Certi
ficato di prodotto solare termico Per i modelli Favignana
Annex to Solar Keymark Certificate
Page 1/2
Licence Number
SC0140-18
Annex to Solar Keymark Certificate - Summary of EN 12975-2
Test Results
Date issued
2018-03-16
Issued by
RISE
Licence holder
Cordivari S. R. L.
Countr
y
Ital
y
Brand (optional)
CVT
We
b
http://www.cordivari.it/
Street, Number
Zona Industriale Pagliare – 64020 morro d’oro
E-mai
l
info@cordivari.i
t
Postcode, City
Teramo
Tel
+39 085 80401
Collector Type
Evacuated tubular collecto
r
G
r
o
s
s
a
r
e
a
(
A
G
)
Power output per collector
Gb = 850 W/m²; Gd = 150 W/m
²
ϑm - ϑa
G
r
o
s
s
l
e
n
g
t
h
G
r
o
s
s
w
i
d
t
h
G
r
o
s
s
h
e
i
g
h
t
0 K
10 K
30 K
50 K
70 K
64
K
Collector name
m²
mm
mm
mm
W
W
W
W
W
W
CVT1
0
2,17
1 917
1 130
133
1 175
1 147
1 088
1 021
947
970
CVT1
5
3,22
1 917
1 680
133
1 743
1 703
1 614
1 515
1 406
1 440
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Power output per m² gross are
a
541
529
501
471
437
447
Performance parameters test method
Steady state - outdoor
Performance parameters (related to AG)
η0,hem a1
a2
Unit
s
Test result
s
- W/(m²K)
0,541
1,212
W/(m²K²
)
0,004
0,180
0,000
0,000
0,91
0
Incidence angle modifier test method
Quasi dynamic - outdoo
r
Bi-directional incidence angle modifiers
Yes
Incidence angle modifier
Angle
10°
20°
30°
40°
50°
60°
70°
80°
90°
Transversal
KθT,coll
1,03
1,05
1,18
0,00
Longitudinal
KθL,coll
0,95
0,0
0
Heat transfer medium for testin
g
Wate
r
Flow rate for testing (per gross area, AG)
dm/dt
kg/(sm²)
0,020
Maximum temperature difference for thermal performance calculations
(ϑm-ϑa)max
K
64
Standard stagnation temperature (G = 1000 W/m²; ϑa = 30 °C)
ϑstg
280
°C
Effective thermal capacity, incl. fluid (per gross area, AG)
Maximum operating temperature
C/m2
ϑmax_op
3,17
120
kJ/(Km2)
°C
1000
Maximum operating pressure
pmax,op
kPa
Testing laboratory TestLab
A
-
Test report(s)
131016040GZU-001
Dated
2014-01-07
Comments of testing laboratory
Negative mechanical load test of collector was not performed
Datasheet version: 5.01, 2016-03-0
1
Certification Body:
RISE Research Institutes of Sweden | Certificatio
n
Box 857, SE-501 15 Borås, Sweden, Phone:+46 10 516 50 00, certifiering@ri.se | www.ri.s
e
CERTIFICATO SOLAR KEYMARK
Per la documentazione completa consultare il sito www.solarkeimark.dk.
Certi
ficazione di prodotto per la gamma di prodotti
Stratos 4S Heat Storag
e
Annex to Solar Keymark Certificate
Page 2/
2
Annex to Solar Keymark Certificate
Licence Number
SC0140-18
Supplementary Information
Issued
2018-03-1
6
Annual collector output in kWh/collector at mean fluid temperature ϑm, based on EN 12975-2 test result
s
Standard Locations
Athens
Davos
Stockholm
Würzburg
Collector nam
e
ϑm
25°C 50°C 75°C 25°C 50°C 75°C 25°C 50°C 75°C 25°C 50°C 75°C
CVT1
0
1 998 1 716 1 435 1 682
1 418 1 171 1 212 992 796 1 304 1 069 854
CVT1
5
2 965 2 546 2 129 2 496 2 105 1 738 1 798 1 472 1 181 1 935 1 586 1 267
Annual output per m² gross are
a
921
791
661 775
654
540 558
457
367 601
493
393
Fixed or tracking collecto
r
Fixed (slope = latitude - 15°; rounded to nearest 5°
)
Annual irradiation on collector plane
1765 kWh/m²
1714 kWh/m²
1166 kWh/m²
1244 kWh/m
²
Mean annual ambient air temperature
18,5°C
3,2°C
7,5°C
9,0°
C
Collector orientation or tracking mode
South, 25°
South, 30°
South, 45°
South, 35
°
The collector is operated at constant temperature ϑm (mean of in- and outlet temperatures). The calculation of the annua
l
collector performance is performed with the official Solar Keymark spreadsheet tool Scenocalc Ver. 5.01 (March 2016). A detaile
d
description of the calculations is available at www.solarkeymark.org/scenocal
c
Additional Informatio
n
Collector heat transfer medium
Water-Glycole
Hybrid Thermal and Photo Voltaic collector
No
The collector is deemed to be suitable for roof integration
No
The collector was tested successfully according to EN ISO 9806:2013 under the following conditions
:
Climate class (A, B or C)
C
--
Maximum tested positive load
2860
Pa
Maximum tested negative loa
d
-
Pa
Hail resistance using steel ball (maximum drop height)
0,8
m
Energy Labelling Information
Reference Area, Asol (m2) Data required for CDR (EU) No 811/2013 - Reference Area Aso
l
CVT10
2,17
Collector efficiency (ηcol)
49
%
CVT15
3,22
Remark: Collector efficiency (η col ) is defined in CDR (EU) N
o
811/2013 as collector efficiency of the solar collector at a
temperature difference between the solar collector and the
surrounding air of 40 K and a global solar irradiance of 100
0
W/m², expressed in % and rounded to the nearest integer.
Deviating from the regulation η col is based on reference are
a
(A sol ) which is aperture area for values according to EN 12975-2
or gross area for ISO 9806:2013.
Data required for CDR (EU) No 812/2013 - Reference Area Aso
l
Zero-loss efficiency (η0 )
0,541
--
First-order coefficient (a1)
1,21
W/(m²K
)
Second-order coefficient (a2)
0,004
W/(m²K²)
Incidence angle modifier IAM (50°)
0,00
--
Remark: The data given in this section are related to collecto
r
reference area (A sol ) which is aperture area for values according
to EN 12975-2 or gross area for ISO 9806. Consistent data sets fo
r
either aperture or gross area can be used in calculations like in the
regulation 811 and 812 and simulation programs.
Certification Body:
RISE Research Institutes of Sweden | Certificatio
n
Box 857, SE-501 15 Borås, Sweden, Phone:+46 10 516 50 00, certifiering@ri.se | www.ri.s
e
CERTIFICATO SOLAR KEYMARK