LINEA WY / PQH(R)Y-P Y(S)LM-A1
MODELLO
HP
Moduli
Giunto di accoppiamento
Alimentazione
Raffreddamento
Riscaldamento
Pressione sonora
3
Unità int. collegabili
Ø est. attacchi refr.
Acqua circolante
Dimensioni esterne (AxLxP)
Peso netto
Carica refr. R410A*4/CO2 Eq
DOUBLE PQHY-P400YSLM-A1
PQHY-P450YSLM-A1
PQHY-P500YSLM-A1
PQHY-P550YSLM-A1
PQHY-P600YSLM-A1
16
18
20
22
24
MODELLO
HP
Moduli
Giunto di accoppiamento
Alimentazione
Raffreddamento
Riscaldamento
Pressione sonora
*3
Unità int. collegabili
Ø est. attacchi refr.
Acqua circolante
Dimensioni esterne (AxLxP)
Peso netto
Carica refr. R410A*
4
/CO
2
Eq
PQHY-P750YSLM-A1
PQHY-P800YSLM-A1
PQHY-P850YSLM-A1
PQHY-P900YSLM-A1
Campo operativo
di temperatura
Interna BU
Acqua in circolo
PQHY-P200YLM-A
PQHY-P250YLM-A
PQHY-P200YLM-A
PQHY-P200YLM-A
PQHY-P250YLM-A
PQHY-P250YLM-A
°C
15,0~24,0
15,0~24,0
15,0~24,0
15,0~24,0
15,0~24,0
°C
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
kW
50,0
56,0
63,0
69,0
76,5
Tensione/Freq./Fasi
V/Hz/n°
Capacità*
1
kW
Potenzaassorbita
kW
7,70
8,78
10,12
11,55
12,84
EER
5,84
5,69
5,53
5,45
5,37
SEER
-
-
-
-
-
kg
174+174
kg/Tons
5,0+5,0 /20,88
45,0
50,0
63,0
69,0
Capacità massima*
2
Potenzaassorbita
kW
7,94
8,97
10,16
11,31
12,75
COP
6,29
6,24
6,20
6,10
6,0
SCOP
-
-
-
-
-
Campo operativo
di temperatura
Interna BS
°C
15,0~27,0
15,0~27,0
15,0~27,0
15,0~27,0
15,0~27,0
Acqua in circolo
°C
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
Modalitànormale
dB(A)
49
50
51
55
57
Capacità totale
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
Modello/Quantità
Liquido
Gas
Portatanominale
m3/h
5,76+5,76
5,76+5,76
5,76+5,76
5,76+5,76
5,76+5,76
Range operativo portata
Calo di pressione
Volume dello scambiatore
3+3~7,2+7,2
kPa
24+24
l
5,0+5,0
3+3~7,2+7,2
24+24
5,0+5,0
1100 x 880 x 550
1100 x 880 x 550
174+174
5,0+5,0 /20,88
3+3~7,2+7,2
24+24
5,0+5,0
1100 x 880 x 550
1100 x 880 x 550
174+174
5,0+5,0 /20,88
3+3~7,2+7,2
24+24
5,0+5,0
1100 x 880 x 550
1100 x 880 x 550
174+174
5,0+5,0 /20,88
mm
P15~P250/1~34
15,88
28,58
P15~P250/1~39
15,88
28,58
P15~P250/1~43
15,88
28,58
P15~P250/2~47
15,88
28,58
P15~P250/2~50
15,88
28,58
PQHY-P350YLM-A
PQHY-P400YLM-A
PQHY-P350YLM-A
PQHY-P350YLM-A
CMY-Y100VBK3
3 fasi 380-400-415V 50Hz
56,0
3+3~7,2+7,2
24+24
5,0+5,0
1100 x 880 x 550
1100 x 880 x 550
174+174
5,0+5,0 /20,88
DOUBLE PQHY-P700YSLM-A1
28
30
32
34
36
mm
1100 x 880 x 550
1100 x 880 x 550
PQHY-P400YLM-A
PQHY-P400YLM-A
°C
15,0~24,0
15,0~24,0
15,0~24,0
15,0~24,0
15,0~24,0
°C
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
kW
50,0
56,0
63,0
69,0
76,5
Tensione/Freq./Fasi
V/Hz/n°
Capacità
*1
kW
Potenzaassorbita
kW
14,73
15,64
16,57
18,03
19,38
EER
5,43
5,43
5,43
5,32
5,21
SEER
-
-
-
-
-
Campo operativo
di temperatura
Interna BU
Acqua in circolo
80,0
85,0
96,0
101,0
Capacità massima*
2
Potenzaassorbita
kW
7,94
8,97
10,16
11,31
12,75
COP
6,29
6,24
6,20
6,10
6,0
SCOP
-
-
-
-
-
Campo operativo
di temperatura
Interna BS
°C
15,0~27,0
15,0~27,0
15,0~27,0
15,0~27,0
15,0~27,0
Acqua in circolo
°C
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
Modalitànormale
dB(A)
55
55
55
56
57
50~130% della capacità
dell’unità esterna
Modello/Quantità
P15~P250/2~50
Liquido/Gas
mm
19,05/34,93
19,05/34,93
19,05/34,93
19,05/41,28
19,05/41,28
Portatanominale
m
3
/h
7,20+7,20
7,20+7,20
7,20+7,20
7,20+7,20
7,20+7,20
Range operativo portata
Calo di pressione
Volume dello scambiatore
4,5+4,5~11,6+11,6
kPa
44+44
l
5,0+5,0
4,5+4,5~11,6+11,6
44+44
5,0+5,0
1450 x 880 x 550
1450 x 880 x 550
217+217
6,0+6,0 /25,06
4,5+4,5~11,6+11,6
44+44
5,0+5,0
1450 x 880 x 550
1450 x 880 x 550
217+217
6,0+6,0 /25,06
4,5+4,5~11,6+11,6
44+44
5,0+5,0
1450 x 880 x 550
1450 x 880 x 550
217+217
6,0+6,0 /25,06
4,5+4,5~11,6+11,6
44+44
5,0+5,0
1450 x 880 x 550
1450 x 880 x 550
217+217
6,0+6,0 /25,06
*
1
Condizioni di raffreddamento nominali: interno 27°C BS / 19°C BU. Temperatura acqua 30°C Lunghezza tubazioni 7.5m, dislivello 0m.
*
2
Condizioni di riscaldamento nominali: interno 20°C BS. Temperatura acqua 20°C Lunghezza tubazioni 7.5m, dislivello 0m.
*
3
Valori misurati in camera anecoica.
*
4
GWP di HFC R410A pari a 2088 secondo regolamento 517 / 2014
I dati di SEER e SCOP sono basati in conformità allo standard di misura EN14825
72
mm
1450 x 880 x 550
1450 x 880 x 550
kg
217+217
kg/Tons
6,0+6,0 /25,06
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
P15~P250/2~50
P15~P250/2~50
P15~P250/2~50
P15~P250/2~50
CMY-Y200VBK2
3 fasi 380-400-415V 50Hz
90,0
PQHY-P300YLM-A
PQHY-P250YLM-A
PQHY-P300YLM-A
PQHY-P300YLM-A
PQHY-P450YLM-A
PQHY-P400YLM-A
PQHY-P450YLM-A