How to select a centrifugal pump
The pump type NM 50/20BE can be chosen (see pump diagram)
ACCESSORIES FOR WATER SUPPLY
Foot valve with strainer - Sealing member installed on the lower end of the suction pipe. It prevents the water coming out from the piping and pump at
every plant stop. It must be always immersed in the fluid at an installation depth which allows a perfect operation without cavitation.
It is a good rule to also install a float switch to automatically stop the pump when the water goes below a fixed level.
Non-return valve - It must be installed on the pump delivery port to avoid reflux in case of a sudden stop of the plant. It is recommended using a type
fitted with an inner return spring and with ogive shutter, as this will help to diminish water hammering.
Gate valve - The installation of a gate valve is very important. In addition to allowing the pump to be dissasembled without emptying the plant, it is used
Table no. 1 Head loss in cm for bends, gate valves, foot valves and check valves
α = 90 sweep elbow
d
R
d
= 0 , 4
R
d
= 0 , 6
R
d
= 0 , 8
R
d
= 1
R
d
= 1 , 5
R
Water
flow
velocity
m/sec.
0,4
0,5
0,6
0,7
0,8
0,9
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
0,43
0,67
0,97
1,35
1,7
2,2
2,7
6,0
11
17
25
33
43
55
67
0,52
0,81
1,2
1,65
2,1
2,7
3,3
7,3
14
21
30
40
52
67
82
α
Elbows
α = 30
α = 40
α = 60
α = 80
α = 90
0,71
1,1
1,6
2,2
2,8
3,6
4,5
10
18
28
41
55
70
90
110
1,0
1,6
2,3
3,2
4,0
5,2
6,4
14
26
40
60
78
100
130
160
1,2
1,9
2,8
3,9
4,8
6,2
7,6
17
31
48
70
93
120
160
190
0,11
0,18
0,25
0,34
0,45
0,57
0,7
1,6
2,8
4,4
6,3
8,5
11
14
18
0,13
0,21
0,29
0,40
0,53
0,67
0,82
1,9
3,3
5,2
7,4
10
13
21
29
0,16
0,26
0,36
0,48
0,64
0,82
1,0
2,3
4,0
6,3
9
12
16
26
36
0,23
0,37
0,52
0,70
0,93
1,18
1,45
3,3
5,8
9,1
13
18
23
37
52
0,43
0,67
0,97
1,35
1,7
2,2
2,7
6
11
17
25
33
42
55
67
Gate
valves
0,23
0,37
0,52
0,70
0,95
1,20
1,45
3,3
5,8
9,1
13
18
23
37
52
Foot
valves
32
33
34
35
36
37
38
47
61
78
100
123
150
190
220
Check
valves
31
32
32
32
33
34
35
40
48
58
71
85
100
120
140
to start the plant and to adjust the flow.
PIPING
The piping must be selected in-line with the water velocity which is recommended to be 1.5 meter per second on the suction side and 3 meter per
second on the delivery side. The calculation of the suction piping must be carefully checked so as to avoid the maximum head loss and allow the
pumps maximum suction capability. The piping must be perfectly tight and have no counterslopes towards the pump port, so to avoid the development
or entrapment of air bubbles or pockets.
All the piping must be secured to rests, so that they will not weigh on the pump ports.
Table no. 2 Head loss in m for steel pipes
Tubo
G
Ømm
Q m
3
/h
1
3
6
9
12
18
24
30
36
42
48
60
90
120
180
240
300
360
420
500
600
Q l/min
16
50
100
150
200
300
400
500
600
700
800
1000
1500
2000
3000
4000
5000
6000
7000
8333
10000
G 1/2
DN 15
HL
v
m/100m
m/s
29,9
1,6
G 3/4
DN 20
7,4
0,9
56,3
2,7
G 1
DN 25
2,5
0,6
19,0
1,7
68,6
3,4
G 11/4 DN 32
0,7
0,3
5,7
1,0
20,6
2,1
43,6
3,1
74,4
4,1
G 11/2 DN 40
0,3
0,2
1,9
0,7
6,9
1,3
14,7
2,0
25,1
2,7
53,1
4,0
90,5
5,3
G 2
DN 50
0,6
0,4
2,3
0,8
5,0
1,3
8,5
1,7
17,9
2,5
30,5
3,4
46,2
4,2
64,7
5,1
86,1
5,9
G 21/2 DN 65
0,2
0,3
0,7
0,5
1,4
0,8
2,4
1,0
5,0
1,5
8,5
2,0
12,9
2,5
18,0
3,0
24,0
3,5
30,7
4,0
46,4
5,0
DN 80
0,5
0,5
0,9
0,7
1,8
1,0
3,1
1,3
4,7
1,7
6,6
2,0
8,7
2,3
11,2
2,7
16,9
3,3
35,8
5,0
60,9
6,6
DN 100
0,6
0,6
1,0
0,8
1,6
1,1
2,2
1,3
2,9
1,5
3,8
1,7
5,7
2,1
12,1
3,2
20,6
4,2
43,6
6,4
74,2
8,5
DN 125
0,7
0,8
1,0
1,0
1,3
1,1
1,9
1,4
4,1
2,0
6,9
2,7
14,7
4,1
25,0
5,4
37,8
6,8
53,0
8,1
70,5
9,5
DN 150
0,5
0,8
0,8
0,9
1,7
1,4
2,9
1,9
6,0
2,8
10,3
3,8
15,6
4,7
21,8
5,7
29,0
6,6
40,1
7,9
56,2
9,4
DN 200
0,2
0,5
0,4
0,8
0,7
1,1
1,5
1,6
2,5
2,1
3,8
2,7
5,4
3,2
7,1
3,7
9,9
4,4
13,8
5,3
DN 250
0,2
0,7
0,5
1,0
0,9
1,4
1,3
1,7
1,8
2,0
2,4
2,4
3,3
2,8
4,7
3,4
DN 300
0,2
0,7
0,4
0,9
0,5
1,2
0,7
1,4
1,0
1,7
1,4
2,0
1,9
2,4
Q Flow.
HL Head loss, m per 100 m.
v = Flow velocity: max 1,5 m/s for suction and 3 m/s for delivery.
493