LINEA WY / PQH(R)Y-P Y(S)LM-A1
LINEA WR2 / PQH(R)Y-P Y(S)LM-A1
PQRY-P200YLM-A1
PQRY-P250YLM-A1
PQRY-P300YLM-A1
8
10
12
3 fasi 380-400-415V 50Hz
22,4
28,0
33,5
3,71
4,90
6,04
6,03
5,71
5,54
7,91
7,99
7,30
15,0~24,0
15,0~24,0
15,0~24,0
10,0~45,0
10,0~45,0
10,0~45,0
25,0
31,5
37,5
Potenza assorbita
kW
3,97
5,08
6,25
MODELLO
HP
Moduli
Giunto di accoppiamento
Alimentazione
Raffreddamento
Riscaldamento
Livello sonoro
3
Unità int. collegabili
Ø est. attacchi refr.
Acqua circolante
Dimensioni esterne (AxLxP)
Peso netto
Carica refr. R410A*4/CO2 Eq
DOUBLE PQHY-P400YSLM-A1
16
18
20
22
24
MODELLO
HP
Alimentazione
Raffreddamento
Riscaldamento
Livello sonoro
*3
Unità int. collegabili
Ø est. attacchi refr.
Acqua circolante
Dimensioni esterne (AxLxP)
Peso netto
Carica refr. R410A*
4
/CO
2
Eq
SINGLE
Tensione/Freq./Fasi
Capacità
*1
kW
14
16
18
20
22
24
3 fasi 380-400-415V 50Hz
40.0
45.0
50.0
56.0
63.0
69.0
MODELLO
HP
Moduli
Giunto di accoppiamento
Alimentazione
Raffreddamento
Riscaldamento
Livello sonoro
*3
Unità int. collegabili
Ø est. attacchi refr.
Acqua circolante
Dimensioni esterne (AxLxP)
Peso netto
Carica refr. R410A*
4
/CO
2
Eq
DOUBLE PQHY-P700YSLM-A1
28
30
32
34
36
V/Hz/n°
kW
Tensione/Freq./Fasi
V/Hz/n°
Potenza assorbita
EER
SEER
Campo operativo
di temperatura
Campo operativo
di temperatura
Capacitàmassima*
2
Potenza assorbita
COP
SCOP
Campo operativo
di temperatura
Interna BU
Acqua in circolo
°C
15,0~24,0
15,0~24,0
15,0~24,0
15,0~24,0
15,0~24,0
°C
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
kW
50,0
56,0
63,0
69,0
76,5
kW
7,94
8,97
10,16
11,31
12,75
COP
SCOP
4,90
4,61
4,55
Tensione/Freq./Fasi
Capacità
*1
Potenzaassorbita
EER
SEER
Campo operativo
di temperatura
Capacità massima*
2
Potenza assorbita
COP
SCOP
CMY-Y200VBK2
3 fasi 380-400-415V 50Hz
Capacitàmassima*
2
kW
45.0
50.0
56.0
63.0
69.0
76.5
Potenza assorbita
kW
7.53
8.37
9.79
11.43
12.27
14.51
COP
5.97
5.97
5.72
5.51
5.62
5.27
Campo operativo
di temperatura
Interna BS
Acqua in circolo
°C
Interna BS
°C
Acqua in circolo
°C
50~150% della capacità dell’unità esterna
Interna BU
Acqua in circolo
°C
°C
kW
50,0
56,0
63,0
69,0
76,5
kW
7,94
8,97
10,16
11,31
12,75
10.0~45.0
10.0~45.0
PQHY-P200YLM-A
PQHY-P200YLM-A
PQHY-P250YLM-A
PQHY-P200YLM-A
PQHY-P250YLM-A
PQHY-P250YLM-A
CMY-Y100VBK3
3 fasi 380-400-415V 50Hz
PQHY-P300YLM-A
PQHY-P250YLM-A
PQHY-P300YLM-A
PQHY-P300YLM-A
V/Hz/n°
kW
PQHY-P350YLM-A
PQHY-P350YLM-A
PQHY-P400YLM-A
PQHY-P350YLM-A
5.60
5.60
5.38
5.01
5.02
4.76
7,34
7,31
6,56
6,25
6,84
6,84
15.0~24.0
15.0~24.0
15.0~24.0
15.0~24.0
15.0~24.0
15.0~24.0
10.0~45.0
10.0~45.0
10.0~45.0
10.0~45.0
10.0~45.0
10.0~45.0
PQHY-P450YSLM-A1
PQHY-P500YSLM-A1
PQHY-P550YSLM-A1
PQHY-P600YSLM-A1
kW
45,0
50,0
56,0
63,0
69,0
kW
7,70
8,78
10,12
11,55
12,84
5,84
5,69
5,53
5,45
5,37
Capacità*
1
Potenza assorbita
EER
SEER
-
-
-
-
-
Interna BU
Acqua in circolo
°C
6,29
6,24
6,20
6,10
6,0
-
-
-
-
-
15,0~27,0
15,0~27,0
15,0~27,0
15,0~27,0
15,0~27,0
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
°C
10,0~45,0
dB(A)
46
Modalitànormale
dB(A)
49
50
51
55
57
Capacità totale
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
Portata nominale
Range operativo portata
Calo di pressione
Volume dello scambiatore
m
3
/h
5,76
3,0~7,2
kPa
24
l
5,0
mm
1100 x 880 x 550
kg
172
kg/Tons
5,0 /10,44
PQRY-P350YLM-A1
PQRY-P400YLM-A1
5,76
3,0~7,2
24
5,0
1100 x 880 x 550
172
5,0 /10,44
PQRY-P500YLM-A1
5,76
3,0~7,2
24
5,0
1100 x 880 x 550
172
5,0 /10,44
Modello/Quantità
Liquido
Gas
Portatanominale
m3/h
5,76+5,76
5,76+5,76
5,76+5,76
5,76+5,76
5,76+5,76
Range operativo portata
Calo di pressione
Volume dello scambiatore
3+3~7,2+7,2
24+24
5,0+5,0
1100 x 880 x 550
1100 x 880 x 550
174+174
5,0+5,0 /20,88
3+3~7,2+7,2
24+24
5,0+5,0
1100 x 880 x 550
1100 x 880 x 550
174+174
5,0+5,0 /20,88
3+3~7,2+7,2
24+24
5,0+5,0
1100 x 880 x 550
1100 x 880 x 550
174+174
5,0+5,0 /20,88
3+3~7,2+7,2
24+24
5,0+5,0
1100 x 880 x 550
1100 x 880 x 550
174+174
5,0+5,0 /20,88
3+3~7,2+7,2
24+24
5,0+5,0
1100 x 880 x 550
1100 x 880 x 550
174+174
5,0+5,0 /20,88
mm
kPa
l
mm
kg
kg/Tons
P15~P250/1~34
15,88
28,58
P15~P250/1~39
15,88
28,58
P15~P250/1~43
15,88
28,58
P15~P250/2~47
15,88
28,58
P15~P250/2~50
15,88
28,58
PQHY-P750YSLM-A1
PQHY-P800YSLM-A1
PQHY-P850YSLM-A1
PQHY-P900YSLM-A1
PQHY-P400YLM-A
PQHY-P400YLM-A
5,43
5,43
5,43
5,32
5,21
-
-
-
-
-
15,0~24,0
15,0~24,0
15,0~24,0
15,0~24,0
15,0~24,0
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
V/Hz/n°
kW
80,0
85,0
90,0
96,0
101,0
kW
14,73
15,64
16,57
18,03
19,38
Riscaldamento
Livello sonoro
*3
Unità int. collegabili
Ø est. attacchi refr.
Acqua circolante
Dimensioni esterne (AxLxP)
Peso netto
Carica refr. R410A*
4
/CO
2
Eq
6,29
6,24
6,20
6,10
6,0
-
-
-
-
-
15,0~27,0
15,0~27,0
15,0~27,0
15,0~27,0
15,0~27,0
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
10,0~45,0
P15~P250/1~35
P15~P250/1~40
P15~P250/1~45
P15~P250/1~50
P15~P250/2~50
P15~P250/2~50
°C
Modalitànormale
dB(A)
55
55
55
56
57
Range operativo portata
Calo di pressione
Volume dello scambiatore
4.5~11.6
kPa
44
l
5
mm
1450 x 880 x 550
kg
216
kg/Tons
6.0 /12.53
4.5~11.6
44
5
1450 x 880 x 550
216
6.0 /12.53
4.5~11.6
44
5
1450 x 880 x 550
216
6.0 /12.53
4.5~11.6
44
5
1450 x 880 x 550
216
6.0 /12.53
6.0~14.4
45
10
1450 x 880 x 550
246
11.7/24.43
6.0~14.4
45
10
1450 x 880 x 550
246
11.7/24.43
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
50~130% della capacità
dell’unità esterna
Modello/Quantità
Liquido/Gas
Portatanominale
m
3
/h
7,20+7,20
7,20+7,20
7,20+7,20
7,20+7,20
7,20+7,20
Range operativo portata
Calo di pressione
Volume dello scambiatore
4,5+4,5~11,6+11,6
kPa
44+44
l
5,0+5,0
4,5+4,5~11,6+11,6
44+44
5,0+5,0
1450 x 880 x 550
1450 x 880 x 550
217+217
6,0+6,0 /25,06
4,5+4,5~11,6+11,6
44+44
5,0+5,0
1450 x 880 x 550
1450 x 880 x 550
217+217
6,0+6,0 /25,06
4,5+4,5~11,6+11,6
44+44
5,0+5,0
1450 x 880 x 550
1450 x 880 x 550
217+217
6,0+6,0 /25,06
4,5+4,5~11,6+11,6
44+44
5,0+5,0
1450 x 880 x 550
1450 x 880 x 550
217+217
6,0+6,0 /25,06
*
1
Condizioni di raffreddamento nominali: interno 27°C BS / 19°C BU. Temperatura acqua 30°C Lunghezza tubazioni 7.5m, dislivello 0m.
*
2
Condizioni di riscaldamento nominali: interno 20°C BS. Temperatura acqua 20°C Lunghezza tubazioni 7.5m, dislivello 0m.
*
3
Valori misurati in camera anecoica.
*
4
GWP di HFC R410A pari a 2088 secondo regolamento 517 / 2014
I dati di SEER e SCOP sono basati in conformità allo standard di misura EN14825
*
1
Condizioni di raffreddamento nominali: interno 27°C BS / 19°C BU. Temperatura acqua 30°C Lunghezza tubazioni 7.5m, dislivello 0m.
*
2
Condizioni di riscaldamento nominali: interno 20°C BS. Temperatura acqua 20°C Lunghezza tubazioni 7.5m, dislivello 0m.
*
3
Valori misurati in camera anecoica.
*
4
GWP di HFC R410A pari a 2088 secondo regolamento 517 / 2014
I dati di SEER e SCOP sono basati in conformità allo standard di misura EN14825
60
61
P15~P250/2~50
mm
19,05/34,93
19,05/34,93
19,05/34,93
19,05/41,28
19,05/41,28
mm
1450 x 880 x 550
1450 x 880 x 550
kg
217+217
kg/Tons
6,0+6,0 /25,06
P15~P250/2~50
P15~P250/2~50
P15~P250/2~50
P15~P250/2~50
PQHY-P450YLM-A
PQHY-P400YLM-A
PQHY-P450YLM-A
PQHY-P450YLM-A
Campo operativo
di temperatura
Interna BU
°C
Acqua in circolo
°C
MODELLO
HP
Alimentazione
Raffreddamento
EER
SEER
SINGLE
PQRY-P450YLM-A1
PQRY-P550YLM-A1
PQRY-P600YLM-A1
°C
Capacitàmassima
*2
kW
Campo operativo
di temperatura
Interna BU
Esterna BS
°C
15,0~27,0
15,0~27,0
10,0~45,0
48
50~150% della capacità dell’unità esterna
15,0~27,0
10,0~45,0
54
50~150% della capacità dell’unità esterna
6,29
6,20
6,00
Modalità normale
Capacità totale
Modello/Quantità
P15~P250/1~20
P15~P250/1~25
P15~P250/1~30
Liquido
mm
15,88
19,05
19,05
Gas
19,05
22,2
22,2
Tensione/Freq./Fasi
Capacità*
1
Potenzaassorbita
kW
7.14
8.03
9.29
11.17
12.54
14.49
SCOP
4,29
4,25
4,17
4,04
3,77
3,51
15.0~27.0
15.0~27.0
15.0~27.0
15.0~27.0
10.0~45.0
10.0~45.0
10.0~45.0
10.0~45.0
Campo operativo
di temperatura
Interna BU
°C
15.0~27.0
15.0~27.0
Esterna BS
°C
Modalitànormale
dB(A)
52
52
54
54
56.5
56.5
50~150% della capacità 50~150% della capacità 50~150% della capacità 50~150% della capacità 50~150% della capacità 50~150% della capacità
dell’unità esterna
dell’unità esterna
dell’unità esterna
dell’unità esterna
dell’unità esterna
dell’unità esterna
Modello/Quantità
Liquido
mm
22.2
22.2
22.2
22.2
22.2
22.2
Gas
28.58
28.58
28.58
28.58
28.58
34.93
Portatanominale
m
3
/h
7.20
7.20
7.20
7.20
11.52
11.52
Capacità totale