Shunt Group
LK 422 Manifold Shunt Tmax
•
Suitable for left-hand and right-hand mounting
P (kPa)
70
60
50
40
30
20
10
V1
LK Manifold Shunt Tmax is used in systems with a main pump.
The shunt unit can be mounted directly to LK Manifold RF from
the left or right. The shunt unit is fitted as standard with a
constant thermostat controlled feed temperature as well as an
automatic speed controlled pump for reduced energy consump-
tion and quieter operation. The guideline capacity of this shunt
unit is a maximum of 130 m2 floor heating surface. The capacity
is dependent on heat requirement, laying procedure etc.
LK 422 can be mounted directly onto the manifold from the right
or left. A manifold supply pipe for use when mounting to the left
of the manifold is supplied. When fitting from the right, shorten
the supply pipe by about 50 mm, reposition the thermometers
and the pump through 180°.
TECHNICAL DATA
Voltage
1 phase 230V AC, -15 % / +10 %,
50 Hz, PE
Max. working pressure
0.6 MPa (6 bar)
Max. differential pressure
0.1 MPa (1 bar)
Working temperature
Primary: Min. 5 °C/Max. 90 °C
Secondary: Min. 30 °C/Max. 65 °C
Ambient temperature
Max. 70 °C
Thread standard
G - male thread,
G - female thread
Protection type
IP44
Media
Water - Glycol mixture max. 50%
Ethanol mixture max. 30%
Circulating pump
Grundfos UPM3 AUTO 15-70
Material valve body
Nickel-plated Brass EN 12165
CW617N
Material pipe
Supply pipe: Stainless steel EN
1.4404
PUMP CHARACTERISTICS
CONSTANT PRESSURE 1
Cp3
Cp2
Cp1
CC III
CC II
CCI
CONSTANT PRESSURE 2
CONSTANT PRESSURE 3MAX
CC MAX
VF
V2
156
0
0
5
10
15
20
25
30
35
40
Q (l/min)