DATI TECNICI

Codice

Modello

CM810N1490

GMV-ND22ZA/A-T

CM810N1480

GMV-ND28ZA/A-T

CM810N1460

GMV-ND36ZA/A-T

CM810N1470

GMV-ND45ZA/A-T

CM810N1450

GMV-ND56ZA/A-T

CM810N1440

GMV-ND63ZA/A-T

CM810N1430

GMV-ND71ZA/A-T

Modello

Unità di

misura

GMV-ND22ZA/A-T

GMV-ND28ZA/A-T

GMV-ND36ZA/A-T

GMV-ND45ZA/A-T

Capacità

Raffreddamento

Riscaldamento

kW

kW

V/Ph/Hz

W

m

3

/h

Pa

dB(A)

Tipo

Tipo

kg/T.CO

2

eq.

mm (inch)

mm (inch)

2,20

2,50

220-240 ~ /1/50

208-230 ~ /1/60

35

250/350/450

10/0~40

25/28/30

Centrifugo

Inverter

R410A

2088

9,52 (3/8")

6,35 (1/4")

Cartella

25

700

615

200

23

2,80

3,20

220-240 ~ /1/50

208-230 ~ /1/60

35

250/350/450

10/0~40

25/28/30

Centrifugo

Inverter

R410A

2088

9,52 (3/8")

6,35 (1/4")

Cartella

25

700

615

200

23

3,60

4,00

220-240 ~ /1/50

208-230 ~ /1/60

43

350/450/550

10/0~40

28/31/33

Centrifugo

Inverter

R410A

2088

12,70 (1/2")

6,35 (1/4")

Cartella

25

700

615

200

23

4,50

5,00

220-240 ~ /1/50

208-230 ~ /1/60

45

400/500/650

15/0~60

28/31/33

Centrifugo

Inverter

R410A

2088

12,7 (1/2")

6,35 (1/4")

Cartella

25

700

615

200

27

Alimentazione elettrica

Potenza assorbita

Portata d'aria (b./m./a.)

Pressione statica esterna

(Di fabbrica / Range di regolazione)

Livello pressione sonora (b./m./a.)*

Ventilatore

Motore Ventilatore

Tipo di refrigerante

GWP refrigerante

Diametro

tubazioni

Scarico condensa

Dimensioni nette

Peso netto

Tubo Gas

Tubo Liquido

Tipo collegamento

Diametro

esterno

Larghezza

Profondità

Altezza

mm

mm

mm

mm

kg

I dati tecnici riportati fanno riferimento alla normativa europea EN14511.

* Livello di pressione sonora misurato in camera anecoica alle seguenti condizioni: 1 m dalla superficie del coperchio di servizio dell’unità e 1,5 metri dal livello del pavimento.

165