GMV6 HR

DATI TECNICI COMBINAZIONI

Taglia

HP

52

54

56

58

60

Capacità raffreddamento

nominale*

Capacità riscaldamento

nominale*

Range min.-max. potenza unità

interne

kW

145,5

kW

163,5

%

50-135

12+20+20

14+20+20

152

171

50-135

13500 + 16500 +

16500

0-110

380-415

3N~50/60

9,26 + 16,03 + 16,03

9,14 + 14,92 + 14,92

21 + 26,85 + 26,85

37,5/40 + 48/50 +

48/50

R410A

2088

16+20+20

157

176

50-135

15400 + 16500 +

16500

0-110

380-415

3N~50/60

11,55 + 16,03 + 16,03

11,27 + 14,92 + 14,92

22 + 26,85 + 26,85

39,3/40 + 48/50 +

48/50

R410A

2088

18+20+20

162,4

182,5

50-135

16000 + 16500 +

16500

0-110

380-415

3N~50/60

13,01 + 16,03 + 16,03

12,94 + 14,92 + 14,92

26,3 + 26,85 + 26,85

20+20+20

168

189

50-135

16500 + 16500 +

16500

0-110

380-415

3N~50/60

16,03 + 16,03 + 16,03

14,92 + 14,92 + 14,92

26,85 + 26,85 + 26,85

Combinazioni di unità esterne

GMV-VQ335WM/C-X +

GMV-VQ560WM/C-X +

GMV-VQ560WM/C-X

GMV-VQ400WM/C-X +

GMV-VQ560WM/C-X +

GMV-VQ560WM/C-X

GMV-VQ450WM/C-X +

GMV-VQ560WM/C-X +

GMV-VQ560WM/C-X

GMV-VQ504WM/C-X +

GMV-VQ560WM/C-X +

GMV-VQ560WM/C-X

GMV-VQ560WM/C-X +

GMV-VQ560WM/C-X +

GMV-VQ560WM/C-X

Portata d’aria

m

3

/h

11100 + 16500 +

16500

Pressione statica esterna

dell'unità

Alimentazione elettrica

Potenza assorbita in

raffreddamento

Potenza nominale assorbita in

riscaldamento

Potenza assorbita massima

Corrente assorbita massima

Tipo di refrigerante

GWP refrigerante

N° massimo unità interne

collegabili

Lunghezza massima delle

tubazioni

Distanza massima tra esterna

e ultima interna

Dislivello massimo (tra unità

interne)

Dislivello massimo

(unità esterna sopra/sotto)

Raffreddamento

Limiti di

Riscaldamento

funzionamento

Pa

0-110

V

380~415

Hz

3N~50/60

kW

8,55 + 16,03 + 16,03

kW

7,8 + 14,92 + 14,92

kW

13,5 + 26,85 + 26,85

A

24,1/25 + 48/50 +

48/50

R410A

kgCO

2

eq.

2088

47/50 + 48/50 + 48/50 48/50 + 48/50 + 48/50

R410A

R410A

2088

2088

Carica di refrigerante standard

kg/T.

CO

2

eq.

9,60/20,045 +

12,80/26,726 +

12,80/26,726

11,10/23,177 +

12,80/26,726 +

12,80/26,726

11,60/24,221 +

12,80/26,726 +

12,80/26,726

12,80/26,726 +

12,80/26,726 +

12,80/26,726

12,80/26,726 +

12,80/26,726 +

12,80/26,726

Diametro

tubazioni

Tubo del Gas

(alta pressione)

mm

1-1/2

1-1/2

1-1/2

1-1/2

1-1/2

Tubo del Gas

(bassa

pressione)

mm

1-5/8

1-5/8

1-5/8

1-5/8

1-5/8

Tubo del

Liquido

mm

3/4

3/4

3/4

3/4

3/4

85

89

92

95

99

m

1000

m

200

1000

1000

1000

1000

200

200

200

200

m

30

30

30

30

30

m

100/110

°C

-10~55

°C

-25~24

100/110

100/110

-10~55

-10~55

-25~24

-25~24

-20~35

-20~35

100/110

100/110

-10~55

-10~55

-25~24

-25~24

-20~35

-20~35

54

ACS

-20~35

• Condizioni di prova della capacità di raffreddamento nominale: unità interna 27 °C B.S./19 °C B.U. - unità esterna 35 °C B.S.; lunghezza tubo di

collegamento: 5 m, senza dislivello tra le unità

• Condizioni di prova della capacità di riscaldamento nominale: unità interna 20 °C B.S. - unit

à esterna 7 °C B.S./6 °C B.U.; lunghezza tubo di collegamento:

5 m, senza dislivello tra le unità

• La somma delle capacità delle unità interne collegate deve essere compresa nell’intervallo (50%~135%) della capacità delle unità esterne. I parametri

pertinenti possono essere corretti facendo riferimento alla tabella di correzione della capacità delle unità.

• I parametri riportati sopra sono testati in base alla lunghezza del tubo di collegamento standard. Nel progetto effettivo, i parametri devono essere corretti

facendo riferimento alla lunghezza effettiva delle tubazioni.