MPG_DH
Prestazioni in raffrescamento nominali
Prestazioni in riscaldamento nominali
Unità interna
Tipo di ventilatore
Tipo
Potenza assorbita
W
Pressione statica utile
Massima
Pa
Portata d’aria
Minima
m3/h
Media
m3/h
Massima
m3/h
Turbo
m3/h
Centrifugo inverter
MPG250DH
MPG350DH
MPG500DH
MPG700DH
Potenza frigorifera (1)
kW
2,65
3,50
5,00
7,00
Umidità asportata
l/h
0,8
1,4
1,8
2,5
Potenza termica (2)
kW
2,80
4,00
5,50
8,00
50
50
75
80
60
60
60
125
Pressione sonora (1 m) (3)
Turbo
Minima
Media
Massima
Potenza sonora (4)
Minima
Media
Massima
Turbo
Unità interna
Diametro scarico condensa
Alimentazione
Alimentazione unità interna
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
mm
550
410
610
480
670
560
700
650
41,0
39,0
35,0
33,0
37,0
35,0
39,0
37,0
51,0
49,0
53,0
51,0
55,0
53,0
57,0
55,0
26,0
26,0
750
900
790
1000
840
1200
880
1500
41,0
45,0
37,0
36,0
38,0
38,0
39,0
40,0
53,0
53,0
54,0
55,0
55,0
57,0
57,0
62,0
26,0
26,0
(1) Raffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo;
(2) Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo;
(3) Pressione sonora misurata in camera semianecoica a 1 m di distanza frontale.
(4) Potenza sonora calcolata in campo libero in accordo con UNI EN ISO 3744.
Potenza sonora misurata in campo libero in accordo con UNI EN ISO 3744.
220-240V ~ 50Hz
lunghezza linee frigorifere 5 m.
lunghezza linee frigorifere 5 m.
MPG_I_UN50_07
www.aermec.com
909
S
P
L