CERTIFICAZIONI DI PRODOTTO

Certi

ficato di prodotto solare termico Per i modelli Favignana

Annex to Solar Keymark Certificate

Page 1/2

Licence Number

SC0140-18

Annex to Solar Keymark Certificate - Summary of EN 12975-2

Test Results

Date issued

2018-03-16

Issued by

RISE

Licence holder

Cordivari S. R. L.

Countr

y

Ital

y

Brand (optional)

CVT

We

b

http://www.cordivari.it/

Street, Number

Zona Industriale Pagliare – 64020 morro d’oro

E-mai

l

info@cordivari.i

t

Postcode, City

Teramo

Tel

+39 085 80401

Collector Type

Evacuated tubular collecto

r

G

r

o

s

s

a

r

e

a

(

A

G

)

Power output per collector

Gb = 850 W/m²; Gd = 150 W/m

²

ϑm - ϑa

G

r

o

s

s

l

e

n

g

t

h

G

r

o

s

s

w

i

d

t

h

G

r

o

s

s

h

e

i

g

h

t

0 K

10 K

30 K

50 K

70 K

64

K

Collector name

m²

mm

mm

mm

W

W

W

W

W

W

CVT1

0

2,17

1 917

1 130

133

1 175

1 147

1 088

1 021

947

970

CVT1

5

3,22

1 917

1 680

133

1 743

1 703

1 614

1 515

1 406

1 440

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Power output per m² gross are

a

541

529

501

471

437

447

Performance parameters test method

Steady state - outdoor

Performance parameters (related to AG)

η0,hem a1

a2

Unit

s

Test result

s

- W/(m²K)

0,541

1,212

W/(m²K²

)

0,004

0,180

0,000

0,000

0,91

0

Incidence angle modifier test method

Quasi dynamic - outdoo

r

Bi-directional incidence angle modifiers

Yes

Incidence angle modifier

Angle

10°

20°

30°

40°

50°

60°

70°

80°

90°

Transversal

KθT,coll

1,03

1,05

1,18

0,00

Longitudinal

KθL,coll

0,95

0,0

0

Heat transfer medium for testin

g

Wate

r

Flow rate for testing (per gross area, AG)

dm/dt

kg/(sm²)

0,020

Maximum temperature difference for thermal performance calculations

(ϑm-ϑa)max

K

64

Standard stagnation temperature (G = 1000 W/m²; ϑa = 30 °C)

ϑstg

280

°C

Effective thermal capacity, incl. fluid (per gross area, AG)

Maximum operating temperature

C/m2

ϑmax_op

3,17

120

kJ/(Km2)

°C

1000

Maximum operating pressure

pmax,op

kPa

Testing laboratory TestLab

A

-

Test report(s)

131016040GZU-001

Dated

2014-01-07

Comments of testing laboratory

Negative mechanical load test of collector was not performed

Datasheet version: 5.01, 2016-03-0

1

Certification Body:

RISE Research Institutes of Sweden | Certificatio

n

Box 857, SE-501 15 Borås, Sweden, Phone:+46 10 516 50 00, certifiering@ri.se | www.ri.s

e

CERTIFICATO SOLAR KEYMARK

Per la documentazione completa consultare il sito www.solarkeimark.dk.

26

4

Certi

ficazione di prodotto per la gamma di prodotti

Stratos 4S Heat Storag

e

Annex to Solar Keymark Certificate

Page 2/

2

Annex to Solar Keymark Certificate

Licence Number

SC0140-18

Supplementary Information

Issued

2018-03-1

6

Annual collector output in kWh/collector at mean fluid temperature ϑm, based on EN 12975-2 test result

s

Standard Locations

Athens

Davos

Stockholm

Würzburg

Collector nam

e

ϑm

25°C 50°C 75°C 25°C 50°C 75°C 25°C 50°C 75°C 25°C 50°C 75°C

CVT1

0

1 998 1 716 1 435 1 682

1 418 1 171 1 212 992 796 1 304 1 069 854

CVT1

5

2 965 2 546 2 129 2 496 2 105 1 738 1 798 1 472 1 181 1 935 1 586 1 267

Annual output per m² gross are

a

921

791

661 775

654

540 558

457

367 601

493

393

Fixed or tracking collecto

r

Fixed (slope = latitude - 15°; rounded to nearest 5°

)

Annual irradiation on collector plane

1765 kWh/m²

1714 kWh/m²

1166 kWh/m²

1244 kWh/m

²

Mean annual ambient air temperature

18,5°C

3,2°C

7,5°C

9,0°

C

Collector orientation or tracking mode

South, 25°

South, 30°

South, 45°

South, 35

°

The collector is operated at constant temperature ϑm (mean of in- and outlet temperatures). The calculation of the annua

l

collector performance is performed with the official Solar Keymark spreadsheet tool Scenocalc Ver. 5.01 (March 2016). A detaile

d

description of the calculations is available at www.solarkeymark.org/scenocal

c

Additional Informatio

n

Collector heat transfer medium

Water-Glycole

Hybrid Thermal and Photo Voltaic collector

No

The collector is deemed to be suitable for roof integration

No

The collector was tested successfully according to EN ISO 9806:2013 under the following conditions

:

Climate class (A, B or C)

C

--

Maximum tested positive load

2860

Pa

Maximum tested negative loa

d

-

Pa

Hail resistance using steel ball (maximum drop height)

0,8

m

Energy Labelling Information

Reference Area, Asol (m2) Data required for CDR (EU) No 811/2013 - Reference Area Aso

l

CVT10

2,17

Collector efficiency (ηcol)

49

%

CVT15

3,22

Remark: Collector efficiency (η col ) is defined in CDR (EU) N

o

811/2013 as collector efficiency of the solar collector at a

temperature difference between the solar collector and the

surrounding air of 40 K and a global solar irradiance of 100

0

W/m², expressed in % and rounded to the nearest integer.

Deviating from the regulation η col is based on reference are

a

(A sol ) which is aperture area for values according to EN 12975-2

or gross area for ISO 9806:2013.

Data required for CDR (EU) No 812/2013 - Reference Area Aso

l

Zero-loss efficiency (η0 )

0,541

--

First-order coefficient (a1)

1,21

W/(m²K

)

Second-order coefficient (a2)

0,004

W/(m²K²)

Incidence angle modifier IAM (50°)

0,00

--

Remark: The data given in this section are related to collecto

r

reference area (A sol ) which is aperture area for values according

to EN 12975-2 or gross area for ISO 9806. Consistent data sets fo

r

either aperture or gross area can be used in calculations like in the

regulation 811 and 812 and simulation programs.

Certification Body:

RISE Research Institutes of Sweden | Certificatio

n

Box 857, SE-501 15 Borås, Sweden, Phone:+46 10 516 50 00, certifiering@ri.se | www.ri.s

e

CERTIFICATO SOLAR KEYMARK