41,0
lindab | heat recovery
Dati tecnici
Dati elettrici
Rumorosità
Lw Livello di potenza sonora misurato secondo UNI EN ISO 37
3
Ventilatore
Modello
Potenza
Alimentazione
Corrente
W
V-ph-Hz
A
Unità GEMINI O
max
is
Classe
olamento
Alimentazione Correntemax
Classe
V-ph-Hz
A
isolamento
GEMINI O 700
2 x 145
230-50/60-1
2 x 1, 2
IP54 Classe B
230-50-1
2,5
IP20
GEMINI O 1100
2 x 170
230-50/60-1
2 x 1, 4
IP54 Classe B
230-50-1
2,9
IP20
GEMINI O 1600
2 x 448
230-50/60-1
2 x 2, 8
IP54 Classe B
230-50-1
5,7
IP20
GEMINI O 2300
2 x 448
230-50/60-1
2 x 2, 8
IP54 Classe B
230-50-1
5,7
IP20
GEMINI O 3400
2 x 715
230-50/60-1
2 x 3, 1
IP54 Classe B
47 classe
230-50-1
6,3
IP20
Rumore
dalla cassa (dB)
125 Hz
250 Hz
500 Hz
1000 H z
2000 Hz
4000 Hz
8000 Hz
L
W
dB(A)
GEMINI O 700
58,0
59,0
46,0
35,0
30,0
22,0
51,8
GEMINI O 1100
66,0
66,0
55,0
46,0
41,0
33,0
31,0
59,6
GEMINI O 1600
68,0
70,0
55,0
50,0
44,0
36,0
26,0
62,8
GEMINI O 2300
67,0
74,0
60,0
57,0
52,0
44,0
34,0
66,8
GEMINI O 3400
69,0
76,0
57,0
59,0
50,0
43,0
35,0
68,6
Rumore
nel canale (dB)
125 Hz
250 Hz
500 Hz
1000 H z
2000 Hz
4000 Hz
8000 Hz
L
W
dB(A)
GEMINI O 700
67,0
68,0
54,0
53,0
51,0
47,0
45,0
61,9
GEMINI O 1100
72,0
67,0
58,0
47,0
60,1
45,0
37,0
32,0
61,6
GEMINI O 1600
73,7
84,5
64,5
59,9
55,0
45,8
76,4
GEMINI O 2300
69,0
77,0
61,0
60,0
55,0
48,0
39,0
69,3
GEMINI O 3400
76,0
78,0
60,0
61,0
56,0
51,0
43,0
70,9
Ecodesign
*Percentuale della portata nominale
Valori secondo UNI EN 1886:2008
Test leakage secondo UNI EN 13141-7
Modello
Ƞt-nvru qnom Δps ext
P
SFPint
%
m
3
/s
Pa
kW
W/(m
3
/s) W/(m
3
/s) W/(m
3
/s)
m/s
Pa
%
%
%
GEMINI O 700
80,0
0,15
200
0,32
1079
SFPint
SFPint
Velocità
Δps int Ƞfan
Leakage Leakage
lim 2016 lim 2018
frontale
interno* esterno*
1407
1137
1,87
511
54,4
11,2
5,7
GEMINI O 1100
84,0
0,25
200
0,35
529
1511
1241
1,62
296
58,7
4,4
4,2
GEMINI O 1600
81,7
0,42
250
0,93
1197
1579
1299
1,91
728
62,8
5,4
3,6
GEMINI O 2300
81,8
0,55
200
0,83
753
1401
1131
2,04
498
60,8
4,7
3,2
GEMINI O 3400
81,7
0,81
200
1,27
664
1358
1088
1,97
349
49,7
3,1
2,6
Modello
Deformazione cassa
Leakage cassa
Classe filtri
Trasmittanza termica
Ponte termico
GEMINI O 700
D1 (M)
L3 (M)
ePM1
70% F7 (M)
T4 (M)
TB4 (M)
GEMINI O 1100
D1 (M)
L3 (M)
ePM1
70% F7 (M)
T4 (M)
TB4 (M)
GEMINI O 1600
D1 (M)
L3 (M)
70% F7 (M)
T4 (M)
TB4 (M)
GEMINI O 2300
D1 (M)
L3 (M)
ePM1
ePM1
70% F7 (M)
T4 (M)
TB4 (M)
GEMINI O 3400
D1 (M)
L3 (M)
GEMINI O
1100
1600
2300
4300
A2
A2
A2
A2
A2
A2
A2
A1
A2
A2
A2
A2
Leakage
Condizioni di prova
ePM1
70% F7 (M)
T4 (M)
TB4 (M)
700
ESTERNO
Pressione positiva 400 Pa
ESTERNO
Pressione negativa 400 Pa
INTERNO
Differenza di Pressione 250 Pa
A2
A2
A3
Soggetto a modifiche senza obbligo di preavviso