CARATTERISTICHE TECNICHE
Via Antonio Meucci, 22/24 – Zona Ind.le “Maestri del Lavoro”
62027 San Severino Marche (MC)
Tel. 0733-645675 – Fax 0733-645780
e-mail: info@multiclimasrl.com web: www.multiclimasrl.com
DECLARATION OF PERFORMANCE (Reg. UE n. 305/2011 annex III)
No. CF/0713_MLCM
1
Unique identification code of the product type :
CF (single wall)
2
Type,batch or serial number
or any other element
allowing identification of
the construction product as
required pursuant to Article
11(4):
Connecting flue pipe CF (without gasket) UNI EN 1856-2: T600-N1-D-Vm-L50200-G600 (M)
Flue linear CF (without gasket) UNI EN 1856-2: T600-N1-D-Vm-L50200-G
Intended use or uses of the construction product, in
3
accordance with the applicable harmonised technical
specification, as foreseen by the manufacturer:
Name, registered trade name or registered trade mark
4
and contact address of the manufacturer as required
pursuant to Article 11(5):
Name and contact address of the authorised
5
representative whose mandate covers the tasks specified
in Article 12(2):
System or systems of assessment and verification of
6
constancy of performance of the construction product as
Connecting flue pipe and flue linear to convey
the combustion products into the atmosphere.
MULTICLIMA S.r.l.
Via Antonio Meucci, 22/24 – Zona Ind.le “Maestri del Lavoro”
62027 – San Severino Marche – (MC)
N.A.
System 2 +
UNI EN 1856-2
Istituto Giordano S.p.A.
Notifiy No. 0407
Inspection of manufacturing process and of FPC guide.
Checking of constancy of performance, checking of conformity of
the factory production control.
No 0407-CPR-049 (IG-124-2005)/7
7
set out in Annex V:
In case of the declaration of performance concerning a
construction product covered by a harmonised standard:
Notified Institution :
Description of the third party tasks as set out in Annex V
Certificate of conformity of the factory production
control (FPC):
8
European technical assessment
Compression resistance
Fire resistance
Gas thightness
Flow resistance
9
Thermal resistance
Thermal shock resistance
Flexural resistance
Duration against chemical agents
Duration against corrosion
Duration against ice and melting of ice
Dangerous substances:.
N.A.
DECLARED PERFORMANCE :
N.P.D.
G (600)
N1
0,001 mm
N.P.D.
Positive ( without gasket)
N.P.D.
N.P.D.
N.P.D.
N.P.D.
EN1856-2:2009
EN1856-2:2009
EN1856-2:2009
EN1856-2:2009
EN1856-2:2009
EN1856-2:2009
EN1856-2:2009
EN1856-2:2009
EN1856-2:2009
EN1856-2:2009
Missing and/or according to the current regulations.
10
The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 9.
This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4.
Signed for and on behalf of the manufacturer by
GABRIELE BONCI (DIRECTION)
SAN SEVERINO MARCHE 01.07.2013
DECLARATION OF PERFORMANCE No. CF/0713_MLCM
Diametri / Diameters / Diamètres
Materiale / Material / Matériau
Signature
T600 – N1 – D – Vm – L05200 G600 (M)
CANALE DA FUMO SENZA GUARNIZIONE
T600 – N1 – D – Vm – L05200 – G
CONDOTTO FUMARIO SENZA GUARNIZIONE
T600 – N1 – D – Vm – L05200 G600 (M)
CONNECTING FLUE PIPE WITHOUT GASKET
T600 – N1 – D – Vm – L05200 – G
FLUE LINER WITHOUT GASKET
T600 – N1 – D – Vm – L05200 G600 (M)
CANAL DE FUMÉE SANS JOINT
T600 – N1 – D – Vm – L05200 – G
CONDUIT DE FUMÉE SANS JOINT
CAMPO DI APPLICAZIONE:
APPLICATION
APPLICATION
TEMPERATURA DI ESERCIZIO
OPERATING TEMPERATURE
TEMPÉRATURE DE FONCTIONNEMENT
COMBUSTIBILI AMMESSI
ALLOWED FUELS
COMBUSTIBLES ADMIS
RESISTENZA AL FLUSSO
FLOW RESISTANCE
RÉSISTANCE AU FLUX
TENUTA AI GAS N1
N1 GAS TIGHTNESS
ÉTANCHÉITÉ AUX GAZ N1
EVACUAZIONE DEI FUMI CONDENSATI O SECCHI PER FUNZIONAMENTO IN N1
EVACUATION OF CONDENSED OR DRIED SMOKES FOR N1 OPERATIONS.
ÉVACUATION DES CONDENSATS OU FUMÉES SÈCHES POUR UN FONCTIONNEMENT EN N1.
MULTICLIMA S.r.l.
MULTICLIMA S.r.l.
Via Antonio Meucci, 22/24 – Zona Ind.le “Maestri del Lavoro”
62027 San Severino Marche (MC)
Tel. 0733-645675 – Fax 0733-645780
e-mail: info@multiclimasrl.com web: www.multiclimasrl.com
Standard / Standard / Standard:
DIAMETRI MAGGIORI A RICHIESTA / Bigger diameters on request / Diamètres plus grands sur demande
ACCIAIO ALLUMINATO Sp. 20/10
ALUMINIZED STEEL PIPE 20/10 thickness / ACIER ALUMINÉ épaisseur 20/10
Designazione del prodotto (EN 1856-1 e 1856-2)
Product Designation (EN 1856-1 e 1856-2) / Désignation du produit (EN 1856-1 e 1856-2)
0,001 mm
4,310
-4
m
3
/ (sm2)
N.A.
Rapporto di prova
n° 235737
Test report
Rapport du test
3,210
-4
3
m / (sm2)
140 - 150 - 160 - 180 - 200 - 230 - 250 - 300
600° C IN PRESSIONE NEGATIVA N1
600°C IN NEGATIVE PRESSURE N1
600°C AVEC PRESSION NEGATIVE N1
SOLIDI CON FUNZIONAMENTO A SECCO
SOLID FUELS WITH DRY RUNNING
COMBUSTIBLES SOLIDES AVEC UN FONTIONNEMENT À SEC.
RESISTENZA TERMICA
THERMAL RESISTANCE
RÉSISTANCE THERMIQUE
PRIMA DELLA PROVA DI SHOCK TERMICO
DOPO LA PROVA DI SHOCK TERMICO
BEFORE THERMAL SHOCK TEST
AFTER THERMAL SHOCK TEST
AVANT LE TEST DU SHOCK THERMIQUE
APRÈS LE TEST DU SHOCK THERMIQUE
3