Differential Temperature Controller
LK 162 SmartStove®
• With the alarm function in case of over temperature,
you can enjoy the warmth without worrying
TECHNICAL DATA
Voltage
230 VAC, 50 Hz
Power consumption
3,5 VA
Protection type
IP 20
Protection class
II
Display
TFT backlit colour display, 47 x 35 mm
Triac outputs
230 VAC ± 10%, 1 A, 200 VA
Relay output
Max. 240 VAC, 4 A
Sensors
PT 1000
High-efficiency pump
Analog output 0 -10 V, max. 10 mA
PWM output 100 Hz - 2 kHz
Type approval certificate
CE
LK 162 SmartStove® is a biomass controller for multi-fuel
water containing stoves with buffer tanks. The controller has a
number of preset hydraulic systems for different installations.
FEATURES
• Acoustic alarm and indication in the display if over tempera-
ture should occur in stove or buffer tank
• A temperature sensor in the stove controls the charge pump
of the loading unit which means that no fluegas thermostat is
needed
• Pump delay function. The charge pump in the loading unit
does not start until the stove has reached a certain temper-
ature. This saves energy, prevents tarring and considerably
prolongs the life-time of the stove
• Dynamic pump control can be activated when the loading unit
is equipped with a speed-controlled pump. The pumpcontrol
keeps the flow at a constant temperature
• Economy or comfort mode can be selected to optimize energy
efficiency in the potable hot water boiler and/or in the heating
system
• Controls an additional heat source
• Delay function for the additional heat source
• 7 hydraulic systems which can be mirrored
• 2 outputs for speed-controlled pumps with PWM and/ or
analogue signal
• 6 terminals for temperature sensors
• 1 floating change-over contact
• SD card slot for data logging and software update
• Legionella prevention
• Pump exercise
• Freeze protection
For indication of the active hydraulic system and the current
temperatures in stove and buffer tank the controller is equipped
with a coloured full graphics display which is permanently
backlit.
LK 162 SmartStove® can control the charge pump of a loading
unit, the circulator in a heating loop, high-efficiency pumps and
an additional heat source.
103