TECHNICAL DATA
Angle of rotation
90°/360°
Leakage
< 0.1% of Kvs at 100 kPa
Operation time
12 seconds (90°)
Max. working pressure
1.0 MPa (10 bar)
Max. differential pressure
100 kPa (1 bar)
Working temperature
Min. 5 °C/Max. 80 °C
(90 °C briefly)
Ambient temperature
Min. 1 °C/Max. 60 °C
Thread standard
Rp - female thread,
G - male thread, ISO 228/1
Protection type
IP 44
Media
Water - Glycol mixture max. 50%
Ethanol mixture max. 30%
Electrical connection
Fixed wire
Signal connector
Single pole SPST
Cable specification
Dimension 3 x 0,75 mm2
Wire colours
Blue, brown, black
External insulation
PVC
Actuator
7 VA, 230 VAC, 50 Hz
Material valve body
Brass EN 12165 CW617N
Material external cover
Brass EN 12164 CW614N
Material slide/spindle
PPS Composite
Type approval certificate
CE (Actuator only)
Zone Valves
LK 525 MultiZone 2W
• Simple and flexible assembly with clip system
• Actuators are available as normally closed (NC) or
normally open (NO). Direction is displayed on the
actuator
Open
Closed
Open
Closed Closed
WIRING DIAGRAM
Closed
Valve and motor are available in closed or open position. (NC; Normally
Closed or NO; Normally Open)
LK 525 MultiZone is a motorized 2-way zone valve for applica-
tion in heating systems in which the flow through one or more
zones is to be controlled. The zone valve has On/Off control and
is designed with a turning slide which allows it to withstand a
larger pressure difference and reduces the risk of it stalling
after a long intermission. On the upper surface of the actuator is
an indicator that shows which port is open or closed.
The zone valve must not be installed with the motor underneath
the valve unit.
In case of a power failure, the valve cone stays in its current po-
sition. When the power is switched off, the valve can be manual-
ly set. Remove the motor and turn the spindle to your selected
position. When the power is restored, turn the valve back to its
original position and reinstall the motor.
Please note that the motor can be installed in only one position.
10,0
1,0
0,1
Kvs (m3/h)
0,1
1,0
10,0
100,0
Pressure Drop (kPa)
CAPACITY DIAGRAM
109
F
l
o
w
(
m
3
/
h
)