GKC 60 Hz

Construction

Submersible pumps with single-channel impeller.

It offers reliability against clogging and features wide through sections and a

good resistance to wear, low mechanical action on the fluid, high hydraulic

efficiency.

Low vibrations thanks to the dynamically balanced impeller.

Delivery port DN 65-80-100-150-200-250

Applications

Particularly suitable for clean water, water containing solid and fibrous solids,

cloacal water, sewage and sludge.

Particularly suitable for the emptying of sewage from cesspits or primary

collection tanks or industrial waste water.

Motor

Induction motor 2,4,6,8 poles, 60Hz

Three-phase version:

460V ± 10%, up to 4,8 kW

460/795V ± 10% from 5,8 kW

Isolation class: H

Degree of protection: IP 68

Max number of starts per hour:

- 20 up to 5 kW

- 15 up to 10 kW

Cable: length 10m

- 10 for higher powers

Direction of rotation: clockwise top view

Motor suitable for operation with frequency converter.

Solid passage from 40 to 163 mm.

Operating conditions

Liquid temperature: from 0°C to +40°C.

Maximum immersion depth: 20m (with cable of suitable length).

Maximum working pressure: 80 m.w.c.

pH of the liquid to be lifted: 4 ÷ 10

Continuous service (with water at minimum immersion level).

Materials

Pump casing: cast iron EN-GJL250 UNI-EN 1561-11

Impeller: cast iron EN-GJL250 UNI-EN 1561-11

Motor casing: cast iron EN-GJL250 UNI-EN 1561-11 / EN-GJL450 UNI-EN

1561-11

Shaft: stainless steel X20Cr13 (AISI420)

Mechanical seal pumps with insulation class H

Designation

GKC4 100-80A-0058R-60

GK = Series

C = Single-channel impeller

4 = Number of poles

100 = Delivery port diameter in mm

80 = Free passage in mm

A = Impeller trim

0058 = Motor size kW x 10

R = With cooling jacket

60 = Frequency 60 Hz

- motor side: graphite/ceramic

- pump side: silicon/ceramic carbide

Mechanical seal pumps with insulation class F

- motor side: stainless steel/graphite

- pump side: Silicon carbide/silicon carbide

Technical data

TYPE

GKC6 80-75G-0015H-60

GKC6 80-75D-0015H-60

GKC6 80-75A-0018H-60

GKC4 80-75G-0029H-60

GKC4 80-75D-0037H-60

GKC4 80-75C-0046H-60

GKC4 80-75A-0058H-60

Dry chamber version

Vertical Horizontal

#

#

#

#

#

#

#

#

#

#

#

#

#

#

Probes

thermal conductivity

Cable

Class

Isolation

/Efficiency

H / IE3

H / IE3

H / IE3

H / IE3

H / IE3

H / IE3

H / IE3

Duck foot coupling

SAK 80-80-2

SAK 80-80-2

SAK 80-80-2

SAK 80-80-2

SAK 80-80-2

SAK 80-80-2

SAK 80-80-2

Submersible

pump rest

APK 80

APK 80

APK 80

APK 80

APK 100

APK 100

APK 80

Dry chamber

pump rest

APCK 80

APCK 80

APCK 80

APCK 80

APCK 100

APCK 100

APCK 80

Dry chamber

pump support

SOK80/N3

SOK80/N3

SOK80/N3

SOK80/N3

SOK100/N3

SOK100/N3

SOK80/N3

NSSHOU-J

H07RN-F

GKC6 100-80L-0018H-60

#

#

H / IE3

SAK 100-100-2A

APK 100

APCK 100

SOK100/N3

GKC6 100-80G-0018H-60

#

#

H / IE3

SAK 100-100-2A

APK 100

APCK 100

SOK100/N3

GKC4 100-80L-0058H-60

#

#

H / IE3

SAK 100-100-2A

APK 100

APCK 100

SOK100/N3

GKC4 100-80G-0058H-60

#

#

H / IE3

SAK 100-100-2A

APK 100

APCK 100

SOK100/N3

GKC4 100-100G-0230N-60

#

H / IE3

SAK 100-100-2

APK 150

APCK 150A

GKC4 100-100L-0230N-60

#

H / IE3

SAK 100-100-2

APK 150

APCK 150A

• = Standard

- = Not present

o = Optional

# = Version with oil chamber

# = In case of operation in a dry chamber

introduce the cooling oil according to the

or with a low level of the pumped liquid, it is necessary to

quantities indicated in the use and maintenance manual

307