HP
Unità esterna
U
n
ità estern
a
50 HP
52 HP
54 HP
56 HP
58 HP
60 HP
62 HP
64 HP
U-14ME2E8
U
-
14ME2E8 U-16ME2E8
U
-
16ME2E8 U-14ME2E8
U
-
14ME2E8 U-16ME2E8
U
-
16ME2E8 U-18ME2E8
U
-
18ME2E8 U-20ME2E8
U
-
20ME2E8 U-14ME2E8
U
-
14ME2E8 U-16ME2E8
U
-
16ME2E8
U-16ME2E8
U
-
16ME2E8 U-16ME2E8
U
-
16ME2E8 U-20ME2E8
U
-
20ME2E8 U-20ME2E8
U
-
20ME2E8 U-20ME2E8
U
-
20ME2E8 U-20ME2E8
U
-
20ME2E8 U-16ME2E8
U
-
16ME2E8 U-16ME2E8
U
-
16ME2E8
U-20ME2E8
U
-
20ME2E8 U-20ME2E8
U
-
20ME2E8 U-20ME2E8
U
-
20ME2E8 U-20ME2E8
U
-
20ME2E8 U-20ME2E8
U
-
20ME2E8 U-20ME2E8
U
-
20ME2E8 U-16ME2E8
U
-
16ME2E8 U-16ME2E8
U
-
16ME2E8
Tensione
V
380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 -
U-16ME2E8
U
-
16ME2E8 U-16ME2E8
U
-
16ME2E8
400 - 415 380 - 400 - 415 380 - 400 - 415
Alimentazion
e
Fase
Trifase
Trifase
Trifase
Trifase
Trifase
Trifase
Trifase
Trifas
e
Frequenza
Hz
50
50
50
50
50
50
50
5
0
Capacità di raffresc.
kW
140,0
145,0
151,0
156,0
162,0
168,0
174,0
180,0
EER 1)
W/W
3,55
3,46
3,49
3,41
3,40
3,35
3,60
3,52
SEER 2)
6,96
6,72
7,16
6,92
7,30
7,16
6,68
6,5
5
Corrente
A
64,4
0 - 61,10 - 58,90 68,50 - 65,00 - 62,70 70,00 - 66,50 - 64,10 74,00 - 70,30 - 67,80 76,90 - 73,10 - 70,40 80,10 - 76,10 - 73,40 79,80 - 75,80 - 73,00 84,60 - 80,30 - 77,40
Potenza d'ingresso
kW
39,40
41,90
43,30
45,80
47,60
50,10
48,30
51,20
Capacità di riscald.
kW
155,0
160,0
169,0
175,0
182,0
189,0
195,0
201,0
COP 1)
W/W
4,29
4,27
4,11
4,08
4,06
3,94
4,45
4,42
SCOP 2)
4,08
4,05
4,13
4,07
4,13
4,13
4,11
4,0
9
Corrente
A
59,60 - 56,60 - 54,60 61,90 - 58,80 - 56,70 67,10 - 63,80 - 61,50 70,10 - 66,60 - 64,20 73,20 - 69,50 - 67,00 77,60 - 73,70 - 71,00 73,10 - 69,50 - 67,00 76,00 - 72,20 - 69,60
Potenza d'ingresso
kW
36,10
37,50
41,10
42,90
44,80
48,00
43,80
45,50
Corrente di avviamento
A
6,00
6,00
6,00
6,00
6,00
6,00
8,00
8,00
Pressione statica esterna (max)
Pa
80
80
80
80
80
80
80
80
Portata d'aria
m³/min
869
869
1 042
1 042
1 215
1 215
928
928
Potenza sonora
Modalità normale
dB(A)
86,5
86,5
86,0
86,5
85,5
86,0
88,0
88,0
Dimensioni
/
x 1.000 / 1.00
5
1.842 x 4.020
x 1.000 / 1.005
1.842 x 4.38
0
x 1.000 / 1.065
1.842 x 4.380
x 1.000 / 1.065
1.842 x 4.740
x 1.000 / 1.125
1.842 x 4.74
0
x 1.000 / 1.12
5
1.842 x 4.900
x 1.000 / 1.260
1.842 x 4.90
0
x 1.000 / 1.260
7/8 (22,22
)
3/4 (19,05)
/
7/8 (22,22)
3/4 (19,05) /
7/8 (22,22)
3/4 (19,05)
/
7/8 (22,22
)
3/4 (19,05)
/
7/8 (22,22)
3/4 (19,05) /
7/8 (22,22)
3/4 (19,05)
/
7/8 (22,22
)
3/4 (19,05) /
7/8 (22,22
)
Diametro dell
e
tubazioni 3)
1-5/8 (41,28
)
1-1/2 (38,10)
/
1-5/8 (41,28
)
1-1/2 (38,10) /
1-5/8 (41,28
)
1-1/2 (38,10) /
1-5/8 (41,28
)
1-1/2 (38,10)
/
1-5/8 (41,28
)
1-1/2 (38,10) /
1-5/8 (41,28
)
1-5/8 (41,28) /
1-3/4 (44,45
)
1-5/8 (41,28) /
1-3/4 (44,45
)
Bilanciamento
Pollici (mm)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35
)
54,4968
26,10 /
54,4968
27,30 /
57,0024
27,30 /
69,3216
33,20 /
69,3216
Rapporto di capacità interno / estern
o
~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200)
Intervallo d
i
funzionament
o
Raffresc. Min ~ Max °C
-1
0
Riscald. Min ~ Max °C
-2
5
~
~
+52
-10
+18
-25
~
~
+52
-10
+18
-25
~ +52
-1
0
~
~ +52
-10 ~ +52
-1
0 ~ +52
-1
0 ~ +52
-1
0 ~ +52
+18
-2
5 ~ +18
-25 ~ +18
-2
5 ~ +18
-2
5 ~ +18
-2
5 ~ +18
HP
Unità esterna
66 HP
68 HP
70 HP
72 HP
74 HP
76 HP
78 HP
80 HP
U-10ME2E8 U-12ME2E8 U-10ME2E8 U-16ME2E8 U-16ME2E8 U-16ME2E8 U-18ME2E8 U-20ME2E8
U-16ME2E8 U-16ME2E8 U-20ME2E8 U-16ME2E8 U-18ME2E8 U-20ME2E8 U-20ME2E8 U-20ME2E
8
U-20ME2E8 U-20ME2E8 U-20ME2E8 U-20ME2E8 U-20ME2E8 U-20ME2E8 U-20ME2E8 U-20ME2E8
Alimentazion
e
U-20ME2E8 U-20ME2E8 U-20ME2E8 U-20ME2E8 U-20ME2E8 U-20ME2E8 U-20ME2E8 U-20ME2E
8
Tensione
V
38
0 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
Fase
Trifase
Trifase
Trifase
Trifase
Trifase
Trifase
Trifase
Trifas
e
Frequenza
Hz
50
50
50
50
50
50
50
50
Capacità di raffresc.
kW
185,0
190,0
196,0
202,0
208,0
213,0
219,0
224,0
EER 1)
W/W
3,52
3,49
3,47
3,42
3,42
3,39
3,38
3,35
SEER 2)
6,92
6,91
7,09
6,86
7,03
7,01
7,18
7,1
6
Corrente
A
85,00 - 80,80 - 77,80 88,10 - 83,70 - 80,70 91,30 - 86,80 - 83,60 95,40 - 90,60 - 87,30 98,30 - 93,40 - 90,00 101,70 - 96,60 - 93,10 103,50 - 98,30 - 94,70 106,80 - 101,50 - 97,80
Potenza d'ingresso
kW
52,60
54,50
56,50
59,00
60,80
62,90
64,70
66,8
0
Capacità di riscald.
kW
207,0
213,0
219,0
226,0
233,0
239,0
245,0
252,0
COP 1)
W/W
4,16
4,18
4,05
4,14
4,12
4,03
4,03
3,9
4
SCOP 2)
4,11
4,17
4,13
4,06
4,12
4,07
4,13
4,13
Corrente
A
81,2
0 - 77,10 - 74,30 83,30 - 79,20 - 76,30 87,40 - 83,10 - 80,10 89,20 - 84,70 - 81,70 92,30 - 87,70 - 84,50 96,90 - 92,00 - 88,70 98,30 - 93,40 - 90,00 103,40 - 98,30 - 94,70
Potenza d'ingresso
kW
49,70
51,00
54,10
54,60
56,50
59,30
60,80
64,00
Corrente di avviamento
A
7,00
7,00
7,00
8,00
8,00
8,00
8,00
8,00
Pressione statica esterna (max)
Pa
80
80
80
80
80
80
80
80
Portata d'aria
m³/min
1.266
1.274
1.439
1.274
1.447
1.447
1.620
1.620
Potenza sonora
Modalità normale
dB(A)
87,0
87,5
86,5
87,5
87,5
87,5
87,0
87,0
Dimensioni
/
1.000 / 1.27
5
1.842 x 5.620 x
1.000 / 1.33
5
1.842 x 5.570
x
1.000 / 1.33
5
1.842 x 5.620
x
1.000 / 1.380
1.842 x 5.980 x
1.000 / 1.44
0
1.842 x 5.980
x
1.000 / 1.44
0
1.842 x 6.340 x
1.000 / 1.500
1.842 x 6.340 x
1.000 / 1.500
7/8 (22,22
)
7/8 (22,22)
/
1 (25,04)
7/8 (22,22)
/
1 (25,04)
7/8 (22,22) /
1 (25,04
)
7/8 (22,22)
/
1 (25,04)
7/8 (22,22)
/
1 (25,04
)
7/8 (22,22) /
1 (25,04)
7/8 (22,22) /
1 (25,04)
Diametro dell
e
tubazioni 3)
1-3/4 (44,45
)
1-5/8 (41,28)
/
1-3/4 (44,45
)
1-5/8 (41,28)
/
1-3/4 (44,45
)
1-3/4 (44,45) /
2 (50,80
)
1-3/4 (44,45) /
2 (50,80)
1-3/4 (44,45)
/
2 (50,80
)
1-3/4 (44,45) /
2 (50,80)
1-3/4 (44,45) /
2 (50,80)
Bilanciamento
Pollici (mm)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
68,6952
35,60 /
68,6952
36,80 /
76,8384
36,80 /
Rapporto di capacità interno / esterno
~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200)
Intervallo di
funzionamento
Raffresc. Min ~ Max °C
-10
Riscald. Min ~ Max °C
-25
~
~
+52
-1
0
+18
-2
5
~
~
+52
-10
+18
-25
~
~
+52
-1
0
+18
-2
5
~
~
+52
-1
0
+18
-2
5
~
~
+52
-10
+18
-25
~
~
+52
-1
0
+18
-2
5
~
~
+52
-1
0
+18
-2
5
~
~
+5
2
+18
1) Il calcolo di EER e COP si basa sulla norma EN 14511. 2) Il calcolo di SEER / SCOP si basa sui valori “η” di efficienza stagionale di raffrescamento/riscaldamento degli ambienti del REGOLAMENTO (UE)
2016/2281 DELLA COMMISSIONE. SEER, SCOP = (η + correzione) × PEF. 3) Diametro delle tubazioni inferiore a 90 m per l'unità interna finale / superiore a 90 m per l'unità interna finale (se la lunghezza
equivalente delle tubazioni supera i 90 m, aumentare di 1 le dimensioni dei tubi principali per i tubi del gas e del liquido). 4) Se sono soddisfatte le seguenti condizioni, l'intervallo effettivo è superiore al 130%
e
inferiore al 200%: A. Rispettare il limite di unità interne collegabili. B. Il limite inferiore di funzionamento per la temperatura esterna di riscaldamento è limitato a -10 °C B.U. (standard -25 °C B.U.). C. I
l
funzionamento simultaneo è limitato a meno del 130% delle unità interne collegabili.
Condizioni nominali: Raffrescamento interno 27 °C B.S. / 19 °C B.U. Raffrescamento esterno 35 °C B.S. / 24 °C B.U. Riscaldamento interno 20 °C B.S. Riscaldamento esterno 7 °C B.S. / 6 °C B.U. (B.S.: Bulbo Secco; B.U.: Bulbo Umido).
Le specifiche sono soggette a modifiche senza preavviso. Per informazioni dettagliate su ErP / Etichette energetiche, visitate i nostri siti web www.aircon.panasonic.eu o www.ptc.panasonic.eu
.
67