PRE-ASSEMBLED STAINLESS STEEL HANDWASH BASINS

TECHNICAL NOTES, INSTALLATION AND SERVICE ADVICES

FAULT

CAUSE

REMEDY

� KNEE OPERATED TAPS

the tap remain always open or leak

blocked tank, foreign body under the flat

washer, foreign body on the special washer

unscrew the cover under the handle and take

out the cartridge. Clean carefully the flat

washer and the special washer. Reassemble

the cartridge without put any grease inside. If

the cartridge parts are worn-out, replace them

with the “indivisible kit”

water leakage undder the handle tap

pushbutton o-ring worn-out

take away the cartridge. Using an hexagonal

pipe spanner 7 mm. Disassemble the stainless

steel needle. Replace the pushbutton o-ring

Ø 6,07x1,78

� PEDAL CONTROL

the tap or the mixer leak

foreign body is on flat washer seal

dismount the tap or the mixer and clean carefully

the flat washer seal of the mixing device.

If the washer is worn out use the other side,

rarely happen that this washer have to be

replaced becaude the closing happen always

softly

the mixer supply water not sufficiently hot

the boiler temperature is too low, is lower than

40°C

carry the temperature of the water heater over

45°C

hot water inlet filter is partially obstructed

clean the filter

majority of cold water in the system

reduce the cold water flow rate at the inlet of

the mixer

� INFRARED CONTROL WITH BATTERY

the fitting do not work and do not supply water

empty battery

dismount the tight-ness box and replace the

battery

the fitting remain always open

magnetic valve blocked

if the electronic car-

tridge result working,

wash carefully the

magnetic valve

dal 1980

MADE IN ITALY