B
I
G
F
P
R
O
BIG F PRO
WORKING CONDITIONS
SPECIFICATIONS
CONTROL PANEL
Material
Power cable
Resettable days meter
Dimension
Feed plug
Audio alarm
Protection class
Monitor display
Power supply
Days meter
Thermoplastic
2 mt
For lamp life control
218x113x60 mm
AUS Type I
With silence options
IP 54
Digital
110-240 V - 50/60 Hz
For total system life
722 mm
205 mm
7
9
0
m
m
Max working pressure ______12,05 bar (174,8 psi)
Max working temperature ____45°C (113°F)
Non-toxic materials, suitable for drinking water.
Filter Head: reinforced polypropylene.
Filter bowl: reinforced polypropylene.
O-ring: EPDM.
Breather-valve: body polypropylene, o-ring EPDM.
Metal frame: Varnished galvanized steel with key lock
BIG F PRO - 156
2 STAGE FILTRATION SYSTEM WITH UV TREATMENT
CODE
MODEL
RA9116574 BIG F PRO 156
*UVC TRANSMITTANCE: 95% - 1 cm
UV LAMP
LIFESPAN
LAMP POWER
TYPE
UV REACTOR
MATERIAL
CONNECTIONS
MAX WORKING PRESSURE
PROTECTION CLASS
SUITABLE
CARTRIDGE
10”
IN/OUT
1”
SHIPPING
WEIGHT
20 Kg
FLOW
RATE*
54 lpm (40mJ/cm
2
)
TOTAL
CONSUMPTION
61 W
9000 hrs
56 W
HO low pressure
Stainless Steel 304
Thread 1” M
12,05 bar
IP 54
CARTRIDGES CONFIGURATION
- stage 1: TS 10” BIG - 20 micron
- stage 2: CPP 20” BIG - 1 micron
155 | BIG F PRO