TEST REPORT N°
ITAH18011510/E1 Amendment of 31/08/2018
START DATE
END DATE
06/08/2018
31/08/2018
TEST METHOD
Overall Migration
Item for repetead use
REG. 10/2011 EC GU n° L12/1 +
Reg. CE 1935/2004
SAMPLE DESCRIPTION
01
PARAMETERS
Simulant
Test Conditions
Amount
Sample Area/Simulant
Volume Ratio
Simulant
Test Conditions
Amount
Sample Area/Simulant
Volume Ratio
Simulant
Test Conditions
Amount
Sample Area/Simulant
Volume Ratio
Simulant
Test Conditions
Amount
Sample Area/Simulant
Volume Ratio
RESULT
Ethanol 10%
4h; 100°C
<1
0,3
Acetic Acid 3%
4h; 100°C
<1
0,3
Ethanol 95%
7h; 60°C
1,3
0,3
Isoctane
3h; 60°C
<1
0,3
U.M.
mg/dm2
dm2/dL
mg/dm2
dm2/dL
mg/dm2
dm2/dL
mg/dm2
dm2/dL
LIMITS
10
10
10
10
LQ
1
1
1
1
NOTES
LAB
ITA
ITA
ITA
ITA
ITA
ITA
ITA
ITA
ITA
ITA
ITA
ITA
ITA
ITA
ITA
ITA
Heavy Metals Migration
Council of Europe Resolution
cm/res(2013)9 +Reg. CE
1935/2004
01
Simulant
Test Conditions
Barium
Cobalt
Copper
Iron
Manganese
Zinc
Lithium
Alluminium
Acetic acid 3%
10 days; 40°C
< 0,1
< 0,04
<1
<5
< 0,1
< 2,5
< 0,1
< 0,1
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
1
0,05
5
48
0,6
5
0,6
1
0,1
0,04
1
5
0,1
2,5
0,1
0,1
ITA
ITA
ITA
ITA
ITA
ITA
ITA
ITA
ITA
ITA
PAA Promary Aromathic Amine
Reg. 10/2011 EC GU n° L12/1 +
Reg. CE 1935/2004
01
Simulant
Test Conditions
PAA Sum of Primary
Aromatic Amines
Acetic acid 3%
4 h; 100°C
< 0,01
mg/kg
0,01
0,01
ITA
ITA
ITA
Dyes Migration
D.M 34 of 21.3.73 and
Amendments + Reg. CE 1935/2004
01
Simulant
Test Conditions
Optical Trasmittance
Simulant
Test Conditions
Optical Trasmittance
Simulant
Test Conditions
Optical Trasmittance
Ethanol 10%
4h; 100°C
98
Acetic Acid 3%
4h; 100°C
98
Ethanol 20%
4h; 100°C
97
T%
T%
T%
>95
>95
>95
ITA
ITA
ITA
ITA
ITA
ITA
ITA
ITA
ITA
Intertek Italia S.p.a.
Administrative Office Via Miglioli, 2/A 20063 Cernusco Sul Naviglio (MI)
Operational Office Via di Stagno 17 F/G 50055 Lastra a Signa (FI)
Tel. 0039055790873 Fax 0039055791198
page
3 di 4
Rapporto di prova del trattamento interno alimentare Polywarm
®
in
conformità al D.M. nr. 174 del 06/04/04.
Certificazione di conformità Polywarm
®
secondo EN 16421.
Certificato di conformità POLYWARM
®
secondo WRAS.
Certificazione di conformità Polywarm
®
secondo il NIZP - Istituto
Nazionale di Igiene Pubblica - Polonia .