760

www.aermec.com

WFGI-HP-W_I_UN50_08

WFGI 6703 - 9603 - modello (H) versione ° - gas R1234ze

Taglia

Modello: H

Prestazioni in raffreddamento 12 °C / 7 °C (1)

Prestazioni in riscaldamento 40 °C / 45 °C (2)

(1) Dati 14511:2022; Acqua lato utenza 12 °C / 7 °C; Acqua lato sorgente 30 °C / 35 °C

(2) Dati 14511:2022; Acqua lato utenza 40 °C / 45 °C; Acqua lato sorgente 10 °C / 7 °C

Indici energetici (Reg. 2016/2281 UE)

Taglia

1101

Modello: H

SEER - 12/7 (EN14825: 2018) (1)

Efficienza stagionale

%

314,30

SEER

W/W

7,93

SEPR - (EN 14825: 2018) Alta temperatura (2)

SEPR

W/W

9,10

(1) Calcolo eseguito con portata d’acqua VARIABILE e temperatura d’uscita VARIABILE.

(2) Calcolo eseguito con portata d’acqua VARIABILE.

6703

7203

8403

9603

Taglia

Modello: H

SEER - 12/7 (EN14825: 2018) (1)

Efficienza stagionale

SEER

SEPR - (EN 14825: 2018) Alta temperatura (2)

SEPR

°

A

°

A

°

A

%

2502

-

2802

-

4802

-

-

-

287.7% 286.9% 287.6% 281.6%

1251

316,20

7,98

9,00

3202

-

1401

1601

304,40

314,40

7,69

7,94

8,70

8,90

3602

4202

-

-

1801

2101

2401

296,40

301,70

310,30

7,49

7,62

7,83

8,40

8,40

8,80

5602

6402

6703

7203

2801

3201

314,20

317,80

%

294.9% 295.7% 300.5% 291.4% 301.0% 304.5% 309.3% 298.9% 302.4% 297.7% 302.9% 295.0%

W/W

-

-

-

-

-

-

-

-

7,27

7,25

7,27

7,12

W/W

7,45

7,47

7,59

7,36

7,60

7,69

7,81

7,55

7,64

7,52

7,65

7,45

W/W

-

-

-

-

-

-

-

-

8,20

8,20

8,30

8,30

W/W

8,60

8,60

8,50

8,60

8,50

8,60

8,50

8,60

8,60

8,50

8,70

8,70

(1) Calcolo eseguito con portata d’acqua VARIABILE e temperatura d’uscita VARIABILE.

(2) Calcolo eseguito con portata d’acqua VARIABILE.

Taglia

1101

1251

1401

Modello: H

UE 813/2013 prestazioni in condizioni climatiche medie (average) - 55 °C - Pdesignh ≤ 400 kW (1)

Pdesignh

SCOP

ηsh

°

kW

-

-

-

A

kW

296,00

348,00

395,00

°

W/W

-

-

-

A

W/W

5,45

5,43

5,23

°

%

-

-

-

A

%

210

209

201

(1) Efficienze in applicazioni per media temperatura (55°C)

Dati elettrici

Taglia

Modello: H

Dati elettrici

Corrente massima (FLA)

Corrente di spunto (LRA)

°

A

°

A

1101 1251 1401 1601 1801 2101 2401 2502 2801 2802 3201 3202 3602 4202 4802 5602 6402 6703 7203 8403 9603

A

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-853,0939,01047,01178,0

A 155,0 177,0 201,0 222,0 262,0 296,0 349,0 343,0 390,0 389,0 415,0 422,0 488,0 559,0 644,0 719,0 797,0 853,0 939,0 1047,0 1178,0

A

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-1179,01297,01527,01737,0

A 23,0 23,0 23,0 23,0 23,0 23,0 23,0 494,0 23,0 545,0 23,0 661,0 730,0 885,0 1002,0 1198,0 1357,0 1179,0 1297,0 1527,0 1737,0

7,93

8,60

8,02

8,90

8403

9603

Potenza frigorifera

kW

1298,6

1433,8

1544,1

1739,6

Potenza assorbita

kW

252,7

280,5

312,9

362,4

Corrente assorbita totale a freddo

A

449,0

491,0

553,0

649,0

EER

W/W

5,14

5,11

4,93

4,80

Portata acqua sorgente

l/h

265376

293300

317856

359510

Perdita di carico lato sorgente

kPa

44

39

34

41

Portata acqua utenza

l/h

223228

246460

265406

299001

Perdita di carico lato utenza

kPa

27

29

22

26

Potenza termica

kW

1433,5

1584,7

1718,0

1945,1

Potenza assorbita

kW

300,7

334,3

369,6

428,4

Corrente assorbita totale a caldo

A

530,0

579,0

649,0

761,0

COP

W/W

4,77

4,74

4,65

4,54

Portata acqua utenza

l/h

249013

275290

298460

337909

Perdita di carico lato utenza

kPa

39

35

30

36

Portata acqua sorgente

l/h

331388

365876

394002

443875

Perdita di carico lato sorgente

kPa

59

64

49

58

A

C

Q

U

A

-

A

C

Q

U

A