Unità interna
LPG350D
LPG500D
LPG700D
LPG850D
LPG1000D
LPG1200D
LPG1400D
Unità esterna
LPG350
LPG500
LPG700
LPG850
LPG1000
LPG1200
LPG1400
Prestazioni in raffrescamento nominali
Potenza frigorifera (1)
kW
3,50
5,30
7,10
8,50
10,50
12,10
13,40
Potenza assorbita a freddo (1)
kW
1,03
1,51
1,92
2,50
3,00
3,58
4,50
EER (2)
W/W
3,40
3,51
3,70
3,40
3,50
3,38
2,98
Umidità asportata
l/h
1,0
1,7
2,4
2,8
3,3
3,7
3,9
Prestazioni in raffrescamento minime e massime
Potenza frigorifera
min / max
kW
0,90/4,00
1,60/5,80
2,40/7,60
2,90/9,00
3,20/11,00
3,60/13,10
4,00/14,20
Potenza assorbita a freddo
min / max
kW
0,20/1,30
0,30/1,80
0,50/2,60
0,75/3,30
0,90/4,00
1,10/5,30
1,35/5,60
Efficienza stagionale
SEER
W/W
6,50
6,30
6,60
6,40
6,40
6,10
6,10
Classe efficienza energetica (3)
A++
A++
A++
A++
A++
-
-
Pdesignc
kW
3,5
5,3
7,1
8,5
10,5
-
-
Consumo elettrico annuo
kWh/annum
189
294
377
465
574
-
-
Prestazioni in riscaldamento nominali
Potenza termica (4)
kW
4,00
5,60
8,00
8,80
11,50
13,50
15,50
Potenza assorbita a caldo (4)
kW
1,00
1,42
2,00
2,25
2,80
3,70
4,50
COP (2)
W/W
4,00
3,94
4,00
3,91
4,11
3,65
3,44
Prestazioni in riscaldamento minime e massime
Potenza termica
min / max
kW
0,90/4,50
1,60/6,10
2,20/8,60
2,50/9,50
3,00/12,50
3,60/14,50
3,90/16,00
Potenza assorbita a caldo
min / max
kW
0,20/1,30
0,30/1,85
0,50/2,60
0,75/3,30
0,90/4,00
0,90/4,00
1,35/5,60
Efficienza stagionale (clima temperato)
SCOP
4,00
4,00
4,10
4,10
4,20
4,10
4,00
Classe efficienza energetica (3)
A+
A+
A+
A+
A+
-
-
Pdesignh
kW
3,00
3,90
4,70
6,00
7,00
-
-
Consumo elettrico annuo
kWh/annum
1050
1365
1605
2049
2333
-
-
Dati elettrici
Potenza nominale assorbita (5)
kW
1,3
1,9
2,8
3,3
4,7
5,3
5,6
Corrente nominale assorbita (5)
A
6,0
9,5
14,0
15,0
21,0
23,0
25,0
Ventilatore
Tipo di ventilatore
Tipo
Centrifugo inverter
Portata d’aria
turbo/max/med/
min
m
3
/h
600/550/500/400
900/800/700/600
1100/1000/900/800 1400/1300/1100/1000 1700/1600/1400/1200 2000/1800/1600/1400 2300/2100/1800/1500
Pressione statica utile
nominale/min/
Pa
25/0/80
25/0/80
26/0/160
37/0/160
37/0/150
50/0/155
50/0/200
max
Pressione sonora (6)
turbo/max/med/
dB(A)
35/33/32/30
36/35/33/31
37/35/33/31
43/41/39/37
39/38/37/36
43/42/41/40
43/42/40/38
min
Tubazioni frigorifere
Diametro attacchi frigoriferi
mm (inch)
6,35 (1/4”)
6,35 (1/4”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
liquido
Diametro attacchi frigoriferi gas
mm (inch)
9,52 (3/8”)
12,7 (1/2”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
Diametro scarico condensa
mm
26,0
26,0
26,0
26,0
26,0
26,0
26,0
Alimentazione
220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz 220-240V ~ 50Hz
Dimensioni
mm
710X450X200
1000X450X200
900X655X260
900X655X260
1340X655X260 1340X655X260 1400X700X300
(1) Raffrescamento (EN 14511 e EN 14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità turbo; lunghezza linee frigorifere 5 m.
(2) EER/COP in accordo alla Normativa (EN 14511), dichiarati solo al fine delle detrazioni fiscali in vigore all’atto della realizzazione di questa pubblicazione.
(3) Dati in accordo con il regolamento delegato (UE) N.626/2011.
(4) Riscaldamento (EN 14511 e EN 14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità turbo; lunghezza linee frigorifere 5 m.
(5) La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN 60335-1 e EN 60335-2-40.
(6) Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale.
36