Loading unit
LK 811 ThermoMat 2.0 W
• Adjustable return temperature
• Electronic regulation ensures an easy operation
TECHNICAL DATA
Voltage
Power consumption
Max. boiler efficiency
Max. working pres-
sure
Working temperature
Return temperature
Ambient temperature
Thread standard
Media
Circulating pump
Material, valve body
Material, insulation
230 VAC 50 Hz
10-75 W, depending on pump speed
65 kW at 20 °C ΔT
0.6 MPa (6 bar)
Min. 5 °C/Max. 95 °C
5-99 °C with LK 100 SmartComfort CT
Min. 5 °C/Max. 60 °C
Rp - female thread
Water - Glycol mixture max. 50%
Wilo Para /6 SC FS14,
Wilo Para /8 SC FS14
Brass EN 1982 CB753S
Expanded Polypropylene EPP
THE FUNCTION OF THE LOADING UNIT DURING THE
DIFFERENT PHASES OF HEATING:
1. HEAT UP PHASE
The water circulates between boiler and
loading unit while the temperature of the
boiler is rising.
2. LOADING PHASE
The electronic temperature controller starts
to open the mixing valve at the chosen tem-
perature and allows return water from the
storage tank to be mixed with supply water
before it returns to the boiler. The return
temperature to the boiler is kept constant.
3. END PHASE
The mixing valve is fully open towards the
storage tank. This results in an optimal
transfer of heat from the boiler and the
storage tank is filled with supply water.
When the boiler has cooled the electron-
ic controller LK 100 SmartComfort CT
prevents re-circulation from storage tank
to boiler.
4. SELF-CIRCULATION WITH CHECK
VALVE
Self-circulation will be obtained as soon
as the fire has gone out and the circulating
pump has stopped. The remaining hot water
is loaded to the storage tank. In case of power
failure or pump breakdown the check valve
automatically opens to allow self-circulation.
The check valve also stops recirculation from
storage tank to boiler.
LK 811 ThermoMat 2.0 W is a loading unit for heating applica-
tions with solid fuel boilers and storage tanks. The loading unit is
intended to ensure a high return temperature as well as an optimal
temperature stratification in the storage tank, thus increasing the
efficiency of the system. Tarring and condensation are prevented
which prolongs boiler life.
The LK 811 ThermoMat 2.0 W is a compact design with an integrat-
ed low-energy circulating pump and a mixing valve that regulates
on two ports. The loading unit has three ball valves to simplify
installation and maintenance and an insulation to minimize heat
loss. Three thermometers that allow for simple control of the
loading process can be ordered as accessories.The loading unit
is available in two versions - with or without check valve. With a
check valve the functions described under phase 4 will be obtained.
The loading unit is reversible and can easily be adapted for mount-
ing to the right or left of the boiler. Thanks to the three ball valves
any part can be changed without draining the system in case of
servicing.
LK 811 ThermoMat 2.0 W is available with or without an electron-
ic temperature controller. Mounting kits for controllers of other
brands are available - see section Temperature Controllers -
Mounting Kits.
Please contact our Sales Department for more information.
16