MXA

60 Hz

Rated currents - Intensidades nominales

P2

Rated motor power output. - Potencia nominal del motor.

IA/IN D.O.L. starting current / Rated current - Intensidad de arranque / Intensidad nominal

kW

HP

single-phase - monofásico

1~

220V

127V

IN A

IN A

110V 110/220V

IN A

IN A

IA/IN

0,45

0,75

1,1

1,5

0,6

1

1,5

2

4,1

6,2

8

10,6

7,1

10,7

13,9

-

8,2

12,4

16

-

-

12.5/6.4

-

-

2,7

3,2

4,2

3,8

kW

HP

three-phase - trifásico

3~

220/380V 220/440V

IN A

IN A

IA/IN

0,45

0,75

1,1

1,5

0,6

1

1,5

2

3,5/2

4,5/2,6

5,6/3,2

9/5,2

3,5/2

4,5/2,6

5,6/3,2

9/5,2

4,8

5,6

8,4

6,1

Features - Características constructivas

3.93.124

Extra safety

against running dry, with the suction port above pump axis and

with the self-priming construction.

Robust

Single-piece barrel casing.

Compact

Single-piece lantern bracket and base.

Low noise

with the water-filled shroud around the stages.

Más seguridad

Contra el funcionamiento en seco, con la boca de aspiración

sobre el eje de la bomba y con la ejecución autoaspirante.

Robusta

Cuerpo bomba de una sola pieza abierto por un solo lado.

Compacta

Acoplamiento bomba motor y base soporte de una sola pieza.

Silenciosa

con la capa de agua alrededor a los elementos.

248