NR(D) EI, NR(D)4 EI

60 Hz

Pumps with frequency converter

The NR(D) EI, NR(D)4 EI, pumps are available with power from 0,25

kW up to 18,5 kW, the pumps are equipped with I-MAT installed on

board which allows to realize a variable-speed system extremely

compact and efficient, ideal in applications of water supply and in the

distribution of hot and cold water.

The pump is equipped with transducers suitable for

operation and is already programmed at the

factory.

Advantages

- Energy saving

- Compact design

- Easy to use

- Programmable to suit the system requirements

- Reliability

Costruction

The system comprises of:

- Pump

- Induction motor (2 for NRD, NRD4)

- I-MAT Frequency converter (2 for NRD, NRD4)

- Motor adapter for the motor mounting of the

frequency converter (2 for NRD, NRD4)

- Connection cable between frequency converter

and induction motor

- Transducers

- Communication cable for cascade mode for NRD,

NRD4

- 2 Cascade mode expansion board for NRD, NRD4

Main features

Rated motor power output from 0,25 kW to 18,5 kW

Control range from 1750 to 3450 rpm (2-pole)

Control range from 870 to 1750 rpm (4-pole)

Protection against dry running

Protection against operations with closed valve ports

Protection against system leakages

Protection against overcurrent in the motor

Protection agains overvoltage and undervoltage of the power supply

Protection against current unbalances between phases

Bomba a velocidad variable

La bomba NR(D) EI, NR(D)4 EI, se encuentra disponible con potencias

de 0,25 kW a 18,5 kW y llevan incorporado un variador I-MAT que

permite realizar un sistema de velocidad variable extremadamente

compacto y eficiente, ideal para aplicaciones de abastecimiento de agua y

la distribución de agua fría y caliente.

Bomba eléctrica es suministrada con un transductor

de presión idóneo para el modo operaci

ón que escoja

el cliente y programado directamente desde fábrica

Ventajas

- Ahorro de energía

- Diseño compacto

- Fácil de usar

- Programable para las necesidades del sistema

- Fiabilidad

Construcción

-

-

-

-

-

-

-

-

El sistema está compuesto por:

Bomba

Motor de inducción (dos para NRD, NRD4)

I-MAT variador de frecuencia (dos para NRD, NRD4)

Adaptador del motor para el montaje del variador de

frecuencia (dos para NRD, NRD4)

Cable de conexión entre en variador y la bomba

eléctrica

Transductores

Cable de comunicación multibomba paraNRD,

NRD4

- 2 Tarjeta expansión multibomba para NRD, NRD4

Límites de utilización

Potencia nominal del motor desde 0,25 kW hasta 18,5 kW

Rango de control desde 1750 hasta 3450 rpm (2 polos)

Rango de control desde 870 hasta 1750 rpm (4 polos)

Protección contra el funcionamiento en seco

Protección contra el funcionamiento con válvula cerrada

Protección contra fugas del sistema

Protección contra sobrecorriente del motor

Protección contra sobrevoltaje o bajovoltaje de la red de alimentaci

ón

Protección contra el desequilibrio de fases

Operating modes

Constant pressure mode

with pressure transducer

In this mode, the system maintains the preset pres-

sure when the flow required by the installation

changes.

Proportional pressure mode

with pressure transducer

In this mode the system changes the working pres-

sure according to the required flow rate.

Constant flow mode

with flow meter

In this mode the system maintains a constant flow

rate value in a point of the installation according to

the required pressure.

Modo presión constante

con sensor de presión

En el modo de presión constante, el sistema mantie-

ne la presión prefijada cuando cambia el caudal por

los cambios de la instalación.

Modo caudal constante

con medidor de caudal

En el modo caudal constante el sistema mantiene el

caudal constante en un punto de la instalación de

acuerdo a la presión requerida.

H

Modo presión proporcional

con sensor de presión

En el modo de presión proporcional, el sistema cam-

bia la presión de trabajo de acuerdo al caudal reque-

rido.

H

+

-

H

-

Q

+

Fixed speed mode

with setting of the speed preferential rotation.

In this mode, by changing the working frequency,

you may choose any operational curve included

within the working range.

Constant temperature mode

with temperature transducer

In this mode the system keeps the temperature

constant inside a system by changing the speed of

the pump.

Modo velocidad fija

con el ajuste de la velocidad de rotación preferencial

En el modo velocidad fija, cambiando la frecuencia

de trabajo, se puede escoger cualquier curva opera-

tiva dentro del rango de trabajo de la bomba.

Modo temperatura constante

con sensor de temperatura

En este modo el sistema mantiene la temperatura

constante dentro de un sistema cambiando la veloci-

dad de la bomba.

+

-

min

max

Q

Modos de operación

H

+

-

Q

90