MODELLO
HP
Moduli
Alimentazione
Raffreddamento
Riscaldamento
Livelli Sonori *
4
Connettività
Diametro
tubazioni
refrigerante
Ventilatore
Compressore
Dimensioni
esterne
Peso netto
Refrigerante
PURY-P450YNW-A1(-BS)
PURY-P500YNW-A1(-BS)
PURY-P400YSNW-A1(-BS)
PURY-P450YSNW-A1(-BS)
PURY-P500YSNW-A1(-BS)
18
20
16
18
20
EER
SEER
Campo operativo
di temperatura
Interno
Esterno
3,02
6,32
+15~+24
-5~+52
56,0/63
14,47/17,50
3,87/3,60
4,05
+15~+27
-20~+15,5
63,5/64,5 (82/84)
50-150%
P10-P250/1-50
22,2
28,58
Propeller fan x 2
1858(1798)x1750x740
4,12
7,39
+15~+24
-5~+52
45,0/50,0
9,22/10,98
4,88/4,55
3,84
+15~+27
-20~+15,5
62/62 (79/81)
50-150%
P10-P250/1-40
22,2
28,58
Propeller fan x 2
1858(1798)x920x740
1858(1798)x920x740
3,93
7,09
+15~+24
-5~+52
50,0/56,0
10,82/12,93
4,62/4,33
3,89
+15~+27
-20~+15,5
63/63,5 (81/83)
50-150%
P10-P250/1-45
22,2
28,58
Propeller fan x 2
1858(1798)x920x740
1858(1798)x920x740
3,74
6,84
+15~+24
-5~+52
56,0/63,0
12,81/15,32
4,37/4,11
3,93
+15~+27
-20~+15,5
63,5/64 (81/83)
50-150%
P10-P250/1-50
22,2
28,58
Propeller fan x 2
1858(1798)x920x740
1858(1798)x920x740
Capacità nominale*
2
/
Capacità nominale massima*
3
Potenza assorbita /
Potenza assorbita max.
COP/COP max
SCOP
Campo operativo
di temperatura
Interno
Esterno
Pressione Sonora (Potenza sonora)
Capacità totale
Modello/Quantità
Liquido
Gas
CITY MULTI
MODELLO
HP
Moduli
Alimentazione
Raffreddamento
Riscaldamento
Livelli Sonori *
4
Connettività
Diametro
tubazioni
refrigerante
Ventilatore
Compressore
Dimensioni
esterne
Peso netto
Refrigerante
PURY-P(250+300)YNW-A1
PURY-P(300+300)YNW-A1
PURY-P(300+350)YNW-A1
PURY-P(350+350)YNW-A1
PURY-P(350+400)YNW-A1
3-fase 380-415V 50Hz
SCOP
Campo operativo
di temperatura
Interno
Esterno
Pressione Sonora (Potenza sonora)
Capacità totale
Modello/Quantità
Liquido
Gas
CITY MULTI
V/Hz/n°
kW
°C BU
°C BS
kW
kW
°C BS
°C BU
dB(A)
mm
mm
V/Hz/n°
kW
°C BU
°C BS
kW
kW
°C BS
°C BU
dB(A)
mm
mm
PURY-P450YNW-A1
PURY-P500YNW-A1
PURY-P(200+200)YNW-A1
PURY-P(200+250)YNW-A1
PURY-P(250+250)YNW-A1
3-fase 380-415V 50Hz
Capacità nominale *
1
Potenzaassorbita
kW
14,83
18,54
10,92
12,72
14,97
50,0
3,37
6,40
+15~+24
-5~+52
50,0/56,0
12,46/15,42
4,01/3,63
4,03
+15~+27
-20~+15,5
65,5/70 (83/89)
50-150%
P10-P250/1-45
22,2
28,58
Propeller fan x 2
mm
1858(1798)x1240x740
56,0
45,0
50,0
56,0
Tipo x quantità
Portataaria
m
3
/min
315
295
170+170
170+185
185+185
Tipo
Scroll ermetico inverter
Resamotore
kW
12,4
14,2
3,7+3,7
3,7+5,5
5,5+5,5
A(A*
5
)xLxP
kg
289
CaricaR410A
kg
10,8
10,8
10,4
10,4
10,4
CO2eq.*
6
Tons
22,55
22,55
21,71
21,71
21,71
335
PURY-P550YSNW-A1(-BS)
PURY-P600YSNW-A1(-BS)
PURY-P650YSNW-A1(-BS)
PURY-P700YSNW-A1(-BS)
PURY-P750YSNW-A1(-BS)
22
24
26
28
30
Capacità nominale *
1
Potenzaassorbita
kW
17,11
19,06
20,44
22,66
26,07
EER
SEER
Campo operativo
di temperatura
Interno
Esterno
3,68
6,58
+15~+24
-5~+52
63,0/69,0
15,0/17,42
4,20/3,96
3,81
+15~+27
-20~+15,5
64/68 (83/87)
50-150%
P10-P250/2-50
22,2
28,58
Propeller fan x 2
mm
1858(1798)x920x740
1858(1798)x920x740
3,62
6,38
+15~+24
-5~+52
69,0/76,5
17,07/20,07
4,04/3,81
3,69
+15~+27
-20~+15,5
64/70 (83/89)
50-150%
P10-P250/2-50
22,2
28,58
Propeller fan x 2
1858(1798)x920x740
1858(1798)x920x740
3,57
6,26
+15~+24
-5~+52
73,0/81,5
17,76/21,05
4,11/3,87
3,65
+15~+27
-20~+15,5
65/69 (84/88)
50-150%
P10-P250/2-50
28,58
28,58
Propeller fan x 3
1858(1798)x920x740
1858(1798)x1240x740
3,53
6,27
+15~+24
-5~+52
80,0/88,0
19,13/22,44
4,18/3,92
3,61
+15~+27
-20~+15,5
65,5/67 (84/86)
50-150%
P10-P250/2-50
28,58
34,93
Propeller fan x 4
1858(1798)x1240x740
1858(1798)x1240x740
3,26
6,25
+15~+24
-5~+52
85,0/95,0
21,46/25,53
3,96/3,72
3,61
+15~+27
-20~+15,5
67/70,5 (86/90)
50-150%
P10-P250/2-50
28,58
34,93
Propeller fan x 4
1858(1798)x1240x740
1858(1798)x1240x740
Capacità nominale*
2
/
Capacità nominale massima*
3
Potenza assorbita /
Potenza assorbita max.
COP/COP max
63,0
69,0
73,0
80,0
85,0
Tipo x quantità
Portataaria
m
3
/min
185+240
240+240
240+250
250+250
250+315
Tipo
Scroll ermetico inverter
Resamotore
kW
5,5+7,3
7,3+7,3
7,3+8,7
8,7+8,7
8,7+11,7
A(A*
5
)xLxP
kg
223+225
CaricaR410A
kg
10,4
10,4
13,2
16
16
CO2eq.*
6
Tons
21,71
21,71
27,56
33,40
33,40
*
1
*
2
*
3
Condizioni nominali:
Riscaldamento : Interno 20°C BS. Esterno 7°C BS / 6°C BU. Lunghezza tubi 7.5 m, differenza livello 0 m.
Raffreddamento Interno 27°C BS / 19°C BU. Esterno 35°C BS. Lunghezza tubi 7.5 m, differenza livello 0 m.
*
2
Capacità nominale ( registrata Eurovent - Conto Termico e Detrazioni)
*
4
Valori misurati in camera anecoica. Raffreddamento-Riscaldamento
*
5
senza piedini di sostegno
*
6
GWP di HFC R410A pari a 2088 secondo regolamento 517 / 2014
I dati di SEER e SCOP sono basati in conformità allo standard di misura EN14825
225+225
225+269
269+269
269+269
214+214
214+223
223+223
LINEA R2 NEXT STAGE / PURY-P Y(S)NW-A1
61