
1433,8
1544,1
1739,6
Potenza assorbita
kW
252,7
280,5
312,9
362,4
Corrente assorbita totale a freddo
A
449,0
491,0
553,0
649,0
EER
W/W
5,14
5,11
4,93
4,80
Portata acqua sorgente
l/h
265376
293300
317856
359510
Perdita di carico lato sorgente
kPa
44
39
34
41
Portata acqua utenza
l/h
223228
246460
265406
299001
Perdita di carico lato utenza
kPa
27
29
22
26
Potenza termica
kW
1433,5
1584,7
1718,0
1945,1
Potenza assorbita
kW
300,7
334,3
369,6
428,4
Corrente assorbita totale a caldo
A
530,0
579,0
649,0
761,0
COP
W/W
4,77
4,74
4,65
4,54
Portata acqua utenza
l/h
249013
275290
298460
337909
Perdita di carico lato utenza
kPa
39
35
30
36
Portata acqua sorgente
l/h
331388
365876
394002
443875
Perdita di carico lato sorgente
kPa
59
64
49
58
A
C
Q
U
A
-
A
C
Q
U
A