POMPE DI CALORE / 

APPROFONDIMENTO

TECNIC

O

Dimensionali unità interna

HYDROTANK

DHW tan

k

capacity

170L

200L

1400

1600

456

456

HANDLE

±

5

0

2

0

300

L

205

0

931

5

5

2

.

7

5

3

7

.

1

4

1

2

.

1

2

4

2

.

7

1

8

2

.

7

0

67.

8

RETURN TO HEAT PUM

P

CONNECTION (28mm pipe

)

442.

3

515.

7

542.

3

FLOW FROM HEAT PUM

P

CONNECTION (28mm pipe

)

2

2

6

.

6

1

8

1

.

6

<TOP

>

680

AIR VEN

T

±

±

5

595 5

±

1

0

0

2

0

±

1

1

5

2

0

4

8

0

1

3

6

.

6

9

1

.

6

4

6

.

6

0

<BACK>

MODELLI SPLI

T

<LEFT SIDE>

5

5

2

.

7

5

3

7

.

1

4

1

2

.

1

2

4

2

.

7

1

8

2

.

7

4

8

0

<FRONT>

<RIGHT SIDE>

DHW tank

capacity

170L

200L

300

L

1400

1600

205

0

456

456

931

Refrigerant (GAS

)

(With plate heat exchanger

)

Refrigerant (LIQUID

)

(With plate heat exchanger

)

0

67.

8

442.3

515.7

542.3

AIR VENT

HANDL

E

680 ±

5

595 5

±

<TOP

>

2

2

6

.

6

1

8

1

.

6

1

3

6

.

6

9

1

.

6

4

6

.

6

0

5

0

2

0

±

1

0

2

2

0

±

1

0

0

2

0

±

1

1

5

2

0

±

<BACK>

<LEFT SIDE

>

<FRONT>

DHW OUTLET (G3/4

)

COLD WATER INLET (G3/4

)

SPACE HEATING FLOW CONNECTION (G1

)

SPACE HEATING RETURN CONNECTION (G1)

Note: G1 and G3/4 means female nut connection

.

ELECTRICAL CABLE INLETS < C >

PRESSURE

RELIEF VALVE

(SANITARY CIRCUIT)

G1/2

MANOMETER

MAIN

CONTROLLE

R

TERMINAL

BLOC

K

FRONT PANE

L

DHW OUTLET (G3/4

)

COLD WATER INLET (G3/4)

SPACE HEATING FLOW CONNECTION (G1

)

SPACE HEATING RETURN CONNECTION (G1

)

ELECTRICAL CABLE INLET

S

PRESSURE

RELIEF VALVE

(PRIMARY CIRCUIT)

PRESSUR

E

RELIEF VALV

E

(SANITARY CIRCUIT

)

G1/

2

±

1

1

8

2

0

MANOMETER

MAIN

CONTROLLER

TERMINAL

BLOCK

FRONT PANEL

<RIGHT SIDE>

<E*PT30X-*M*EE>

1

2

0

±

2

0

(

1

5

6

0

)

(

4

9

0

)

<FRONT>

<E*ST30*-*M*EE

>

1

2

0

±

2

0

(

1

5

6

0

)

(

4

9

0

)

1

5

ADJUST BOLT

6

5

<FRONT>

Pipe description

Connection size/typ

e

12.7 mm or 15.88 mm/Flare (E*ST**F-*

)

Refrigerant (GAS

)

(With plate heat exchanger

)

Descrizione attacco

Refrigerant (LIQUID

)

(With plate heat exchanger)

Tubazione refrigerante (Linea GAS)

Electrical cable inlets

(unità split

)

Warning

12.7 mm/Flare (E*ST**D-*)

• Refrigerant pipes connection shall be accessible for

15.88 mm/Flare (E*ST**C-*)

Connession

e

maintenance purposes.

6.35 mm/Flare (E*ST**F/D-*

)

• In case of reconnecting the refrigerant pipes after

9.52 mm/Flare (E*ST**C-*)

detaching, make the flared part of pipe re-fabricated.

12.7 mm o 15.88 mm/svasato (E*ST**F-*

)

For inlets

12.7 mm/svasato (E*ST**D-*

)

, and

ATTENZIONE

, run low-voltage wires including external input wires and thermistor wires.

For inlets

1 2 3 4

5

15.88 mm/svasato (E*ST**C-*

)

and

, run high-voltage wires including power cable, indoor-outdoor cable, and

• 

Le conness

ioni frigorifere devono essere

external output wires

.

accessibli per manutenzione.

*For a wireless receiver (option) cable and ecodan Wi-Fi interface (option) cable, use inlet

.

• 

In caso di ricollegamento dei tubi del refri-

6.35 mm/svasato (E*ST**F/D-*)

gerante dopo lo smontaggio, rilavorare l

a

9.52 mm/svasato (E*ST**C-*)

<Table 4.1.1>

parte svasata del tubo.

Per gli ingressi 1 2 3 , introdurre cavi a bassa tensione, inclusi i cavi degli input esterni e i termistori.

Per gli ingressi

4 5 , introdurre cablaggi in alta tensione, inclusi il cavo di alimentazione, il cavo di collegamento

interna-esterna e i cavi degli output esterni

.

*per il cablaggio del ricevitore wireless (opzionale) e per l’interfaccia wifi (opzionale) utilizzare l’ingresso

1

.

B-29

Tubazione refrigerante (Linea LIQUIDO

)

(unità split

)

Ingresso cablaggio elettrico

1 2 3 4 5

92