Characteristic curves - Curvas Características
n ≈ 3450 rpm
240
220
200
Hm
160
140
120
100
80
60
40
20
700
600
ft
500
400
300
200
100
0
Test results with clean cold water, without
gas content.
A safety margin of + 0.5 m is recommended
for the NPSH value.
Head and power values valid for liquids
with density ρ = 1,0 kg/dm
3
and kinematic
viscosity ν = max 20 mm
2
/sec.
Tolerances in accordance with UNI EN ISO
9906:2012.
Pst Power with reference to one stage.
P2 Rated motor power output.
0 U.S. g.p.m. 25
50
75
100
125
MXV 50-2010-60
9
8
7
6
5
4
3
2
1
0
3
0
Q
m/h
10
20
30
500
η%
Pst
60
1
kW
40
0
8
0
l/min
100
80
2
200
300
400
34
Pst
η
NPSH
m
4
20
ft
10
0
0
0
Q m
3
/h
10
20
30
72.937/1
34
Performance - Prestaciones
Pump type
Bomba tipo
MXV 50-2001-60
MXV 50-2002-60
MXV 50-2003-60
MXV 50-2004-60
MXV 50-2005-60
MXV 50-2006-60
MXV 50-2007-60
MXV 50-2008-60
MXV 50-2009-60
MXV 50-2010-60
kW
HP
2,2
4
5,5
7,5
9,2
11
15
15
18,5
18,5
P2
3
5,5
7,5
10
12,5
15
20
20
25
25
Motor
M90V1
M112V1
M132V1
M132V1
M160V1
M160V1
M160V1
M160V1
M160V1
M160V1
m
3
/h
Q
l/min
H
m
0
0
22,4
45,1
68,0
90,0
113
136
159
181
205
228
9
150
19,5
41,0
63,5
83,5
106
128
149
171
193
215
12
200
18,9
39,6
61,5
81,0
104
125
146
167
189
210
15
250
18,3
38,2
60,0
79,0
101
121
142
162
184
204
18
300
17,4
36,6
58,0
76,0
98
117
137
157
178
197
21
350
16,3
34,7
55,5
72,0
93
112
131
149
169
188
24
400
14,7
32,1
51,5
67,0
87
104
122
139
158
176
27
450
12,6
28,7
47,0
60,0
78
94
110
125
143
159
30
500
10,1
24,4
40,5
51,5
68
81
94
108
124
138
34
566
6,0
17,3
29,5
37,0
49
59
68
78
91
102
161
Resultados de las pruebas con agua fría y
limpia, sin gas.
Para el valor del NPSH se recomienda un
margen de seguridad de + 0,5 m.
Los valores de presión y potencia son válidos
para líquidos ρ = 1,0 kg/dm
3
y viscosidad
cinemática ν = max 20 mm
2
/sec.
Tolerancia según UNI EN ISO 9906:2012.
Pst Potencia referida a un elemento.
P2 Potencia nominal del motor.