CALDAIE AD ACQUA SURRISCALDATA | SUPERHEATED WATER BOILERS

PREXTHERM T3G N ASL

DIMENSIONI / DIMENSIONS

LEGENDA

1 Caldaia

2 Porta

3 Camera fumo

4 Quadro elettrico

Dimensioni / Dimensions

Ritorno / Return

Sicurezze / Safety

Scarico / Drain

Uscita fumo / Flue outlet

Peso a secco / Dry weight

KEY

1 Boiler

2 Door

3 Smokebox

4 Electrical panel

B

C

D

T2

T3

T4

T5

mm

mm

mm

DN

DN

DN

Ø mm

2780

2780

6050

6530

1105

1105

250

250

65

80

40

40

700

700

13800

14700

6522

7609

12500

13750

120

150

6,1

8,4

9787

11418

6

6

3040

3040

3040

6990

7290

7290

1220

1220

1220

250

250

300

80

80

100

40

40

40

800

900

900

17500

19700

23000

8697

9783

10870

17150

18600

21600

210

230

180

8,2

8,5

8,7

13049

14680

16311

6

6

6

3200

3700

7860

8640

1240

1382

300

350

80

100

40

65

900

1000

26000

33000

13044

16305

23000

31600

230

250

8,9

11,5

17950

23500

6

6

ACCESSORI A CORREDO

- 1 quadro elettrico completo di:

termostato limite, termostato

sicurezza, termometro

- 1 o 2 valvole di sicurezza a leva

- 1 pressostato di sicurezza RT

- 1 manometro tipo Bourdon con rubinetto a tre

vie

- 1 valvola di scarico a leva con valvola di

intercettazione

PREXTHERM T 3G N ASL

6000

7000

8000

9000

10000

12000

15000

**

ACCESSORIES SUPPLIED

- 1 electrical panel complete with:

limit thermostat, safety thermostat,

thermometer

- 1 or 2 lever-operated safety valves

- 1 RT safety pressure switch

- 1 Bourdon pressure gauge with three-way valve

- 1 lever-operated valve with on-off valve

A

mm

2500

2500

2710

2710

2710

2860

3260

E

mm

2140

2140

2140

2140

2140

2860

2800

ATTACCHI / FITTINGS

Mandata / Flow

T1

DN

250

250

250

250

300

300

350

DATI TECNICI / TECHNICAL DATA

Potenza focolare / Heat input

kW

Capacità totale caldaia / Boiler total capacity

dm

3

standard 6 bar kg

PREXTHERM T 3G N ASL

6000

7000

8000

9000

10000

12000

15000

**

Potenza utile / Heat output

kW

6000

7000

8000

9000

10000

12000

15000

Perdite di carico lato acqua

Loss pressure water side

Perdite di carico lato fumi / Press. drop flue gas side

mbar

Portata fumi* / Flue gas flow-rate*

kg/h

Pressione max esercizio** / Max working pressure**

bar

∆t 15°C

mbar

* Combustibile gasolio: CO2 = 13% - combustibile gas: CO2 = 10% * Oil fuel: CO2 = 13% - Gas fuel: CO2 = 10%

** Dimensioni superiori: verifica fattibilità su richiesta ** On request we evaluate the feasibility for higher powers

80