R32

GAMMA

EUROVENT

La certificazione Eurovent verifica le prestazioni dei sistemi di riscaldamento

e

raffrescamento secondo gli standard europei, fornendo dati sull’efficienza de

i

prodotti in piena trasparenza, a vantaggio di clienti e professionisti

.

HP

4 HP

5 HP

6 HP

8 HP

10 H

P

Unità esterna

U-4LZ2E5

U-4LZ2E8

U-5LZ2E5

U-5LZ2E8

U-6LZ2E5

U-6LZ2E8

U-8LZ2E8

U-10LZ2E8

Abbinamento con unità interne

S-**MU2: S-**MU2E5

C

S-**MF3: S-**MF3E5

D

Dati tecnici VRF certificati Eurovent: Serie Mini ECOi LZ2 da 4 a 10 HP - R32

2

x

S-36MF3,

2

x

S-45MF

3

2

x

S-36MU2

,

2

x

S-45MU

2

2

x

S-36MF3,

2

x

S-45MF

3

4x

S-56MU2

4x

S-56MF3

4x

S-73MU

2

4x

S-73MF

3

2

x

S-60MU2

2

x

S-60MU

2

2x

S-36MU2,

2x

S-45MU

2

Pc out 1) kW

12,1

12,1

12,1

12,1

14,0

14,0

14,0

14,0

15,5

15,5

15,5

15,5

22,4

19,0

28,0

23,

8

Raffresc.

Pec out 2) kW

3,0

3,6

3,0

3,6

3,7

4,5

3,7

4,5

4,4

5,2

4,4

5,2

6,8

6,8

9,7

9,

5

EER out

4,1

3,4

4,1

3,4

3,8

3,1

3,8

3,1

3,5

3,0

3,5

3,0

3,3

2,8

2,9

2,

5

Raffresc. stagionale

ηs,c

%

337,0

270,6

337,0

270,6

321,8

267,4

321,8

267,4

305,4

258,2

305,4

258,2

299,4

228,6

280,2

225,8

Raffresc. PL

Condizione B

PcB

kW

8,9

8,9

8,9

8,9

10,3

10,3

10,3

10,3

11,4

11,4

11,4

11,4

16,5

14,0

20,6

17,

5

Raffresc. P

L

Condizione C

PcC

kW

5,7

5,7

5,7

5,7

6,6

6,6

6,6

6,6

7,3

7,3

7,3

7,3

10,6

9,0

13,2

11,2

EERC

11,3

8,8

11,3

8,8

10,8

9,0

10,8

9,0

10,2

8,8

10,2

8,8

9,6

7,0

8,7

6,

7

Raffresc. PL

Condizione

D

PcD

kW

5,4

5,4

5,4

5,4

5,6

5,4

5,6

5,4

5,8

5,4

5,8

5,4

9,0

7,1

9,5

8,

0

Pdesign kW

10,0

10,0

10,0

10,0

11,2

11,2

11,2

11,2

11,6

11,6

11,6

11,6

17,5

16,2

19,6

18,2

Riscald. stagional

e

ηs,h

%

199,0

155,8

199,0

155,8

181,4

151,0

181,4

151,0

180,6

146,6

180,6

146,6

180,6

147,4

181,0

151,4

Riscald. PL

Condizione A

PhA

kW

8,8

8,8

8,8

8,8

9,9

9,9

9,9

9,9

10,3

10,3

10,3

10,3

15,4

14,3

17,3

16,

1

T bivalente

SEER

EERB

EERD

SCOP

COPA

COPB

COPC

COPD

3x

S-28MF3,

1x

S-36MF3

3x

4x

4x

4

x

4

x

S-28MF3,

S-36MU

2

S-36MF3

S-36MU

2

S-36MF3

1x

S-36MF3

8,5

6,8

8,5

6,8

8,1

6,8

8,1

6,8

7,7

6,5

7,7

6,5

7,6

5,8

7,1

5,

7

6,5

5,2

6,5

5,2

5,9

4,9

5,9

4,9

5,4

4,7

5,4

4,7

5,2

4,2

4,6

4,

0

15,6

12,3

15,6

12,3

15,2

12,1

15,2

12,1

15,0

11,0

15,0

11,0

16,6

11,5

18,0

13,

1

5,1

4,0

5,1

4,0

4,6

3,9

4,6

3,9

4,6

3,7

4,6

3,7

4,6

3,8

4,6

3,

9

3,1

2,5

3,1

2,5

2,9

2,4

2,9

2,4

2,9

2,3

2,9

2,3

2,9

2,4

2,8

2,

3

4,8

3,6

4,8

3,6

4,1

3,4

4,1

3,4

4,1

3,3

4,1

3,3

4,2

3,5

4,2

3,

6

7,2

6,1

7,2

6,1

7,2

6,2

7,2

6,2

7,1

6,1

7,1

6,1

6,9

5,4

7,1

5,

8

9,1

7,4

9,1

7,4

9,3

7,3

9,3

7,3

9,3

7,3

9,3

7,3

8,7

6,8

9,2

7,

2

W

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

18,0

18,0

18,0

18,

0

W

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

18,0

18,0

18,0

18,

0

W

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

18,0

18,0

18,0

18,0

W

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

14,0

18,0

18,0

18,0

18,0

W

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

26,0

26,0

26,0

26,0

W

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

26,0

26,0

26,0

26,

0

W

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

26,0

26,0

26,0

26,

0

W

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

18,0

26,0

26,0

26,0

26,0

Livello potenza sonora / in

riscaldamento

dB(A) 69 / 72

—

69 / 72

—

70 / 74

—

70 / 74

—

72 / 75

—

72 / 75

—

72 / 74

—

74 / 75

—

Riscald. PL

Condizione B

PhB

kW

5,4

5,4

5,4

5,4

6,0

6,0

6,0

6,0

6,2

6,2

6,2

6,2

9,4

8,7

10,5

9,

8

Riscald. P

L

Condizione C

PhC

kW

3,5

3,5

3,5

3,5

3,9

3,9

3,9

3,9

4,0

4,0

4,0

4,0

6,2

5,6

6,7

6,

3

Riscald. PL

Condizione D

PhD

kW

4,0

3,5

4,0

3,5

4,0

3,5

4,0

3,5

4,0

3,5

4,0

3,5

6,7

6,0

6,9

6,

2

Tbiv

°C

-10

-7

-10

-7

-7

-7

-7

-7

-7

-7

-7

-7

-7

-7

-7

-7

PhTbiv

kW

10,0

8,8

10,0

8,8

9,9

9,9

9,9

9,9

10,3

10,3

10,3

10,3

15,4

14,3

17,3

16,1

COPTbiv

2,5

2,5

2,5

2,5

2,9

2,4

2,9

2,4

2,9

2,4

2,9

2,4

2,9

2,4

2,8

2,

3

Psbc

Psbh

Poffc

Poffh

Ptoc

Ptoh

Pckc

Pckh

Dati tecnici VRF certificati Eurovent: Serie ECOi EX MZ1 a 2 tubi da 8 a 12 HP -· R32

HP

8 HP

10 HP

12 H

P

Unità esterna

U-8MZ1E8

U-8MZ1E8

U-10MZ1E8

U-10MZ1E8

U-12MZ1E8

U-12MZ1E8

Abbinamento con unità interne

S-**MU2: S-**MU2E5

C

S-**MF3: S-**MF3E5

D

4x S-56MU2

4x S-56MF3

4x S-73MU2

4x S-73MF3

6x S-56MU2

6x S-56MF

3

Pc out 1) kW

22,40

18,10

28,00

22,70

33,50

27,20

Raffresc.

Pec out 2) kW

6,78

6,70

8,00

8,11

11,17

11,33

EER out

3,30

2,70

3,50

2,80

3,00

2,40

SEER

7,27

5,20

7,82

5,62

7,37

5,30

Raffresc. stagional

e

ηs,c

%

288,00

205,10

310,10

221,80

292,10

209,20

Raffresc. PL

Condizione B

PcB

kW

16,50

13,80

20,60

17,20

24,70

20,70

EERB

5,10

3,90

5,30

4,10

4,80

3,7

0

Raffresc. PL

Condizione C

PcC

kW

10,60

8,60

13,30

10,80

15,90

13,00

EERC

9,10

6,10

9,60

6,50

8,90

6,0

0

Raffresc. PL

Condizione D

PcD

kW

9,30

8,00

9,80

8,40

10,10

8,7

0

EERD

16,30

10,50

18,40

11,80

19,60

12,70

Pdesign kW

16,30

13,20

20,50

16,50

24,40

19,80

Riscald. stagional

e

SCOP

4,35

3,57

4,38

3,57

4,33

3,6

1

ηs,h

%

171,00

140,10

172,40

139,80

170,30

141,60

Riscald. PL

Condizione A

PhA

kW

14,40

13,20

18,10

16,50

21,60

19,80

COPA

2,80

2,30

2,70

2,30

2,40

2,1

0

Riscald. PL

Condizione B

PhB

kW

8,70

7,90

11,00

9,90

13,10

11,90

COPB

4,10

3,50

4,00

3,30

4,00

3,4

0

Riscald. PL

Condizione C

PhC

kW

5,90

5,40

7,10

6,50

8,40

7,8

0

COPC

6,10

5,00

6,60

5,40

7,00

5,80

Riscald. PL

Condizione D

PhD

kW

6,90

6,90

7,40

7,40

6,80

6,80

COPD

7,50

6,80

8,50

7,70

8,20

7,50

Tbiv

°C

-10

-7

-10

-7

-10

-

7

T bivalente

PhTbiv

kW

16,30

13,20

20,50

16,50

24,40

19,80

COPTbiv

2,40

2,30

2,40

2,30

2,10

2,10

Psbc

W

15,00

15,00

15,00

15,00

15,00

15,00

Psbh

W

15,00

15,00

15,00

15,00

15,00

15,00

Poffc

W

1,00

1,00

1,00

1,00

1,00

1,00

Poffh

W

34,00

34,00

34,00

34,00

34,00

34,00

Ptoc

W

24,00

24,00

24,00

24,00

24,00

24,00

Ptoh

W

23,00

23,00

23,00

23,00

23,00

23,00

Pckc

W

23,00

23,00

23,00

23,00

23,00

23,00

Pckh

W

37,00

37,00

37,00

37,00

37,00

37,00

Livello potenza sonora / in

riscaldamento

dB(A)

75 / 75

75 / 75

77 / 77

77 / 77

81 / 84

81 / 84

1) Pc out= Capacità. 2) Pec out= Potenza in ingresso. *Per ciascuna condizione di prova, consultare il sito web ufficiale (https://www.eurovent-certification.com/en).