Submersible pumps with multi-channel impeller.
Characterised by good protection against clogging, large spherical passages,
good wear resistance, low mechanical action on the fluid and high hydraulic
efficiency at high flow rates.
Low vibrations thanks to the dynamically balanced impeller.
Delivery port DN 200-250-300-350.
Induction motor 4-6 and 8 poles, 60Hz
460/795V ± 10%
Isolation class: H
Degree of protection: IP 68
Max number of starts per hour:
- 20 up to 5 kW
- 15 up to 10 kW
Cable: length 10m
- 10 for higher powers
Direction of rotation: clockwise top view
Motor suitable for operation with frequency converter.
For the movement of sewage and sewage grates.
Particularly suitable for the emptying of sewage from cesspits or primary
collection tanks or industrial waste water.
They replace single-channel pumps when a high solids passage diameter is not
required.
Solid passage from 100 to 164 mm.
Liquid temperature: from 0°C to +40°C.
Maximum immersion depth: 20m (with cable of suitable length).
Maximum working pressure: 80 m.w.c.
pH of the liquid to be lifted: 4 ÷ 10
Continuous service (with water at minimum immersion level).
Pump casing: cast iron EN-GJL250 UNI-EN 1561-11
Impeller: cast iron EN-GJL250 UNI-EN 1561-11
Motor casing: cast iron EN-GJL250 UNI-EN 1561-11 / EN-GJL450 UNI-EN
1561-11
Shaft: stainless steel X20Cr13 (AISI420)
Mechanical seal pumps with insulation class H
- motor side: graphite/ceramic
- pump side: silicon/ceramic carbide
Mechanical seal pumps with insulation class F
- motor side: stainless steel/graphite
- pump side: Silicon carbide/silicon carbide
GKN4 200-100A-0260R-60
GK = Series
N = Multi-channel impeller
4 = Number of poles
200 = Delivery port diameter in mm
100 = Free passage in mm
A = Impeller trim
0260 = Motor size kW x 10
R = With cooling jacket
60 = Frequency 60 Hz
TYPE
GKN4 200-110L-0260N-60
GKN6 200-110L-0110N-60
GKN6 200-110G-0110N-60
GKN6 200-110A-0150N-60
GKN6 250-115G-0195P-60
Dry chamber version
Vertical Horizontal
•
–
•
–
•
–
•
–
#
–
Probes
thermal conductivity
•
•
•
•
•
•
•
•
•
•
Cable
Class
NSSHOU-J H07RN-F Isolation
•
–
H
•
–
H
•
–
H
•
–
H
•
–
H
Duck foot coupling
SAK 200-250-3
SAK 200-250-3
SAK 200-250-3
SAK 200-250-3
SAK 250-300-3
Submersible
pump rest
APK 150
APK 150
APK 150
APK 150
APK 250
Dry chamber
pump rest
APCK 200
APCK 200
APCK 200
APCK 200
APCK 250
Dry chamber
pump support
–
–
–
–
–
GKN6 200-100L-0075N-60
#
–
•
•
•
–
H
SAK 200-250-3
APK 150
APCK 200
SOK150/N3
GKN8 300-143G-0250Z-60
–
–
•
•
–
•
F
SAK 300-350-3
APK 350
–
–
GKN8 300-143A-0340Z-60
$
$
•
•
–
•
F
SAK 300-350-3
–
APCK 300
SOK350-200
GKN8 300-143H-0250Z-R-60
–
–
•
•
–
•
F
SAK 300-350-3
APK 350
–
–
GKN8 300-143B-0340Z-R-60
$
$
•
•
–
•
F
SAK 300-350-3
–
APCK 300
SOK350-250
GKN6 300-143N-0420R-60
–
–
•
•
–
•
F
SAK 300-350-3
APK 350
–
–
GKN6 300-143I-0510R-60
$
$
•
•
–
•
F
SAK 300-350-3
–
APCK 300
SOK350-250
GKN6 300-143P-0420R-R-60
$
$
•
•
–
•
F
SAK 300-350-3
–
APCK 300
SOK350-250
GKN6 300-143L-0510R-R-60
$
$
•
•
–
•
F
SAK 300-350-3
–
APCK 300
SOK350-250
GKN6 300-143G-0600T-60
$
$
•
•
–
•
F
SAK 300-350-3
–
APCK 300
SOK350-250
GKN6 300-143D-0820T-60
$
$
•
•
–
•
F
SAK 300-350-3
–
APCK 300
SOK350-250
GKN6 300-143A-1000T-60
$
$
•
•
–
•
F
SAK 300-350-3
–
APCK 300
SOK350-250
GKN6 300-143H-0600T-R-60
$
$
•
•
–
•
F
SAK 300-350-3
–
APCK 300
SOK350-250
GKN6 300-143E-0820T-R-60
$
$
•
•
–
•
F
SAK 300-350-3
–
APCK 300
SOK350-250
GKN6 300-143B-1000T-R-60
$
$
•
•
–
•
F
SAK 300-350-3
–
APCK 300
SOK350-250
GKN8 350-163V-0340R-60
–
–
•
•
–
•
F
SAK 350-400-3
APK 350
–
–
GKN8 350-163O-0420R-60
–
–
•
•
–
•
F
SAK 350-400-3
APK 350
–
–
GKN8 350-163W-0340R-R-60
•
•
•
•
–
•
F
SAK 350-400-3
–
APCK 350
SOK350-225
GKN8 350-163P-0420R-R-60
•
•
•
•
–
•
F
SAK 350-400-3
–
APCK 350
SOK350-250
• = Standard
o = Optional
- = Not present
# = Version with oil chamber
$ = Version with cooling jacket
# = In case of operation in a dry chamber or with a low level of the pumped liquid, it
is necessary to introduce the cooling oil according to the quantities indicated in the
use and maintenance manual