• Quanti profili possono essere alimentati dalla stessa fonte di

alimentazione?

Il limite è dato dalla la potenza. Usando la fonte di alimentazione di 120W

bisogna adeguare il numero di apparecchi a questa potenza massima.

• Quanti profili possono essere collegati a un solo giunto?

Allo stesso giunto possono essere collegati massimo 8 profili.

• How many profiles can I feed up with the same driver?

Power is the limit. When using the 120W driver model, the number of

luminaires must be adjusted to that maximum consumption.

• How many profiles can I connect to one single joint?

It is possible to connect up to 8 profiles to the same joint.

DIVERSION — FAQ

• Quanti profili possono essere alimentati da un solo giunto di

alimentazione?

Il massimo sono 8, uno ogni 45o, e il limite è dato dalla potenza che deve

essere inferiore a 120W.

- Esempio 1: usando i profili di 1m e di illuminazione diretta (DOWN).

Potenza Modulo luce = 13,5W.

120W/13,5W = 8,88 moduli, arrotondando al numero intero per difetto

abbiamo un massimo di 8 moduli.

Quindi il giunto potrà essere completato con un massimo di 8 moduli lineari di

luce senza faretti.

- Esempio 2: usando i profili di 2,5m con emissione diretta e indiretta

(Up&Down) con due faretti Atom 120.

Potenza Modulo luce + 2 faretti = 54,5W + 2X8W = 70,5W. 120W/70,5W = 1,7

moduli, arrotondando al numero intero per difetto abbiamo un massimo di 1

modulo.

Quindi il giunto potrà essere completato con un solo modulo lineare di

luce con due faretti. Per aggiungere altri elementi allo stesso giunto, questi

dovranno essere alimentati da un altro giunto nell’estremo opposto.

È fondamentale configurare gli interruttori situati agli estremi di ogni profilo

per evitare di attivare/disattivare varie fonti di alimentazione, cosa che

provocherebbe un cattivo funzionamento del sistema.

• How many profiles can I feed up with one single feeding joint?

The maximum quantity is 8 pieces, one every 45°. The limit is represented by

their total power consumption which has to be less than 120W.

- Example 1; when using 1m profiles with direct light emission (DOWN).

Lighting module power consumption = 13,5W.

120W/13,5W = 8,88 lighting modules, which means 8 modules maximum.

The joint could therefore feature up to 8 light modules single emission without

spots.

- Example 2; when using 2,5m profiles featuring direct/indirect light emission

(Up&Down) with 2 Atom 120 spots.

Lighting module power consumption including 2 spots = 54,5W + 2x8W =

70,5W.

120W/70,5W = 1,7 modules, which means 1 module maximum.

It is therefore possible to complete a joint attaching only one lighting module

Up&Down equipped with two spots. In order to add more elements to the

same joint, these will need to be fed by another dedicated joint located on the

opposite side of the profile.

Please make sure to set the integrated switches located at the end of each

profile. This will avoid switching multiple power supplies, which would cause

the entire system to malfunction.

• Posso controllare ogni apparecchio individualmente?

No, il sistema è controllato simultaneamente (broadcast). L’illuminazione

diretta e indiretta non possono essere separate per essere controllate in modo

indipendente.

I moduli con illuminazione indiretta sono dotati di un commutatore per ridurre

la potenza massima al 50%, fissando questa potenza massima senza incidere

sulle opzioni di regolazione DALI, 1-10V o Casambi.

• Can I control each luminaire individually?

No, the entire system is controlled simultaneously (broadcast). Direct and

indirect lighting cannot be separated for independent control either.

Modules with indirect illumination are equipped with a switch to reduce the

maximum power of 50%, establishing it as the maximum without affecting the

DALI, 1-10V or Casambi dimming options.

UP LIGHT

50%

50%

100%

100%