I-MPC

Construction

Self-priming swimming pool pumps with built-in strainer and motor insulated

from pumped water.

The pump is made with high quality plastic materials, corrosion and sand

erosion resistant.

With stainless steel di

ffuser.

Base-plate kit.

Applications

For water circulation in swimming pool filtration systems.

For clean or slightly dirty water with solids in suspension.

Operating conditions

Liquid temperature from 0 °C to +40 °C.

Ambient temperature up to 40° C.

Maximum permissible pressure in the pump casing 2,5 bar.

Continuous duty.

Motor

2-pole induction motor.

Nominal speed 3970 rpm

- Motor: variable speed

Frequency: 50-60 Hz

Single-phase 220-240V~50Hz/220V~60Hz, with thermal protector.

Cable: H07RN8-F, 3G1,5 mm2, length 1,5 m, with plug

CEI-UNEL 47166.

Insulation class F.

Protection IP X4.

Constructed in accordance with EN 60034-1, EN 60335-1, EN 60335-2-41.

Features

• integrated frequency converter

• high efficiency asynchronous motor

• motor power control

• voltage and current control

• monitoring of maximum starting current

Protections

• dry-run protection

• detects the presence of air in the pump casing

• overload control and overheating motor control

• pump blockage

• power supply control

• starts per hour control

• detects small leakages in the system

Designation

Example: I-MPCM 31

I = Version with integrated frequency converter

MPC = Series

M = Singlephase version (no indication: threephase)

31 = Pump type

Materials

Components

Pump casing

Diffuser cover

Impeller

Strainer cover

Strainer basket

Diffuser funnel and wear-ring

Mechanical seal

Materials

Noryl PPO-GF30

Noryl PPO-GF30

Noryl PPO-GF30

Lexan

Polypropylene

Steel 1.4401 EN 10088 (AISI 316)

Carbon - Ceramic - FPM

Performance

Single-phase

Model

Q = Flow

230V

P1

A

kW

m3/h

0

2

4

6

8

10

12

14

16

l/min

33,3

66,6

100

133

H (m) = Total head

167

200

233

267

I-MPCM 31

4,6

1,05

15,6

15,6

15,2

14,4

13,4

11,9

10,2

8,1

5,6

P1: Maximum power input.

P2: Rated motor power output.

H: Total head in m.

Tolerances according to UNI EN ISO 9906:2012