Aimer 3 Constant Current

Ø 80

50

1

0

0

Optic Spot 10o

IP

IP

66

67

175°

10°

2000 mm

IK

07

LED INCL

Sorgente a LED inclusa.

Alimentazione elettrica

remota 350/500 mA ON/OFF

e dimmerabile 1-10V o DALI

da ordinare separatamente.

Connessione in serie. Dotato

di spezzone di cavo uscente

in neoprene di 2000 mm e kit

con connettori crimp e guaina

termorestringente adesiva per

connessione a tenuta stagna.

Staffa di fissaggio inclusa. Vetro

trasparente extrachiaro.

Picchetto per installazione

a terra da ordinare

separatamente.

2200K disponibile su richiesta.

LED source included. Remote

power supply 350/500 mA

ON/OFF and dimmable 1-10V

or DALI. Must be ordered

separately. Serial connection.

Equipped with a 2000 mm

protruding section of neoprene

cable and a kit with crimpable

connectors and adhesive

heat-shrinkable sleeves that

guarantee the tightness of

the connection. Extraclear

transparent glass.

The metal nail for ground

installation needs to be ordered

separately.

2200K available on request.

Power Led: 3,3W@350mA - 331@350mA lm

≠ OUTPUT 270@350mA lm / 5,1W@500mA - 431@500mA lm ≠ OUTPUT 359@500mA lm - 2700K/CRI 80

3,3W@350mA - 359@350mA lm ≠ OUTPUT 293@350mA lm - 5,1W@500mA - 466@500mA lm ≠ OUTPUT 389@500mA lm - 3000K/CRI 80

3,3W@350mA - 373@350mA lm ≠ OUTPUT 304@350mA lm - 5,1W@500mA - 484@500mA lm ≠ OUTPUT 404@500mA lm - 4000K/CRI 80

2700K

FA1051071201

FA1051072206

FA1051071206

FA1051072212

FA1051071212

FA1051072218

FA1051071218

FA1051072230

FA1051071230

FA1051072233

FA1051071233

FA1051072270

FA1051071270

Optic Medium 30o

Power Led: 3,3W@350mA - 331@350mA lm ≠ OUTPUT

3,3W@350mA - 359@350mA lm ≠ OUTPUT

3,3W@350mA - 373@350mA lm ≠ OUTPUT

4000K

FA1051901201

FA1051901206

FA1051901212

FA1051901218

FA1051901230

FA1051901233

FA1051901270

274@350mA lm / 5,1W@500mA - 431@500mA lm ≠ OUTPUT 364@500mA lm - 2700K/CRI 80

297@350mA lm - 5,1W@500mA - 466@500mA lm ≠ OUTPUT 395@500mA lm - 3000K/CRI 80

308@350mA lm - 5,1W@500mA - 484@500mA lm ≠ OUTPUT 410@500mA lm - 4000K/CRI 80

4000K

FA1051901101

FA1051901106

FA1051901112

FA1051901118

FA1051901130

FA1051901133

FA1051901170

247@350mA lm / 5,1W@500mA - 431@500mA lm ≠ OUTPUT 329@500mA lm - 2700K/CRI 80

267@350mA lm - 5,1W@500mA - 466@500mA lm ≠ OUTPUT 357@500mA lm - 3000K/CRI 80

278@350mA lm - 5,1W@500mA - 484@500mA lm ≠ OUTPUT 371@500mA lm - 4000K/CRI 80

4000K

FA1051900001

FA1051900006

FA1051900012

FA1051900018

FA1051900030

FA1051900033

FA1051900070

3000K

90o

60o

30o

90o

60o

3536 cd

30o

m

1.00

2.00

3.00

4.00

5.00

=7.2 ̊+ 7.2 ̊

500 mA

Max Med

3536 2251

884 563

393 250

221 141

141 90

=7.3 ̊+ 7.3 ̊

α

β

FA1051072201

@ 3000K

2700K

FA1051071101

FA1051072106

FA1051071106

FA1051072112

FA1051071112

FA1051072118

FA1051071118

FA1051072130

FA1051071130

FA1051072133

FA1051071133

FA1051072170

FA1051071170

Optic Flood 50o

Power Led: 3,3W@350mA - 331@350mA lm ≠ OUTPUT

3,3W@350mA - 359@350mA lm ≠ OUTPUT

3,3W@350mA - 373@350mA lm ≠ OUTPUT

90o

60o

30o

90o

60o

1087 cd

30o

m

1.00

2.00

3.00

4.00

5.00

=16.5 ̊+ 16.5 ̊

α

500 mA

β

Max Med

1087 638

272 159

121 71

68

40

43

26

=16.5 ̊+ 16.5 ̊

FA1051072101

3000K

2700K

FA1051070001

FA1051072006

FA1051070006

FA1051072012

FA1051070012

FA1051072018

FA1051070018

FA1051072030

FA1051070030

FA1051072033

FA1051070033

FA1051072070

FA1051070070

FA1051072001

3000K

@ 3000K

90o

60o

30o

90o

60o

431 cd

30o

m

1.00

2.00

3.00

4.00

5.00

500 mA

β

Max Med

431 270

108 68

48

30

27

17

17

11

=26.9 ̊+ 26.9 ̊

=26.6 ̊+ 26.6 ̊

α

@ 3000K

* Numero massimo di apparecchi per alimentatore / Maximum number of luminaires per power supply.

Numero massimo di apparecchi

per alimentatore (Vin220÷240).

Dati indicativi da verificare

con le specifiche condizioni di

installazione.

Maximum number of luminaires

per power supply. (220÷240 V).

These data must be checked

taking into account the specific

installation conditions.

Acc. RF25754

2

Acc. RF25748

2

Acc. FA68

3

Acc. FA129

**5

Acc. FA184

**5

Acc. FA135

**2

Acc. FA218

**2

Acc. FA238.A

**3

Acc. FA239.A

**3

**La tensione ai capi del

sistema è in funzione del

numero di apparecchi

collegati in serie, attenersi

alle norme CEI 64-8.

**The voltage at the end

of the system depends

on the number of fixtures

connected in series, please

comply with CEI 64-8

standards.

765

Aimer