Valve combination

LK 322 CoolUnit

• Insulation against condensation

• Energy effective way for free cooling

• Recharge the borehole during the summer

TECHNICAL DATA

Max. working pressure

Working temperature

Thread standard

Media

Material valve body

Material sealing

0,6 MPa (6 bar)

Min. -20 °C/Max. 80 °C

G - male thread

Water - Glycol mixture max. 50%

Brass EN 12165 CW617N

EPDM

LK 322 CoolUnit is a valve combination that utilises the cold

available in a system with a geothermal heat pump.

By running the brine in the collector hose to a fan coil, you can

cool your home with the cold naturally found in the ground. In

addition, the borehole is recharged during the summer, which

increases the performance of the heat pump.

The LK 322 CoolUnit also contains a non-return valve to ensure

the liquid is run in the right direction when fitting the shunt

group with its own circulation pump. See LK HydronicGroup

C/C 90 and 125 Cooling for a suitable shunt group.

The LK 322 have two 1” alt. 11⁄4” male thread for connection to the

collector pipe. Two ball valves with 3⁄4” male thread for connection

to convector pipe.

LK 322 - Male thread

�� � ��

Article no.

092366

092367

Dim.

G 1”

G 11⁄4”

Kvs m3/h

9.5

16

A mm

168

168

C mm

112

112

Weight kg

1.6

1.7

� ��

� ���

� ��

� ���

B mm

110

110