F
I
L
T
E
R
S
-
C
A
R
T
R
I
D
G
E
56
Sta-Rite’s modular media filtration is a great match for both the inground and aboveground pool markets. Advances in media
technology and balanced flow design provide the optimal dirt holding capabilities. The small diameter footprint makes the
System:2 filter a great fit for new and retrofit installations.
Modular Filter Tanks allows for quick change of
filter medias without changing the tank. Contemporary style and matte black
finish looks attractive in any pool setting.
• Typical Installation – aboveground pools, inground pools,
and inground hot tubs
• Quality Construction – Durable two-piece tank housing
constructed of rugged ABS thermoplastic to ensure a long-
lasting tank life
• Easy Access – Posi-Ring Locking Ring provides fast
access to tank internals
• Innovative Design – The innovative balanced flow design
firstintroducedwiththeSystem 3ModMediafilteris
available in the smaller System:2 filter
• Low Maintenance – Complete media coverage combined
with shallow pleats means greater dirt holding capabilities,
resulting in longer filter cycles and less cleaning
• Large Drain Plug – Filter includes 2 in. NPT Drain ports,
which are provided with reducer bushing and 1-1/2 in.
drain plug
PLM100
100
PLM150
150
PLM200
200
38–100
14–36,000
56–150
20–54,000
75–150
27–54,000
18–48,000
27–72,000
36–72,000
23–60,000
34–90,000
45–90,000
2 in.
41
2 in.
43
2 in.
45
Product
Effective Filter
Area (Sq. Ft.)
Flow Rated
1
GPM (Sq. Ft.)
Turnover Capacity (In Gallons)
(Flow Rate x 60 x Hours)
Tank Port
Size
Carton
Wt. (Lbs.)
6 Hour
8 Hour
10 Hour
SYSTEM:2 MODULAR MEDIA FILTER - PLM SERIES
PLM125
125
47–125
17– 45,000
22–60,000
28–75,000
2 in.
42
PLM175
175
66–150
24–54,000
31–72,000
39–90,000
2 in.
44
PLM300
300
113–150
41–54,000
54–72,000
68–90,000
2 in.
53
1
Based on NSF recommended flow rate for commercial at .375 GPM per
square foot.
Note: No backwash valve required.
Note: Operating Limits – maximum continual operating pressure of 50 PSI.
Pool/spa (bather) applications, maximum operating water temperature
(internal filter) 104°F (40°C).
CALIFORNIA PROPOSITION 65 WARNING
WARNING: Cancer and Reproductive Harm.
AVERTISSEMENT: Peut Causer le Cancer
et des Dommages au Système Reproducteur.
ADVERTENCIA: Cáncer y Daño Reproductivo.
www.p65warnings.ca.gov.
P/N 200174.A